2.To save changes and exit the menu: Select [OK], and then press the Enter button.
3.To exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button.
qMain Menu → Record → Event Record Rate
The unit will record at the Event Record Rate when an Event is activated. Events can be activated by RS232 event generation or activity detection. See Event Settings on page 35.
Record rates are measured in both Pictures Per Second (pps) and Seconds Per Picture (spp).
The maximum record rate per camera is inversely proportional to the number of cameras connected to the unit. The fewer cameras connected, the higher the maximum record rate for each camera, and vice versa. The maximum record rate for multiple cameras is 48pps (NTSC)(40pps PAL). The maximum record rate for a single camera is 30pps (NTSC)(25pps PAL).
The bottom right corner of the menu contains a record duration calculator. The top line indicates the estimated recording time of the cameras in Event record mode only. The bottom line indicates the estimated recording time, taking into consideration the amount of time the unit will spend in
|
| Event Record Rate |
|
|
|
| |
Camera | 1 : 0.40 pps 2.5 spp | % Time: 4% |
|
| Estimate of the % of time each | ||
|
| ||||||
Camera | 2 | : 0.29 pps 3.5 spp |
|
|
| camera will typically spend in | |
|
|
| Event mode. For example if you | ||||
Camera | 3 | : 0.34 pps 2.9 spp |
|
|
| ||
|
|
| expect to have about 20 total | ||||
Camera | 4 | : 0.57 pps 1.8 spp |
|
|
| events each day, each lasting 3 | |
|
|
| minutes on average, then the % | ||||
|
| : |
|
|
|
| |
|
|
|
|
|
| of the time will be 4%. | |
|
| : |
|
|
|
| (1 hour/24 hours) |
|
|
|
|
|
|
| |
|
| : |
|
|
|
|
|
Camera 15 | : 0.40 pps 2.5 spp |
|
|
|
| ||
Camera 16 | : 0.40 pps 2.5 spp |
|
|
|
| ||
|
|
| 125 days 8 h (EVENT) |
|
| ||
| [CANCEL] [OK] | 10 days 7 h (Total) |
|
|
1.Rotate the Jog to navigate, and the Shuttle to change the values.
2.To save changes and exit the menu: Select [OK], and then press the Enter button.
3.To exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button.
qMain Menu → Record → Activity Record Rate
The unit will record at the Activity Record Rate when the camera is in normal Timelapse Record Mode and activity is detected in the camera scene. Activity should not be linked to Event, in which case the Event Record Rate will be used.
Record rates are measured in both Pictures Per Second (pps) and Seconds Per Picture (spp).
38 | Kalatel DVMRe Triplex |