GE DVMRe user manual Minimum Recommended Menu Setup, Check Record And Playback Quality

Page 17

Check Record And Playback Quality

Record for at least three minutes at the default record rate. Then play back the recording, selecting each camera for full screen display. Check the playback picture quality.

1.9 Minimum Recommended Menu Setup

After installation is complete, it is strongly recommended that, as a minimum, the items in the QuickInstall menu be configured before the unit is used. All the features located in the QuickInstall menu are also found in the Main menu. These items are provided in the separate QuickInstall menu as a convenience for the installer.

For information about accessing and configuring the menu system, see Section 3.

To find detailed information in this manual about configuring each item in the QuickInstall menu, use the following table to locate the main menu location of each item in the QuickInstall menu.

QuickInstall

Main Menu Location

Section in

Menu Item

 

Manual

 

 

 

Change the time

Main Menu Time/Date Set Time

3.8

 

 

 

Change the date

Main Menu Time/Date Set Date

3.8

 

 

 

Edit Camera

Main Menu Camera Setup Camera Titles Edit Titles

3.14

Titles

 

 

 

 

 

Camera Disable

Main Menu Camera Setup Camera Disable

3.14

 

 

 

Record Quality

Main Menu Record Record Quality

3.10

 

 

 

Installer

Main Menu Passwords Installer Password

3.20

Password

 

 

 

 

 

Auto Disable

Main Menu Camera Setup Camera Disable Auto

3.14

Now

Disable Now

 

 

 

 

0150-0193F

17

Kalatel DVMRe Triplex

Image 17
Contents Kalatel DVMRe Triplex Page Important Information Contents RS232 Remote Control Protocol AlarmsSearching WebBrowser10.2 Scheduled Macro Table 11Warranty and Service11.1 11.2Features Products Featured In This ManualDVMRe Triplex Overview Product DescriptionDefault Passwords Four-Channel Units PasswordsPackage Contents Installation EnvironmentUnpacking Ten and Sixteen-Channel UnitsBack Panel Associated EquipmentCamera Inputs Alarm I/O PortComposite Monitor Output Monitor OutputNormally Open and Normally Closed Connections Alarm InputAlarm PCB External Alarm Acknowledge Input Alarm Relay OutputAUX Port Voltage 30V MaxEthernet Port RS485 ConnectorRJ-45 Pin Configuration For RS485 Port Ieee 1394 Firewire Port RJ-45 Pin Configuration For Ethernet PortScsi Port Gender on unit FemalePower-Up Check Record And Playback Quality Minimum Recommended Menu SetupQuickInstall Main Menu Location Section Menu Item Manual Principal Operating Modes DMVRe Triplex Basic OperationsFront Panel Play Forward Button Begins PlaybackLive Viewing Playback Searching Recorded Data Stop PlaybackStop Button Sequence Button Number ButtonRecord Button RecordingMonitor Displays During Recording Display Options Entering Active Cameo ModeActive Cameos Available Multiscreen DisplaysSequencing Returning To The Default Sequence ListSelecting Cameras Dwell TimeChanging Position And Color Of Title And Status Indicators On-screen IndicatorsStatus Indicators Sequencing In CameosConditional Indicators Triplex ModeStatus Display Box ATM/POS Text DisplayReverse Play Button Jog / Shuttle Freeze Button Stop Button StopZoom and Function Button Print Image FeatureNumber Button Sequence Button Conditions Printer SetupEquipment Menu System Overview Accessing The Menu SystemMenu Notation In This Manual Available MenusNavigating The Menu System Menus In This ManualMenu Shortcuts Opening the Drop Down Menus Rotate the JogTime/Date Main MenuMain Menu Overview Main Menu → Time/Date → Time / Date DisplayMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Set Date FormatMain Menu → Time/Date → Set Date Main Menu → Time/Date → Set Region Main Menu → Time/Date → Network Time SetupMain Menu → Sequencing → Fullscreen Dwell RecordMain Menu → Sequencing → Multiscreen Dwell Main Menu → Record → Event Settings Main Menu → Record → Record TimerMain Menu → Record → Record Quality Record Quality Picture Quality Disk Space NeededCamera 1 0.40 pps 2.5 spp Main Menu → Record → Timelapse Record RateMain Menu → Record → Activity Record Rate Main Menu → Record → Event Record RateDays 16 h Total Main Menu → Record → Alarm Record RateMain Menu → Record → Disk Maintenance Main Menu → Record → Record ModeNo Overwrite Write OnceMain Menu → Record → Auto Delete Mode AlarmsMain Menu → Alarms → Input Configuration Should not be the only alarm device on siteMain Menu → Alarms → Alarm Action Main Menu → Alarms → Alarm LatchMain Menu → Alarms → Enable / Disable Main Menu → Alarms → Alarm Record ModeMain Menu → Alarms → Alarm History ∙ Enable All ∙ Disable AllMain Menu → Alarms → Fullscreen Alarm Main Menu → Alarms → Link To a MacroMain Menu → Alarms → Relay Configuration Main Menu → Alarms → Buzzer SetupMain Menu → Alarms → Pre Alarm Duration Main Menu → Alarms → Videoloss ActionMain Menu → Alarms → Notification Email Notification SetupEnable TCP/IP Notification SetupMain Menu → Macro → Macro Record Main Menu → Alarms → Archive AlarmsMacro Main Menu → Macro → Timed Macro Start Macro Excluded FeaturesMain Menu → Macro → Edit Submacro Motion DetectionRunning a Macro Daylight Savings Time Alternate MethodIndividual Enable Menu Main Menu → Motion Detection → Enable/Disable DetectionMain Menu → Motion Detection → Setup Parameters Activity Detection SetupActivity Grid Setup Screen Intrusion Detection SetupMain Menu → Motion Detection → Setup Active Zones Main Menu → Camera Setup → Camera Titles Camera SetupSensitivity Scope Main Menu → Motion Detection → Indicate DetectionTitles Display Main Menu → Camera Setup → AGCEdit Titles Camera Title Edit MenuIndividual Disable Main Menu → Camera Setup → Camera DisablePower Up Disable Auto Disable NowMain Menu → Camera Setup → Camera Scope Archive SetupMain Menu → Archive Setup → Port Select Luminance HistogramCommunications Audio SetupPort Pots SetupMain Menu → Communications → RS485 Main Menu → Communications → Ethernet SettingsBaud Rate Return To Factory Defaults Factory SettingsChanging the Installer or Operator Passwords Front Panel LockEthernet Password QuickInstall MenuActivate The Ethernet Password Deactivate The Ethernet PasswordSystemView Menu Operator MenuOperator Menu Overview SystemView Menu OverviewCamera ∙ Enable/Disable 1 = Enabled, 0 = Disabled Alarm ActionView Screens View Screen∙ Relay Output None, 1, 2, 1+2 ∙ Link to Event Yes or No Record Timer∙ Target Size 1 through Record Rate∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off ∙ Network Address∙ Keyboard Lock On or Off ∙ Record Lock On or Off Alarm Input AlarmsAlarm Output Alarm AcknowledgeMonitor-B Display During Alarm Alarm Operations During PlaybackLive Alarms Displays Channel UnitsRecorded Alarms Alarm History BoxSearching For Recorded Alarms Search Menu Overview SearchingSearch Button Disk Analysis ScreenQuick Archive to CD Function Button Motion SearchSelecting Search Parameters Search FiltersActivate Search Search ResultsWebBrowser To access the web interface∙ The Main Viewing Area The large blue area WaveBrowser Overview and ControlsMain Viewing Area Button Panel Drop Down Volume List BoxName Code Description Example DVMRe Triplex WaveLinkFunctionality Email Links General Technical SpecificationsConnections VideoPart Numbers AudioMotion Detection Alarm/Event Alarm/Event FieldMessage Structure Message TypeAlarm/Event Description Front Panel Button EmulationData Structure Data structure Configuration and StatusMacro Description Number Macro TablesMacro Functions Table Event Day Time Macro to Run Scheduled Macro TableFactory Address Warranty and ServiceFactory Service Advance Replacement Policy Warranty and Return Information0150-0193F