Using the Variable Control Voice Actuator (VCVA)
When the microphone senses that sounds have reached a preset actuation volume level, the
2
1 Set the VCVA in the menu to ON (☞ P.37- 38).
2 Press the REC button to start recording. When the sound volume is lower than the preset
2 actuation sound level, recording automatically stops after 1 second approximately, and “STANDBY” flashes on the display. The record/play indicator lamp glows when recording starts and flashes when recording pauses.
AUTHOR A |
1H25M01S |
STANDBY |
Using the Variable Control
Adjust the Start/Stop Actuation Level
Voice
2 1
1 Press the FOLDER/MENU button during recording.
The VCVA level screen is displayed.
2 Press the FF or REW button to adjust the actuation level.
The VCVA level can be set to any of 15 different values. The higher the value is, the more sensitive the recorder can react to sounds. At the highest value, even the faintest sound will activate recording. The VCVA actuation level can be adjusted according to the ambient (background) noise.
aStart level (varies according to the sound
volume being recorded)
bLevel meter (moves to the right/left according to the set level)
|
|
| AUTHOR A | |||
a |
|
|
| 1H25M01S | ||
|
| VCVA LEVEL 05 | ||||
b |
|
|
|
|
| |
|
|
|
|
|
|
|
Actuator (VCVA)
..............................................................................................................................................................
Notes
•The start/stop actuation level also varies depending on the selected microphone sensitivity mode (☞ P.27).
•To ensure successful recordings, prior testing and adjustment of the start/stop actuation level is recommended. 29