GE DVMRe user manual Intrusion Detection Setup, Main Menu → Motion Detection → Setup Active Zones

Page 51

Relay Output: The unit may be configured to activate a relay output when motion detection is present. Select either 1, 2, 1+2 (both relays), or None.

Link to Event: Selecting Yes in this menu will activate the event record speed when activity detection is present.

Intrusion Detection Setup

If Intrusion is selected in Motion Detection Type field, the following parameters are enabled:

Sensitivity: Rotate the Shuttle to change the motion detection sensitivity, 10 being the most sensitive.

Rejection: Configure the unit’s false alarm rejection feature by selecting Low, Medium, or High. These settings are based on the number of simultaneously triggered zones and the persistence of motion in a scene. The Low setting is the most sensitive to motion. The Medium setting will filter out most false alarm situations due to sudden luminance changes over the whole scene (clouds passing over). The High setting will filter out sudden luminance changes as well as spurious motion events that do not persist for a number of frames (a bird flying past the lens).

Target Size: This setting is the minimum number of zones (from the 16 x 16 grid) that must be activated simultaneously before it is considered to be valid motion.

Link To Alarm: Select the alarm number that you wish to activate when motion detection is activated.

qMain Menu Motion Detection Setup Active Zones

Use this menu to setup the Active Zones for motion detection. The screen shown below will overlay the current video image allowing for precise activity zone setup. The disabled zones will be tinted. The enabled zones will be clear.

Activity Grid Setup Screen

5

0150-0193F

51

Kalatel DVMRe Triplex

Image 51
Contents Kalatel DVMRe Triplex Page Important Information Contents WebBrowser AlarmsRS232 Remote Control Protocol Searching11.2 11Warranty and Service10.2 Scheduled Macro Table 11.1Product Description Products Featured In This ManualFeatures DVMRe Triplex OverviewDefault Passwords Four-Channel Units PasswordsTen and Sixteen-Channel Units Installation EnvironmentPackage Contents UnpackingBack Panel Associated EquipmentMonitor Output Alarm I/O PortCamera Inputs Composite Monitor OutputAlarm Input Alarm PCBNormally Open and Normally Closed Connections Voltage 30V Max Alarm Relay OutputExternal Alarm Acknowledge Input AUX PortRS485 Connector RJ-45 Pin Configuration For RS485 PortEthernet Port Gender on unit Female RJ-45 Pin Configuration For Ethernet PortIeee 1394 Firewire Port Scsi PortPower-Up Minimum Recommended Menu Setup QuickInstall Main Menu Location Section Menu Item ManualCheck Record And Playback Quality Play Forward Button Begins Playback DMVRe Triplex Basic OperationsPrincipal Operating Modes Front PanelLive Viewing Playback Sequence Button Number Button Stop PlaybackSearching Recorded Data Stop ButtonRecording Monitor Displays During RecordingRecord Button Available Multiscreen Displays Entering Active Cameo ModeDisplay Options Active CameosDwell Time Returning To The Default Sequence ListSequencing Selecting CamerasSequencing In Cameos On-screen IndicatorsChanging Position And Color Of Title And Status Indicators Status IndicatorsATM/POS Text Display Triplex ModeConditional Indicators Status Display BoxReverse Play Button Jog / Shuttle Freeze Button Stop Button StopPrint Image Feature Number Button Sequence ButtonZoom and Function Button Printer Setup EquipmentConditions Available Menus Accessing The Menu SystemMenu System Overview Menu Notation In This ManualOpening the Drop Down Menus Rotate the Jog Menus In This ManualNavigating The Menu System Menu ShortcutsMain Menu → Time/Date → Time / Date Display Main MenuTime/Date Main Menu OverviewMain Menu → Time/Date → Set Date Format Main Menu → Time/Date → Set DateMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Set Region Main Menu → Time/Date → Network Time SetupRecord Main Menu → Sequencing → Multiscreen DwellMain Menu → Sequencing → Fullscreen Dwell Record Quality Picture Quality Disk Space Needed Main Menu → Record → Record TimerMain Menu → Record → Event Settings Main Menu → Record → Record QualityCamera 1 0.40 pps 2.5 spp Main Menu → Record → Timelapse Record RateMain Menu → Record → Activity Record Rate Main Menu → Record → Event Record RateDays 16 h Total Main Menu → Record → Alarm Record RateWrite Once Main Menu → Record → Record ModeMain Menu → Record → Disk Maintenance No OverwriteShould not be the only alarm device on site AlarmsMain Menu → Record → Auto Delete Mode Main Menu → Alarms → Input ConfigurationMain Menu → Alarms → Alarm Action Main Menu → Alarms → Alarm Latch∙ Enable All ∙ Disable All Main Menu → Alarms → Alarm Record ModeMain Menu → Alarms → Enable / Disable Main Menu → Alarms → Alarm HistoryMain Menu → Alarms → Buzzer Setup Main Menu → Alarms → Link To a MacroMain Menu → Alarms → Fullscreen Alarm Main Menu → Alarms → Relay ConfigurationEmail Notification Setup Main Menu → Alarms → Videoloss ActionMain Menu → Alarms → Pre Alarm Duration Main Menu → Alarms → NotificationEnable TCP/IP Notification SetupMain Menu → Alarms → Archive Alarms MacroMain Menu → Macro → Macro Record Main Menu → Macro → Timed Macro Start Macro Excluded FeaturesDaylight Savings Time Alternate Method Motion DetectionMain Menu → Macro → Edit Submacro Running a MacroActivity Detection Setup Main Menu → Motion Detection → Enable/Disable DetectionIndividual Enable Menu Main Menu → Motion Detection → Setup ParametersIntrusion Detection Setup Main Menu → Motion Detection → Setup Active ZonesActivity Grid Setup Screen Main Menu → Motion Detection → Indicate Detection Camera SetupMain Menu → Camera Setup → Camera Titles Sensitivity ScopeCamera Title Edit Menu Main Menu → Camera Setup → AGCTitles Display Edit TitlesAuto Disable Now Main Menu → Camera Setup → Camera DisableIndividual Disable Power Up DisableLuminance Histogram Archive SetupMain Menu → Camera Setup → Camera Scope Main Menu → Archive Setup → Port SelectCommunications Audio SetupPort Pots SetupMain Menu → Communications → Ethernet Settings Baud RateMain Menu → Communications → RS485 Front Panel Lock Factory SettingsReturn To Factory Defaults Changing the Installer or Operator PasswordsDeactivate The Ethernet Password QuickInstall MenuEthernet Password Activate The Ethernet PasswordSystemView Menu Overview Operator MenuSystemView Menu Operator Menu OverviewView Screen Alarm ActionCamera ∙ Enable/Disable 1 = Enabled, 0 = Disabled View ScreensRecord Rate Record Timer∙ Relay Output None, 1, 2, 1+2 ∙ Link to Event Yes or No ∙ Target Size 1 through∙ Network Address ∙ Keyboard Lock On or Off ∙ Record Lock On or Off∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off Alarm Acknowledge AlarmsAlarm Input Alarm OutputChannel Units Alarm Operations During PlaybackMonitor-B Display During Alarm Live Alarms DisplaysAlarm History Box Searching For Recorded AlarmsRecorded Alarms Search Menu Overview SearchingDisk Analysis Screen Quick Archive to CDSearch Button Function Button Motion SearchSelecting Search Parameters Search FiltersActivate Search Search ResultsWebBrowser To access the web interfaceWaveBrowser Overview and Controls Main Viewing Area∙ The Main Viewing Area The large blue area Button Panel Drop Down Volume List BoxDVMRe Triplex WaveLink FunctionalityName Code Description Example Email Links Video Technical SpecificationsGeneral ConnectionsAudio Motion DetectionPart Numbers Message Type Alarm/Event FieldAlarm/Event Message StructureAlarm/Event Front Panel Button Emulation Data StructureDescription Data structure Configuration and StatusMacro Tables Macro Functions TableMacro Description Number Event Day Time Macro to Run Scheduled Macro TableWarranty and Service Factory ServiceFactory Address Advance Replacement Policy Warranty and Return Information0150-0193F