GE DVMRe user manual Main Menu → Alarms → Archive Alarms, Main Menu → Macro → Macro Record

Page 47

 

 

 

 

 

TCP/IP Notification Setup

 

 

One or more of these

 

Notify Vidloss:

DISABLE

 

 

fields must be set to

 

Notify Alarm:

DISABLE

 

 

ENABLE to receive an

 

 

 

Notify Record:

DISABLE

 

 

 

 

 

 

email notification of

 

 

 

the selected event.

 

Notify Archive:

DISABLE

 

 

 

 

 

 

 

Notify Menu Access:

DISABLE

 

 

 

 

 

 

 

Notify Power Up:

DISABLE

 

 

 

 

 

 

 

Notify Connection:

DISABLE

 

 

The IP Addresses

 

 

 

 

Primary Host:

0.

0.

0.

0

 

 

 

Backup Host:

0.

0.

0.

0

of the PC on which

 

 

the WaveReader

 

Port:

1027

 

 

Software resides

 

Notification Interval (minutes): Immediate

 

 

 

 

 

 

 

 

 

 

 

 

[CANCEL]

[OK]

 

 

 

The Notification Interval can be set from 1 minute to 60 minutes, or immediately upon the event.

qMain Menu Alarms Archive Alarms

Selecting Enable from this menu will cause the unit to activate Relay 2 if a malfunction occurs while archiving.

Archive Alarm

Relay 2

ENABLE

3.12 Macro

A macro is a recorded sequence of keystrokes. The number of macros depends on the number of camera inputs (4, 10 or 16). Each macro can have up to 32 keystrokes.

Use this menu to:

Enter Macro Record mode.

Program a scheduled start time for a macro.

Edit the RS232 command string for each submacro.

Macro Record

Timed Macro Start

Edit Submacro

qMain Menu Macro Macro Record

Note: Do not attempt macro programming while the front panel is locked.

To begin recording a macro:

1.Select the macro number you wish to record, then press the Enter button. The unit will automatically exit the menu system and go to a starting point. Macro Record mode

is indicated as F and the Macro Number on-screen.

Macro Record

Select Macro

01

2.From this point, begin recording the desired keystroke sequence. Record up to 32 keystrokes. If 32 keystrokes are exceeded, the unit will end the macro recording automatically.

3.When finished programming, press the Function button then the Enter button to end the macro recording. A form is provided in section 10 to keep track of recorded macro functions.

0150-0193F

47

Kalatel DVMRe Triplex

Image 47
Contents Kalatel DVMRe Triplex Page Important Information Contents WebBrowser AlarmsRS232 Remote Control Protocol Searching11.2 11Warranty and Service10.2 Scheduled Macro Table 11.1Product Description Products Featured In This ManualFeatures DVMRe Triplex OverviewDefault Passwords Four-Channel Units PasswordsTen and Sixteen-Channel Units Installation EnvironmentPackage Contents UnpackingBack Panel Associated EquipmentMonitor Output Alarm I/O PortCamera Inputs Composite Monitor OutputNormally Open and Normally Closed Connections Alarm InputAlarm PCB Voltage 30V Max Alarm Relay OutputExternal Alarm Acknowledge Input AUX PortEthernet Port RS485 ConnectorRJ-45 Pin Configuration For RS485 Port Gender on unit Female RJ-45 Pin Configuration For Ethernet PortIeee 1394 Firewire Port Scsi PortPower-Up Check Record And Playback Quality Minimum Recommended Menu SetupQuickInstall Main Menu Location Section Menu Item Manual Play Forward Button Begins Playback DMVRe Triplex Basic OperationsPrincipal Operating Modes Front PanelLive Viewing Playback Sequence Button Number Button Stop PlaybackSearching Recorded Data Stop ButtonRecord Button RecordingMonitor Displays During Recording Available Multiscreen Displays Entering Active Cameo ModeDisplay Options Active CameosDwell Time Returning To The Default Sequence ListSequencing Selecting CamerasSequencing In Cameos On-screen IndicatorsChanging Position And Color Of Title And Status Indicators Status IndicatorsATM/POS Text Display Triplex ModeConditional Indicators Status Display BoxReverse Play Button Jog / Shuttle Freeze Button Stop Button StopZoom and Function Button Print Image FeatureNumber Button Sequence Button Conditions Printer SetupEquipment Available Menus Accessing The Menu SystemMenu System Overview Menu Notation In This ManualOpening the Drop Down Menus Rotate the Jog Menus In This ManualNavigating The Menu System Menu ShortcutsMain Menu → Time/Date → Time / Date Display Main MenuTime/Date Main Menu OverviewMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Set Date FormatMain Menu → Time/Date → Set Date Main Menu → Time/Date → Set Region Main Menu → Time/Date → Network Time SetupMain Menu → Sequencing → Fullscreen Dwell RecordMain Menu → Sequencing → Multiscreen Dwell Record Quality Picture Quality Disk Space Needed Main Menu → Record → Record TimerMain Menu → Record → Event Settings Main Menu → Record → Record QualityCamera 1 0.40 pps 2.5 spp Main Menu → Record → Timelapse Record RateMain Menu → Record → Activity Record Rate Main Menu → Record → Event Record RateDays 16 h Total Main Menu → Record → Alarm Record RateWrite Once Main Menu → Record → Record ModeMain Menu → Record → Disk Maintenance No OverwriteShould not be the only alarm device on site AlarmsMain Menu → Record → Auto Delete Mode Main Menu → Alarms → Input ConfigurationMain Menu → Alarms → Alarm Action Main Menu → Alarms → Alarm Latch∙ Enable All ∙ Disable All Main Menu → Alarms → Alarm Record ModeMain Menu → Alarms → Enable / Disable Main Menu → Alarms → Alarm HistoryMain Menu → Alarms → Buzzer Setup Main Menu → Alarms → Link To a MacroMain Menu → Alarms → Fullscreen Alarm Main Menu → Alarms → Relay ConfigurationEmail Notification Setup Main Menu → Alarms → Videoloss ActionMain Menu → Alarms → Pre Alarm Duration Main Menu → Alarms → NotificationEnable TCP/IP Notification SetupMain Menu → Macro → Macro Record Main Menu → Alarms → Archive AlarmsMacro Main Menu → Macro → Timed Macro Start Macro Excluded FeaturesDaylight Savings Time Alternate Method Motion DetectionMain Menu → Macro → Edit Submacro Running a MacroActivity Detection Setup Main Menu → Motion Detection → Enable/Disable DetectionIndividual Enable Menu Main Menu → Motion Detection → Setup ParametersActivity Grid Setup Screen Intrusion Detection SetupMain Menu → Motion Detection → Setup Active Zones Main Menu → Motion Detection → Indicate Detection Camera SetupMain Menu → Camera Setup → Camera Titles Sensitivity ScopeCamera Title Edit Menu Main Menu → Camera Setup → AGCTitles Display Edit TitlesAuto Disable Now Main Menu → Camera Setup → Camera DisableIndividual Disable Power Up DisableLuminance Histogram Archive SetupMain Menu → Camera Setup → Camera Scope Main Menu → Archive Setup → Port SelectCommunications Audio SetupPort Pots SetupMain Menu → Communications → RS485 Main Menu → Communications → Ethernet SettingsBaud Rate Front Panel Lock Factory SettingsReturn To Factory Defaults Changing the Installer or Operator PasswordsDeactivate The Ethernet Password QuickInstall MenuEthernet Password Activate The Ethernet PasswordSystemView Menu Overview Operator MenuSystemView Menu Operator Menu OverviewView Screen Alarm ActionCamera ∙ Enable/Disable 1 = Enabled, 0 = Disabled View ScreensRecord Rate Record Timer∙ Relay Output None, 1, 2, 1+2 ∙ Link to Event Yes or No ∙ Target Size 1 through∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off ∙ Network Address∙ Keyboard Lock On or Off ∙ Record Lock On or Off Alarm Acknowledge AlarmsAlarm Input Alarm OutputChannel Units Alarm Operations During PlaybackMonitor-B Display During Alarm Live Alarms DisplaysRecorded Alarms Alarm History BoxSearching For Recorded Alarms Search Menu Overview SearchingSearch Button Disk Analysis ScreenQuick Archive to CD Function Button Motion SearchSelecting Search Parameters Search FiltersActivate Search Search ResultsWebBrowser To access the web interface∙ The Main Viewing Area The large blue area WaveBrowser Overview and ControlsMain Viewing Area Button Panel Drop Down Volume List BoxName Code Description Example DVMRe Triplex WaveLinkFunctionality Email Links Video Technical SpecificationsGeneral ConnectionsPart Numbers AudioMotion Detection Message Type Alarm/Event FieldAlarm/Event Message StructureAlarm/Event Description Front Panel Button EmulationData Structure Data structure Configuration and StatusMacro Description Number Macro TablesMacro Functions Table Event Day Time Macro to Run Scheduled Macro TableFactory Address Warranty and ServiceFactory Service Advance Replacement Policy Warranty and Return Information0150-0193F