Port 1

Use this menu to:

Enable/Disable POTS and configure the Modem initialization string (POTS Setup).

Adjust the Baud rate.

POTS Setup

Baud Rate

POTS Setup

The default modem string (shown below) is for use with Hayes Accura 56k, Diamond Supra Express 56k, and 5686 US Robotics modems in their default conditions. Consult with the modem manual before attempting to make any changes. It is strongly recommended that the modem initialization string only be modified by a qualified technician.

POTS Setup

POTS : DISABLE

Modem Init String : AT&F1&K3M0E1Q0V1S0=0&R2&C1&D0&H1

[Default Modem String] [CANCEL] [OK]

@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]^

SEQ key selects character bank ‘1’ key inserts blank character ‘2’ key inserts selected character

1.With the Modem Init String highlighted, press the Enter button to enter the Edit mode. The character bank will appear in the center of the menu.

2.Press the Sequence button to select the desired character bank.

3.Rotate the Shuttle to navigate the Modem Init String.

4.Rotate the Jog to select a character from the character bank.

5.Use the Number 2 button or rotate the Shuttle to insert the desired character from the character bank into the Modem Init String and advance to the next character.

6.Use the Number 1 button to insert a blank character.

7.When finished, press the Enter button.

8.To save the changes and reboot, select OK, then press the Enter button. The unit will only reboot if changes were made to the Modem Init String.

9.To exit the menu without making changes, select Cancel, then press the Enter button. Pressing the Menu button also exits the menu without making changes.

0150-0193F

57

Kalatel DVMRe Triplex

Image 57
Contents Kalatel DVMRe Triplex Page Important Information Contents RS232 Remote Control Protocol AlarmsSearching WebBrowser10.2 Scheduled Macro Table 11Warranty and Service11.1 11.2Features Products Featured In This ManualDVMRe Triplex Overview Product DescriptionDefault Passwords Four-Channel Units PasswordsPackage Contents Installation EnvironmentUnpacking Ten and Sixteen-Channel UnitsBack Panel Associated EquipmentCamera Inputs Alarm I/O PortComposite Monitor Output Monitor OutputAlarm Input Alarm PCBNormally Open and Normally Closed Connections External Alarm Acknowledge Input Alarm Relay OutputAUX Port Voltage 30V MaxRS485 Connector RJ-45 Pin Configuration For RS485 PortEthernet Port Ieee 1394 Firewire Port RJ-45 Pin Configuration For Ethernet PortScsi Port Gender on unit FemalePower-Up Minimum Recommended Menu Setup QuickInstall Main Menu Location Section Menu Item ManualCheck Record And Playback Quality Principal Operating Modes DMVRe Triplex Basic OperationsFront Panel Play Forward Button Begins PlaybackLive Viewing Playback Searching Recorded Data Stop PlaybackStop Button Sequence Button Number ButtonRecording Monitor Displays During RecordingRecord Button Display Options Entering Active Cameo ModeActive Cameos Available Multiscreen DisplaysSequencing Returning To The Default Sequence ListSelecting Cameras Dwell TimeChanging Position And Color Of Title And Status Indicators On-screen IndicatorsStatus Indicators Sequencing In CameosConditional Indicators Triplex ModeStatus Display Box ATM/POS Text DisplayReverse Play Button Jog / Shuttle Freeze Button Stop Button StopPrint Image Feature Number Button Sequence ButtonZoom and Function Button Printer Setup EquipmentConditions Menu System Overview Accessing The Menu SystemMenu Notation In This Manual Available MenusNavigating The Menu System Menus In This ManualMenu Shortcuts Opening the Drop Down Menus Rotate the JogTime/Date Main MenuMain Menu Overview Main Menu → Time/Date → Time / Date DisplayMain Menu → Time/Date → Set Date Format Main Menu → Time/Date → Set DateMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Set Region Main Menu → Time/Date → Network Time SetupRecord Main Menu → Sequencing → Multiscreen DwellMain Menu → Sequencing → Fullscreen Dwell Main Menu → Record → Event Settings Main Menu → Record → Record TimerMain Menu → Record → Record Quality Record Quality Picture Quality Disk Space NeededCamera 1 0.40 pps 2.5 spp Main Menu → Record → Timelapse Record RateMain Menu → Record → Activity Record Rate Main Menu → Record → Event Record RateDays 16 h Total Main Menu → Record → Alarm Record RateMain Menu → Record → Disk Maintenance Main Menu → Record → Record ModeNo Overwrite Write OnceMain Menu → Record → Auto Delete Mode AlarmsMain Menu → Alarms → Input Configuration Should not be the only alarm device on siteMain Menu → Alarms → Alarm Action Main Menu → Alarms → Alarm LatchMain Menu → Alarms → Enable / Disable Main Menu → Alarms → Alarm Record ModeMain Menu → Alarms → Alarm History ∙ Enable All ∙ Disable AllMain Menu → Alarms → Fullscreen Alarm Main Menu → Alarms → Link To a MacroMain Menu → Alarms → Relay Configuration Main Menu → Alarms → Buzzer SetupMain Menu → Alarms → Pre Alarm Duration Main Menu → Alarms → Videoloss ActionMain Menu → Alarms → Notification Email Notification SetupEnable TCP/IP Notification SetupMain Menu → Alarms → Archive Alarms MacroMain Menu → Macro → Macro Record Main Menu → Macro → Timed Macro Start Macro Excluded FeaturesMain Menu → Macro → Edit Submacro Motion DetectionRunning a Macro Daylight Savings Time Alternate MethodIndividual Enable Menu Main Menu → Motion Detection → Enable/Disable DetectionMain Menu → Motion Detection → Setup Parameters Activity Detection SetupIntrusion Detection Setup Main Menu → Motion Detection → Setup Active ZonesActivity Grid Setup Screen Main Menu → Camera Setup → Camera Titles Camera SetupSensitivity Scope Main Menu → Motion Detection → Indicate DetectionTitles Display Main Menu → Camera Setup → AGCEdit Titles Camera Title Edit MenuIndividual Disable Main Menu → Camera Setup → Camera DisablePower Up Disable Auto Disable NowMain Menu → Camera Setup → Camera Scope Archive SetupMain Menu → Archive Setup → Port Select Luminance HistogramCommunications Audio SetupPort Pots SetupMain Menu → Communications → Ethernet Settings Baud RateMain Menu → Communications → RS485 Return To Factory Defaults Factory SettingsChanging the Installer or Operator Passwords Front Panel LockEthernet Password QuickInstall MenuActivate The Ethernet Password Deactivate The Ethernet PasswordSystemView Menu Operator MenuOperator Menu Overview SystemView Menu OverviewCamera ∙ Enable/Disable 1 = Enabled, 0 = Disabled Alarm ActionView Screens View Screen∙ Relay Output None, 1, 2, 1+2 ∙ Link to Event Yes or No Record Timer∙ Target Size 1 through Record Rate∙ Network Address ∙ Keyboard Lock On or Off ∙ Record Lock On or Off∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off Alarm Input AlarmsAlarm Output Alarm AcknowledgeMonitor-B Display During Alarm Alarm Operations During PlaybackLive Alarms Displays Channel UnitsAlarm History Box Searching For Recorded AlarmsRecorded Alarms Search Menu Overview SearchingDisk Analysis Screen Quick Archive to CDSearch Button Function Button Motion SearchSelecting Search Parameters Search FiltersActivate Search Search ResultsWebBrowser To access the web interfaceWaveBrowser Overview and Controls Main Viewing Area∙ The Main Viewing Area The large blue area Button Panel Drop Down Volume List BoxDVMRe Triplex WaveLink FunctionalityName Code Description Example Email Links General Technical SpecificationsConnections VideoAudio Motion DetectionPart Numbers Alarm/Event Alarm/Event FieldMessage Structure Message TypeAlarm/Event Front Panel Button Emulation Data StructureDescription Data structure Configuration and StatusMacro Tables Macro Functions TableMacro Description Number Event Day Time Macro to Run Scheduled Macro TableWarranty and Service Factory ServiceFactory Address Advance Replacement Policy Warranty and Return Information0150-0193F