GE DVMRe user manual RS485 Connector, RJ-45 Pin Configuration For RS485 Port, Ethernet Port

Page 14

Pin 1: Not Used.

Pin 2: Audio Out.

Pin 3: Ground.

Pin 4: Audio In.

Pin 5: Ground.

Pin 6: Not Used.

Pin 7: Ground.

Pin 8: Not Used.

Pin 9: Ground.

GND: Ground.

RS485 Connector

Shields are grounded at one end, preferably at the DVMRe Triplex.

See section 3.17 for information about configuring the RS485 network address settings in the menu system.

1

6

2

7

3

8

4

9

5 GND

Accessory PCB

Wire Type: #24 AWG, twisted pair with shield (2-wire)

Connector Type: RJ-45

Max. Cable Length: 3200 feet / 1000 meters

RJ-45 Pin Configuration For RS485 Port

 

Pin

 

 

Use

 

 

 

Pin

 

 

Use

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5 6 7 8

 

 

 

1

 

 

Ground (Shield)

 

 

5

 

 

Not Connected

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

Not Connected

 

 

6

 

 

Network -VE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

Network +VE

 

 

7

 

 

Ground (Shield)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

Not Connected

 

 

8

 

 

Not Connected

 

RJ-45 socket on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

back panel.

Ethernet Port

The cable connection configuration depends on your network configuration:

For a DVMRe Triplex that connects directly to a Hub or Switch, use a straight through connection.

For a DVMRe Triplex that connects directly to a PC, use a cross over connection.

Consult with your MIS personnel for the specific type of configuration. See section 3.17 for information about configuring the ethernet settings in the menu system.

Wire Type: Cat 5

Connector Type: RJ-45

Max. Cable Length: 100 meters / 328 ft.

Min. Cable Length: 6 feet / 1.8 meters

Hub Wiring Configuration: Straight Through

PC Wiring Configuration: Cross Over

0150-0193F

14

Kalatel DVMRe Triplex

Image 14
Contents Kalatel DVMRe Triplex Page Important Information Contents Searching AlarmsRS232 Remote Control Protocol WebBrowser11.1 11Warranty and Service10.2 Scheduled Macro Table 11.2DVMRe Triplex Overview Products Featured In This ManualFeatures Product DescriptionPasswords Default Passwords Four-Channel UnitsUnpacking Installation EnvironmentPackage Contents Ten and Sixteen-Channel UnitsAssociated Equipment Back PanelComposite Monitor Output Alarm I/O PortCamera Inputs Monitor OutputNormally Open and Normally Closed Connections Alarm InputAlarm PCB AUX Port Alarm Relay OutputExternal Alarm Acknowledge Input Voltage 30V MaxEthernet Port RS485 ConnectorRJ-45 Pin Configuration For RS485 Port Scsi Port RJ-45 Pin Configuration For Ethernet PortIeee 1394 Firewire Port Gender on unit FemalePower-Up Check Record And Playback Quality Minimum Recommended Menu SetupQuickInstall Main Menu Location Section Menu Item Manual Front Panel DMVRe Triplex Basic OperationsPrincipal Operating Modes Play Forward Button Begins PlaybackLive Viewing Playback Stop Button Stop PlaybackSearching Recorded Data Sequence Button Number ButtonRecord Button RecordingMonitor Displays During Recording Active Cameos Entering Active Cameo ModeDisplay Options Available Multiscreen DisplaysSelecting Cameras Returning To The Default Sequence ListSequencing Dwell TimeStatus Indicators On-screen IndicatorsChanging Position And Color Of Title And Status Indicators Sequencing In CameosStatus Display Box Triplex ModeConditional Indicators ATM/POS Text DisplayStop Reverse Play Button Jog / Shuttle Freeze Button Stop ButtonZoom and Function Button Print Image FeatureNumber Button Sequence Button Conditions Printer SetupEquipment Menu Notation In This Manual Accessing The Menu SystemMenu System Overview Available MenusMenu Shortcuts Menus In This ManualNavigating The Menu System Opening the Drop Down Menus Rotate the JogMain Menu Overview Main MenuTime/Date Main Menu → Time/Date → Time / Date DisplayMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Set Date FormatMain Menu → Time/Date → Set Date Main Menu → Time/Date → Network Time Setup Main Menu → Time/Date → Set RegionMain Menu → Sequencing → Fullscreen Dwell RecordMain Menu → Sequencing → Multiscreen Dwell Main Menu → Record → Record Quality Main Menu → Record → Record TimerMain Menu → Record → Event Settings Record Quality Picture Quality Disk Space NeededMain Menu → Record → Timelapse Record Rate Camera 1 0.40 pps 2.5 sppMain Menu → Record → Event Record Rate Main Menu → Record → Activity Record RateMain Menu → Record → Alarm Record Rate Days 16 h TotalNo Overwrite Main Menu → Record → Record ModeMain Menu → Record → Disk Maintenance Write OnceMain Menu → Alarms → Input Configuration AlarmsMain Menu → Record → Auto Delete Mode Should not be the only alarm device on siteMain Menu → Alarms → Alarm Latch Main Menu → Alarms → Alarm ActionMain Menu → Alarms → Alarm History Main Menu → Alarms → Alarm Record ModeMain Menu → Alarms → Enable / Disable ∙ Enable All ∙ Disable AllMain Menu → Alarms → Relay Configuration Main Menu → Alarms → Link To a MacroMain Menu → Alarms → Fullscreen Alarm Main Menu → Alarms → Buzzer SetupMain Menu → Alarms → Notification Main Menu → Alarms → Videoloss ActionMain Menu → Alarms → Pre Alarm Duration Email Notification SetupTCP/IP Notification Setup EnableMain Menu → Macro → Macro Record Main Menu → Alarms → Archive AlarmsMacro Macro Excluded Features Main Menu → Macro → Timed Macro StartRunning a Macro Motion DetectionMain Menu → Macro → Edit Submacro Daylight Savings Time Alternate MethodMain Menu → Motion Detection → Setup Parameters Main Menu → Motion Detection → Enable/Disable DetectionIndividual Enable Menu Activity Detection SetupActivity Grid Setup Screen Intrusion Detection SetupMain Menu → Motion Detection → Setup Active Zones Sensitivity Scope Camera SetupMain Menu → Camera Setup → Camera Titles Main Menu → Motion Detection → Indicate DetectionEdit Titles Main Menu → Camera Setup → AGCTitles Display Camera Title Edit MenuPower Up Disable Main Menu → Camera Setup → Camera DisableIndividual Disable Auto Disable NowMain Menu → Archive Setup → Port Select Archive SetupMain Menu → Camera Setup → Camera Scope Luminance HistogramAudio Setup CommunicationsPots Setup PortMain Menu → Communications → RS485 Main Menu → Communications → Ethernet SettingsBaud Rate Changing the Installer or Operator Passwords Factory SettingsReturn To Factory Defaults Front Panel LockActivate The Ethernet Password QuickInstall MenuEthernet Password Deactivate The Ethernet PasswordOperator Menu Overview Operator MenuSystemView Menu SystemView Menu OverviewView Screens Alarm ActionCamera ∙ Enable/Disable 1 = Enabled, 0 = Disabled View Screen∙ Target Size 1 through Record Timer∙ Relay Output None, 1, 2, 1+2 ∙ Link to Event Yes or No Record Rate∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off ∙ Network Address∙ Keyboard Lock On or Off ∙ Record Lock On or Off Alarm Output AlarmsAlarm Input Alarm AcknowledgeLive Alarms Displays Alarm Operations During PlaybackMonitor-B Display During Alarm Channel UnitsRecorded Alarms Alarm History BoxSearching For Recorded Alarms Searching Search Menu OverviewSearch Button Disk Analysis ScreenQuick Archive to CD Motion Search Function ButtonSearch Filters Selecting Search ParametersSearch Results Activate SearchTo access the web interface WebBrowser∙ The Main Viewing Area The large blue area WaveBrowser Overview and ControlsMain Viewing Area Drop Down Volume List Box Button PanelName Code Description Example DVMRe Triplex WaveLinkFunctionality Email Links Connections Technical SpecificationsGeneral VideoPart Numbers AudioMotion Detection Message Structure Alarm/Event FieldAlarm/Event Message TypeAlarm/Event Description Front Panel Button EmulationData Structure Configuration and Status Data structureMacro Description Number Macro TablesMacro Functions Table Scheduled Macro Table Event Day Time Macro to RunFactory Address Warranty and ServiceFactory Service Warranty and Return Information Advance Replacement Policy0150-0193F