TOA Electronics C-RM500 Connection to Combination Cameras, Connection cables

Page 43

7.2. Connection to Combination Cameras

Connect the Combination camera's control cable to the unit's Camera Control terminal, making sure to match their polarities.

C-RM500 (Operation mode: "MASTER")

Camera control terminal

GND

Shielded twisted-pair cable

A

 

1

 

B

 

2

 

A

 

3

 

 

B4

5

Video output cable

Camera control cable

 

 

 

Monitor TV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combination camera

[Connection cables]

Recommended cable type: CPEV-S type (shielded twisted-pair cable) thicker than 0.65 mm in diameter.

The maximum cable distance between the unit and the Combination camera is 1.2 km when connected in a matched pair. If multiple cameras are connected to a system, the maximum distance between connected equipment is 1.2 km in total.

Remote Controller

C-RM500

a

Combination

camera

b

Combination

camera

c

Combination

camera

a + b + c < 1.2 km

[Connected Camera Termination Switch Setting]

Make sure that the termination switches of the cameras connected to the system are set as follows.

Cameras other than the last connected camera: Termination switch OFF

Last connected camera:

Termination switch ON

Remote Controller

C-RM500

Combination

camera

Terminal switch

OFF

Combination

camera

Terminal switch

OFF

Combination

camera

Terminal switch

ON

43

Image 43
Contents Operating Instructions Remote ControllerTable of Contents Settings Safety Precautions About the Camera Control Terminal General DescriptionFunctions Equipment Which Can Be Controlled with the C-RM500Top Nomenclature and FunctionsAuto key / Indicator *3 Lens speed key / Indicator *3Defroster key/Indicator *3 Auxiliary contact key / Indicator *3Rear Operating the Camera OperationX I L I a R Y S W N U a LP E R F R O S T E RActivating the focus function T OActivating the automatic functions Activating the zoom functionActivating the auto-focus function T O F O C U SO S I T I O N Changing the lens speedOperation keys When confirming the camera number and operating its displayMonitor Display A N N E L C a L LResetting individual freeze displays Simultaneously resetting all freeze displaysE T Using the Function keysUsing the abbreviated numbers U N C T I O N K E YE G M E N T H a N N E LViewing full-screen displays Monitor screen Group E G M E N T Sequential 4-segment split-screen viewing Q U E N C EE G S E Q Viewing sequential displays Sequential full-screen viewingAlarm H O L D Alarm Hold and ResetSetting Items and Their Descriptions SettingsOperating Keys and Display Screen Keys to be used in setting operationsLCD screen display T O R E T U R N Basic Setting OperationsS S W O R D E R a T I O N M O D EE R a T I O N M O D E 1 . M a S T E R Setting the FunctionsOperation mode Setting contentsM a R T SwitchersI T C H E R 6 I N P U TE L E C T C H N T a C TContact E C Automatic resetT O R E T U R N 1 . O N T O T U R NHome position Home position selector terminal operation settingsR a C E 2 P O S R a C EM O T E S P E E DM E R a 4 0Initial screen I T I a L S C R E E N 1 . F U L LBuzzer Z Z E R 1 . O NChannel designation I T I a L C H a N N E LCamera alarm N S O R Alarm 1 . O NM E R a Alarm 1 . O N Sensor alarmCamera check Camera alarm preset Alarm signal Alarm S I G N a L 1 . E D G EAlarm time Alarm H O L D 1 . K E Y Alarm F U N C T I O N 1 . S E QAlarm hold N C T I O N K E Y a a U T O P a N N C T I O N K E YM 1 M 1 5 P O S 1 2M 2 Setting the cameras alarm contact outputAbbreviation Press the Menu key to display the menu screen 0 S E C2 3 P 0 S E C Tour sequenceM E R a M E N U C H PasswordCamera menu System Examples ConnectionsExample Example Connection to Combination Cameras Connected Camera Termination Switch SettingConnection cables Connection to the Multi-Switchers RS-232C Terminal Fixed camera Connection to the Smart Switchers RS-232C Terminal Shielded twisted-pair cable RS-232C reverse cable RM500 Slave Speed Switcher Connection When Controlling the System from 2 LocationsAlarm Output/Control Input Terminal Connections Assembling D-sub connectors onto cables Accessories SpecificationsModifications 133-12-743-6E