| TCP/IP Notification Setup |
|
| ||
One or more of these |
| Notify Vidloss: | DISABLE |
|
| ||||
fields must be set to |
| Notify Alarm: | DISABLE |
|
| ||||
ENABLE to receive an |
|
|
| Notify Record: | DISABLE |
|
| ||
|
|
|
| ||||||
email notification of |
|
|
| ||||||
the selected event. |
| Notify Archive: | DISABLE |
|
| ||||
|
|
|
|
| Notify Menu Access: | DISABLE |
|
| |
|
|
|
|
| Notify Power Up: | DISABLE |
|
| |
|
|
|
|
| Notify Connection: | DISABLE |
|
| |
The IP Addresses |
|
|
|
| Primary Host: | 0. | 0. | 0. | 0 |
|
|
| Backup Host: | 0. | 0. | 0. | 0 | ||
of the PC on which |
|
| |||||||
the WaveReader |
| Port: | 1027 |
|
| ||||
Software resides |
| Notification Interval (minutes): Immediate |
| ||||||
|
|
|
|
|
| ||||
|
|
|
|
| [CANCEL] | [OK] |
|
|
|
The Notification Interval can be set from 1 minute to 60 minutes, or immediately upon the event.
qMain Menu → Alarms → Archive Alarms
Selecting Enable from this menu will cause the unit to activate Relay 2 if a malfunction occurs while archiving.
Archive Alarm
Relay 2
ENABLE
3.12 Macro
A macro is a recorded sequence of keystrokes. The number of macros depends on the number of camera inputs (4, 10 or 16). Each macro can have up to 32 keystrokes.
Use this menu to:
∙Enter Macro Record mode.
∙Program a scheduled start time for a macro.
∙Edit the RS232 command string for each submacro.
Macro Record
Timed Macro Start
Edit Submacro
qMain Menu → Macro → Macro Record
Note: Do not attempt macro programming while the front panel is locked.
To begin recording a macro:
1.Select the macro number you wish to record, then press the Enter button. The unit will automatically exit the menu system and go to a starting point. Macro Record mode
is indicated as F and the Macro Number
Macro Record
Select Macro
01
2.From this point, begin recording the desired keystroke sequence. Record up to 32 keystrokes. If 32 keystrokes are exceeded, the unit will end the macro recording automatically.
3.When finished programming, press the Function button then the Enter button to end the macro recording. A form is provided in section 10 to keep track of recorded macro functions.