Barco RCP-120 manual RCP120 Installation

Page 15

RCP120 Installation

The figure below illustrates a simplified diagram of the FSN Controller and RCP120 connections and the required cabling. Use this figure for reference during installation.

Figure 21: Installation Diagram (sample)

Use the following steps to install the Remote Control Panel:

1.Follow all installation steps outlined in Chapter 4 of the FSN User’s Guide as necessary.

2.Find a suitable flat and stable surface to place the RCP120 on or a free space in the equipment rack in which to mount the RCP120 . Rack screws are supplied with the RCP120 for use with equipment ra ck mounting.

3.Using a standard Ethernet cable, connect the LAN connector on the rear panel of the RCP120 to the customer supplied Ethernet Sw itch that the FSN System is using. This Ethernet Switch must have the connections from the FSN1400 and Ethernet Port 1 of the FSN Controller

4.Connect the 2pin male Phoenix connector on the 12V DC power supply to the female DC Power connector on the rear panel of the RCP120.

5.Ensure the correct power blade is installed on the AC/DC power supply before plugging the supply into an AC outlet.

Remote Control Panel User’s Guide ● Rev 00

15

Image 15
Contents RCP120 Remote Control Panel User’s Guide Copyright Remote Control Panel User’s Guide RevTrademarks Company AddressGrounding the Product Power SourceUse the Proper Power Cord Do Not Remove Covers or PanelsTerms In This Manual and Equipment Marking Description Approved By 09/11 586290 Initial Release Rev DateTable of Contents Universal Power Supply This page intentionally left blank Overview IntroductionApplication Questions Connectivity DiagramRemote Control Panel Orientation RCP120 Front PanelRCP120 Rear Panel 2in Phoenix DC Power Input 4in Phoenix RS32 / IRLAN Installation Unpacking and InspectionWhat’s Included in the Box RCP120 Installation RCP120 Configuration Soft Reboot / Web Interface Password ResetConnecting to the RCP120 Web Interface Remote Control Panel User’s Guide Rev RCP120 Configuration RCP120 Configuration Web Interface Network ConfigurationStatus Master Controller IP Address Change Admin PasswordSerial Port 1 Configuration / Baud Rate Serial Port 2 Configuration / Baud RateSerial Port 1 Auto Transmit Delay Between Default Setting is 30 0.3 Seconds. Used to Button SettingsUpdate and Reboot / Reset Defaults Seconds Before Default Setting is 0 No Timeout. Used toRCP120 Boot Menu Connecting to the Boot MenuOverview RCP120 Boot Menu Interface Selections Not Supported Restore Default SettingsDiscard Changes and Reboot Save Changes and RebootAssign Remote Panels RCP120 FSN Menu OrientationFigure below illustrates the Remote Control Panel Table Remote Control Panel TableAssign Remote Panels Menu Functions Discover Remote Panels Assign Aux UnassignInfo Duplicate IP Address Notification Operations No Connection BehaviorDisplay IP/MAC Address and Firmware Version Understanding Button Mapping AUX Output ControlButton Color Table Understanding Button ColorWorking with the RCP120 Remote Control Panel User’s Guide Rev Setting up the RCP120 to Control an Aux Output FSN System and Controller SetupRCP20 Setup Working with an Unconnected RCP20 Maintenance OperationsAdding Additional RCP20 Devices Unassign an Aux Output from an RCP20Controlling a Standard Aux Output Controlling an Aux Output with the RCP120Program Preview Controlling an Aux Output defined as a MixerSoftware Update Overview Updating SoftwareHardware Requirements Downloading Software Via FTP SiteRCP20revision #.zip Via Web Site RCP20 Firmware Upload Updating RCP120 SoftwareRemote Control Panel User’s Guide Rev Physical and Electrical Specifications SpecificationsConnector Specifications Communications SpecificationsAgency Specifications Power ConnectorSerial Port Figure below illustrates the 4pin Phoenix powe r connectorInstalling a Power Blade Adapter Universal Power SupplyRemote Control Panel User’s Guide Rev Warranty Return Material Authorization RMAContact Information Barco N.V Contact InformationBarco, Inc Sales Contact Information