Page 28

Multiscreen Display With Sequencing

The bottom right cameo of any multiscreen will start sequencing when the Sequence button is pressed. If this camera is a playback image, the sequencing will include all the non-displayed playback cameras, and vice versa for a live image.

Sequence Button

Full Screen Display

Select any camera for Full Screen display by pressing the Number button of the desired camera. Pressing the Camera number button again displays the Status Display Box. Pressing the same button a third time displays any associated ATM or cash register ASCII text.

Sequenced Full Screen Display

While in a Full Screen display, press the Sequence button to begin full screen sequencing. The sequence list and dwell times are programmable. For detailed information about programming the sequence list see section

2.8.For detailed information about configuring the dwell times in the menu system, see section 0.

1

Number Button

Sequence Button

Zooming

To activate the 2x digital zoom, select the full screen display of the camera you wish to zoom, then press the Zoom button. Zooming will be indicated by the LED located directly above the Zoom button. Zooming is also indicated as ZOOM on the monitor. Zooming works with frozen and non-frozen images. Zoomed images can also be frozen.

While Zoomed, use the Jog/Shuttle to Pan and Tilt across the image. Please note, the camera does not move during digital Pan/Tilt.

Press the Zoom button again, or another camera button to cancel the Zoom operations.

Zoom Button

with LED

NOTE

If the Zoom button is pressed while in a multiscreen display, the camera from the last active

cameo is selected for full screen display. Press the Zoom button again to activate the Zoom

 

 

 

operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

2.11 The Print Image Feature

Pressing the Function and Zoom button will print the currently displayed image. If any multiscreen is the display mode, the Triplex will switch to a single image display of the last selected fullscreen camera, freeze the image, and send to the default printer.

{F}

Zoom and Function

Button

0150-0193F

28

Kalatel DVMRe Triplex

Image 28
Contents Kalatel DVMRe Triplex Page Important Information Contents Alarms RS232 Remote Control ProtocolSearching WebBrowser11Warranty and Service 10.2 Scheduled Macro Table11.1 11.2Products Featured In This Manual FeaturesDVMRe Triplex Overview Product DescriptionPasswords Default Passwords Four-Channel UnitsInstallation Environment Package ContentsUnpacking Ten and Sixteen-Channel UnitsAssociated Equipment Back PanelAlarm I/O Port Camera InputsComposite Monitor Output Monitor OutputAlarm PCB Alarm InputNormally Open and Normally Closed Connections Alarm Relay Output External Alarm Acknowledge InputAUX Port Voltage 30V MaxRJ-45 Pin Configuration For RS485 Port RS485 ConnectorEthernet Port RJ-45 Pin Configuration For Ethernet Port Ieee 1394 Firewire PortScsi Port Gender on unit FemalePower-Up QuickInstall Main Menu Location Section Menu Item Manual Minimum Recommended Menu SetupCheck Record And Playback Quality DMVRe Triplex Basic Operations Principal Operating ModesFront Panel Play Forward Button Begins PlaybackLive Viewing Playback Stop Playback Searching Recorded DataStop Button Sequence Button Number ButtonMonitor Displays During Recording RecordingRecord Button Entering Active Cameo Mode Display OptionsActive Cameos Available Multiscreen DisplaysReturning To The Default Sequence List SequencingSelecting Cameras Dwell Time On-screen Indicators Changing Position And Color Of Title And Status Indicators Status Indicators Sequencing In CameosTriplex Mode Conditional IndicatorsStatus Display Box ATM/POS Text DisplayStop Reverse Play Button Jog / Shuttle Freeze Button Stop ButtonNumber Button Sequence Button Print Image FeatureZoom and Function Button Equipment Printer SetupConditions Accessing The Menu System Menu System OverviewMenu Notation In This Manual Available MenusMenus In This Manual Navigating The Menu SystemMenu Shortcuts Opening the Drop Down Menus Rotate the JogMain Menu Time/DateMain Menu Overview Main Menu → Time/Date → Time / Date DisplayMain Menu → Time/Date → Set Date Main Menu → Time/Date → Set Date FormatMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Network Time Setup Main Menu → Time/Date → Set RegionMain Menu → Sequencing → Multiscreen Dwell RecordMain Menu → Sequencing → Fullscreen Dwell Main Menu → Record → Record Timer Main Menu → Record → Event SettingsMain Menu → Record → Record Quality Record Quality Picture Quality Disk Space NeededMain Menu → Record → Timelapse Record Rate Camera 1 0.40 pps 2.5 sppMain Menu → Record → Event Record Rate Main Menu → Record → Activity Record RateMain Menu → Record → Alarm Record Rate Days 16 h TotalMain Menu → Record → Record Mode Main Menu → Record → Disk MaintenanceNo Overwrite Write OnceAlarms Main Menu → Record → Auto Delete ModeMain Menu → Alarms → Input Configuration Should not be the only alarm device on siteMain Menu → Alarms → Alarm Latch Main Menu → Alarms → Alarm ActionMain Menu → Alarms → Alarm Record Mode Main Menu → Alarms → Enable / DisableMain Menu → Alarms → Alarm History ∙ Enable All ∙ Disable AllMain Menu → Alarms → Link To a Macro Main Menu → Alarms → Fullscreen AlarmMain Menu → Alarms → Relay Configuration Main Menu → Alarms → Buzzer SetupMain Menu → Alarms → Videoloss Action Main Menu → Alarms → Pre Alarm DurationMain Menu → Alarms → Notification Email Notification SetupTCP/IP Notification Setup EnableMacro Main Menu → Alarms → Archive AlarmsMain Menu → Macro → Macro Record Macro Excluded Features Main Menu → Macro → Timed Macro StartMotion Detection Main Menu → Macro → Edit SubmacroRunning a Macro Daylight Savings Time Alternate MethodMain Menu → Motion Detection → Enable/Disable Detection Individual Enable MenuMain Menu → Motion Detection → Setup Parameters Activity Detection SetupMain Menu → Motion Detection → Setup Active Zones Intrusion Detection SetupActivity Grid Setup Screen Camera Setup Main Menu → Camera Setup → Camera TitlesSensitivity Scope Main Menu → Motion Detection → Indicate DetectionMain Menu → Camera Setup → AGC Titles DisplayEdit Titles Camera Title Edit MenuMain Menu → Camera Setup → Camera Disable Individual DisablePower Up Disable Auto Disable NowArchive Setup Main Menu → Camera Setup → Camera ScopeMain Menu → Archive Setup → Port Select Luminance HistogramAudio Setup CommunicationsPots Setup PortBaud Rate Main Menu → Communications → Ethernet SettingsMain Menu → Communications → RS485 Factory Settings Return To Factory DefaultsChanging the Installer or Operator Passwords Front Panel LockQuickInstall Menu Ethernet PasswordActivate The Ethernet Password Deactivate The Ethernet PasswordOperator Menu SystemView MenuOperator Menu Overview SystemView Menu OverviewAlarm Action Camera ∙ Enable/Disable 1 = Enabled, 0 = DisabledView Screens View ScreenRecord Timer ∙ Relay Output None, 1, 2, 1+2 ∙ Link to Event Yes or No∙ Target Size 1 through Record Rate∙ Keyboard Lock On or Off ∙ Record Lock On or Off ∙ Network Address∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off Alarms Alarm InputAlarm Output Alarm AcknowledgeAlarm Operations During Playback Monitor-B Display During AlarmLive Alarms Displays Channel UnitsSearching For Recorded Alarms Alarm History BoxRecorded Alarms Searching Search Menu OverviewQuick Archive to CD Disk Analysis ScreenSearch Button Motion Search Function ButtonSearch Filters Selecting Search ParametersSearch Results Activate SearchTo access the web interface WebBrowserMain Viewing Area WaveBrowser Overview and Controls∙ The Main Viewing Area The large blue area Drop Down Volume List Box Button PanelFunctionality DVMRe Triplex WaveLinkName Code Description Example Email Links Technical Specifications GeneralConnections VideoMotion Detection AudioPart Numbers Alarm/Event Field Alarm/EventMessage Structure Message TypeAlarm/Event Data Structure Front Panel Button EmulationDescription Configuration and Status Data structureMacro Functions Table Macro TablesMacro Description Number Scheduled Macro Table Event Day Time Macro to RunFactory Service Warranty and ServiceFactory Address Warranty and Return Information Advance Replacement Policy0150-0193F