GE DVMRe user manual ∙ Network Address, ∙ Keyboard Lock On or Off ∙ Record Lock On or Off

Page 64

View Screen 7

Record Mode: No Overwrite, Write Once, or Continuous.

Indicate Detection: On or Off.

Global Buzzer: On or Off.

Live Alarm Buzzer: On or Off.

Video Loss Buzzer: On or Off.

Playback Buzzer: On or Off.

Relay 1: Normally Open or Normally Closed.

Relay 2: Normally Open or Normally Closed.

Alarm Latch: T = Transparent, L = Latched, TO (020) = Timed Out (Time)

Alarm Record Mode: Interleaved, Exclusive, or No Change.

Full Screen Alarm: Yes or No. This feature is not selectable on the 4-Channel units. 4ch = Yes.

Global Alarm Record Rate: In pictures per second (pps). 30 pps

Pre Alarm Duration: In seconds. 001

Archive Alarm: Enable or Disable.

View Screen 8

Auto Disable: On or Off.

Background Archive: On or Off.

Monitor Setup: Single or Dual.

Baud Rate Port 1: 1200,1400, 4800, 9600, 19200, 38400, and 57600.

Baud Rate Port 2: 1200,1400, 4800, 9600, 19200, 38400, and 57600.

Network Address: 001-005.001

Ethernet: Enable or Disable.

POTS: Enable or Disable.

Language: English, German, or French.

Keyboard Lock: On or Off.

Record Lock: On or Off.

Regional Settings: Off, USA, EUR, and AUS.

Time Zone: GMT+00:00

QuickWave CD Write: On or Off.

View Screen 9

NTP Update Interval: Enable or Disable.

NTP Primary Server: 3. 37. 8. 26

NTP Backup Server: 0. 0. 0. 0

Subnet Mask: 255.255.254. 0

Gateway: 3. 18.172. 1

DHCP: Enable or Disable.

Name Service: WINS or Disable.

Primary Name Server: 3. 18.173. 12

Backup Name Server: 3. 18.173. 13

Print Server: 3. 18.173. 11

TCP MTU Size: Standard, 1200, and 1400.

0150-0193F

64

Kalatel DVMRe Triplex

Image 64
Contents Kalatel DVMRe Triplex Page Important Information Contents Alarms RS232 Remote Control ProtocolSearching WebBrowser11Warranty and Service 10.2 Scheduled Macro Table11.1 11.2Products Featured In This Manual FeaturesDVMRe Triplex Overview Product DescriptionPasswords Default Passwords Four-Channel UnitsInstallation Environment Package ContentsUnpacking Ten and Sixteen-Channel UnitsAssociated Equipment Back PanelAlarm I/O Port Camera InputsComposite Monitor Output Monitor OutputAlarm PCB Alarm InputNormally Open and Normally Closed Connections Alarm Relay Output External Alarm Acknowledge InputAUX Port Voltage 30V MaxRJ-45 Pin Configuration For RS485 Port RS485 ConnectorEthernet Port RJ-45 Pin Configuration For Ethernet Port Ieee 1394 Firewire PortScsi Port Gender on unit FemalePower-Up QuickInstall Main Menu Location Section Menu Item Manual Minimum Recommended Menu SetupCheck Record And Playback Quality DMVRe Triplex Basic Operations Principal Operating ModesFront Panel Play Forward Button Begins PlaybackLive Viewing Playback Stop Playback Searching Recorded DataStop Button Sequence Button Number ButtonMonitor Displays During Recording RecordingRecord Button Entering Active Cameo Mode Display OptionsActive Cameos Available Multiscreen DisplaysReturning To The Default Sequence List SequencingSelecting Cameras Dwell TimeOn-screen Indicators Changing Position And Color Of Title And Status IndicatorsStatus Indicators Sequencing In CameosTriplex Mode Conditional IndicatorsStatus Display Box ATM/POS Text DisplayStop Reverse Play Button Jog / Shuttle Freeze Button Stop ButtonNumber Button Sequence Button Print Image FeatureZoom and Function Button Equipment Printer SetupConditions Accessing The Menu System Menu System OverviewMenu Notation In This Manual Available MenusMenus In This Manual Navigating The Menu SystemMenu Shortcuts Opening the Drop Down Menus Rotate the JogMain Menu Time/DateMain Menu Overview Main Menu → Time/Date → Time / Date DisplayMain Menu → Time/Date → Set Date Main Menu → Time/Date → Set Date FormatMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Network Time Setup Main Menu → Time/Date → Set RegionMain Menu → Sequencing → Multiscreen Dwell RecordMain Menu → Sequencing → Fullscreen Dwell Main Menu → Record → Record Timer Main Menu → Record → Event SettingsMain Menu → Record → Record Quality Record Quality Picture Quality Disk Space NeededMain Menu → Record → Timelapse Record Rate Camera 1 0.40 pps 2.5 sppMain Menu → Record → Event Record Rate Main Menu → Record → Activity Record RateMain Menu → Record → Alarm Record Rate Days 16 h TotalMain Menu → Record → Record Mode Main Menu → Record → Disk MaintenanceNo Overwrite Write OnceAlarms Main Menu → Record → Auto Delete ModeMain Menu → Alarms → Input Configuration Should not be the only alarm device on siteMain Menu → Alarms → Alarm Latch Main Menu → Alarms → Alarm ActionMain Menu → Alarms → Alarm Record Mode Main Menu → Alarms → Enable / DisableMain Menu → Alarms → Alarm History ∙ Enable All ∙ Disable AllMain Menu → Alarms → Link To a Macro Main Menu → Alarms → Fullscreen AlarmMain Menu → Alarms → Relay Configuration Main Menu → Alarms → Buzzer SetupMain Menu → Alarms → Videoloss Action Main Menu → Alarms → Pre Alarm DurationMain Menu → Alarms → Notification Email Notification SetupTCP/IP Notification Setup EnableMacro Main Menu → Alarms → Archive AlarmsMain Menu → Macro → Macro Record Macro Excluded Features Main Menu → Macro → Timed Macro StartMotion Detection Main Menu → Macro → Edit SubmacroRunning a Macro Daylight Savings Time Alternate MethodMain Menu → Motion Detection → Enable/Disable Detection Individual Enable MenuMain Menu → Motion Detection → Setup Parameters Activity Detection SetupMain Menu → Motion Detection → Setup Active Zones Intrusion Detection SetupActivity Grid Setup Screen Camera Setup Main Menu → Camera Setup → Camera TitlesSensitivity Scope Main Menu → Motion Detection → Indicate DetectionMain Menu → Camera Setup → AGC Titles DisplayEdit Titles Camera Title Edit MenuMain Menu → Camera Setup → Camera Disable Individual DisablePower Up Disable Auto Disable NowArchive Setup Main Menu → Camera Setup → Camera ScopeMain Menu → Archive Setup → Port Select Luminance HistogramAudio Setup CommunicationsPots Setup PortBaud Rate Main Menu → Communications → Ethernet SettingsMain Menu → Communications → RS485 Factory Settings Return To Factory DefaultsChanging the Installer or Operator Passwords Front Panel LockQuickInstall Menu Ethernet PasswordActivate The Ethernet Password Deactivate The Ethernet Password Operator Menu SystemView Menu Operator Menu Overview SystemView Menu OverviewAlarm Action Camera ∙ Enable/Disable 1 = Enabled, 0 = DisabledView Screens View ScreenRecord Timer ∙ Relay Output None, 1, 2, 1+2 ∙ Link to Event Yes or No∙ Target Size 1 through Record Rate∙ Keyboard Lock On or Off ∙ Record Lock On or Off ∙ Network Address∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off Alarms Alarm InputAlarm Output Alarm AcknowledgeAlarm Operations During Playback Monitor-B Display During AlarmLive Alarms Displays Channel UnitsSearching For Recorded Alarms Alarm History BoxRecorded Alarms Searching Search Menu OverviewQuick Archive to CD Disk Analysis ScreenSearch Button Motion Search Function ButtonSearch Filters Selecting Search ParametersSearch Results Activate SearchTo access the web interface WebBrowserMain Viewing Area WaveBrowser Overview and Controls∙ The Main Viewing Area The large blue area Drop Down Volume List Box Button PanelFunctionality DVMRe Triplex WaveLinkName Code Description Example Email Links Technical Specifications GeneralConnections VideoMotion Detection AudioPart Numbers Alarm/Event Field Alarm/EventMessage Structure Message TypeAlarm/Event Data Structure Front Panel Button EmulationDescription Configuration and Status Data structureMacro Functions Table Macro TablesMacro Description Number Scheduled Macro Table Event Day Time Macro to RunFactory Service Warranty and ServiceFactory Address Warranty and Return Information Advance Replacement Policy0150-0193F