TOA Electronics C-RM500 operating instructions Fixed camera

Page 45

 

 

 

 

 

 

 

 

 

 

RS-232C reverse cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Female D-sub 9-pin connector to Female D-sub 9-pin connector

C-RM500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Camera control terminal

 

 

 

 

 

Switcher control terminal

Alarm output terminal

 

 

GND

 

 

 

 

 

 

 

RS-232C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixed camera

Shielded twisted-pair cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-switcher

 

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm I/O

 

 

 

 

 

 

 

 

Camera input/output

 

 

 

 

RS-232C

 

 

 

 

1

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

Monitor output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Corresponding to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the fixed camera A

A

1

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

B

2

Camera control

 

Alarm input

 

 

 

 

 

 

 

 

 

A

3

cable

 

 

 

 

cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

4

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

Corresponding to

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the fixed camera B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

Combination camera

 

 

 

 

 

 

5, 10

 

Sensor

 

 

 

 

Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Camera control

 

Alarm input

 

 

 

 

 

 

 

 

Monitor TV

 

3

cable

 

 

 

 

cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

Combination camera

 

 

 

 

 

 

5, 10

 

Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The use of each camera's alarm input permits connection of 8 sensors for each camera.

*Connect this cable only when "2. LEVEL" is selected in the unit's "Alarm signal" setting. (Refer to p. 35.) Connect the C-RM500's alarm output corresponding to the Combination Camera address to the Multi- Switcher's alarm input, while leaving other output terminals not corresponding to any Camera address unconnected.

45

Image 45
Contents Operating Instructions Remote ControllerTable of Contents Settings Safety Precautions Functions General DescriptionEquipment Which Can Be Controlled with the C-RM500 About the Camera Control TerminalTop Nomenclature and FunctionsDefroster key/Indicator *3 Lens speed key / Indicator *3Auxiliary contact key / Indicator *3 Auto key / Indicator *3Rear Operating the Camera OperationP E R N U a LF R O S T E R X I L I a R Y S WActivating the automatic functions T OActivating the zoom function Activating the focus functionO S I T I O N T O F O C U SChanging the lens speed Activating the auto-focus functionMonitor Display When confirming the camera number and operating its displayA N N E L C a L L Operation keysResetting individual freeze displays Simultaneously resetting all freeze displaysUsing the abbreviated numbers Using the Function keysU N C T I O N K E Y E TH a N N E L E G M E N TViewing full-screen displays Monitor screen Group E G M E N T E G S E Q Q U E N C EViewing sequential displays Sequential full-screen viewing Sequential 4-segment split-screen viewingAlarm H O L D Alarm Hold and ResetSetting Items and Their Descriptions SettingsKeys to be used in setting operations Operating Keys and Display ScreenLCD screen display S S W O R D Basic Setting OperationsE R a T I O N M O D E T O R E T U R NOperation mode Setting the FunctionsSetting contents E R a T I O N M O D E 1 . M a S T E RI T C H E R Switchers6 I N P U T M a R TN T a C T E L E C T C HContact T O R E T U R N 1 . O N Automatic resetT O T U R N E CR a C E 2 P O S Home position selector terminal operation settingsR a C E Home positionM E R a S P E E D4 0 M O T EBuzzer I T I a L S C R E E N 1 . F U L LZ Z E R 1 . O N Initial screenChannel designation I T I a L C H a N N E LM E R a Alarm 1 . O N N S O R Alarm 1 . O NSensor alarm Camera alarmCamera check Camera alarm preset Alarm S I G N a L 1 . E D G E Alarm signalAlarm time Alarm F U N C T I O N 1 . S E Q Alarm H O L D 1 . K E YAlarm hold M 1 N C T I O N K E YM 1 5 P O S 1 2 N C T I O N K E Y a a U T O P a NSetting the cameras alarm contact output M 2Abbreviation 2 3 P 0 S E C 0 S E CTour sequence Press the Menu key to display the menu screenPassword M E R a M E N U C HCamera menu Connections System ExamplesExample Example Connected Camera Termination Switch Setting Connection to Combination CamerasConnection cables Connection to the Multi-Switchers RS-232C Terminal Fixed camera Connection to the Smart Switchers RS-232C Terminal Shielded twisted-pair cable RS-232C reverse cable RM500 Slave Speed Switcher Connection When Controlling the System from 2 LocationsAlarm Output/Control Input Terminal Connections Assembling D-sub connectors onto cables Specifications AccessoriesModifications 133-12-743-6E