AMX Mio Modero R-4 manual Sendcommand DEV,LDA-list, Address,uniflag,primary data,data2…

Page 88

Programming the Mio R-4

List Box Commands (Cont.)

Data List Commands

^LDA

Syntax:

Adds a new row to an existing

SEND_COMMAND <DEV>,"'^LDA-<list

data list. Primary data is

address>,<uniflag>,<primary data>,<data2>…'"

required.

Variables:

 

 

• list address = address where data resides

 

• uniflag = indicates unicode; 0 - No unicode, 1 - Uses unicode

 

• primary data = the "key" data column. The information in this column provides

 

each row with its uniqueness.

 

• data2 = variable, column data information. The number of data fields is

 

limited only to the number of columns in the data list.

 

Example:

 

SEND_COMMAND Device,"'^LDA-1,0,Entry5,Meatloaf,Best

 

of,Anything for Love'"

 

Adds a text row to the data list located at address 1. The primary data is set as

 

Entry5. Meatloaf, Best of, and Anything for Love are all cells within the new

 

row.

 

Example (unicode):

 

SEND_COMMAND Device,"'^LDA-

 

1,1,0045006E0074007200790035,004D006500610074006C006F006

 

10061,00420065007300740020006F0066,0041006E0079007400680

 

069006E006700200066006F00720020004C006F00760065'"

 

Adds a unicode text row to the data list located at address 1. The primary data

 

is set as Entry5. Meatloaf, Best of, and Anything for Love are all cells within the

 

new row.

 

 

^LDR

Syntax:

Removes a row from an

SEND_COMMAND <DEV>,"'^LDR-<list

existing data list

address>,<uniflag>,<primary data>'"

 

Variables:

 

• list address = address where data resides

 

• uniflag = indicates unicode; 0 - No unicode, 1 - Uses unicode

 

• primary data = the "key" data column. The information in this column provides

 

each row with its uniqueness.

 

Example:

 

SEND_COMMAND Device,"'^LDR-1,0,Entry5'"

 

Removes the text row with primary data Entry5 from an existing data list at

 

address 1.

 

 

^LDC

Syntax:

Clears all rows in a given list

"'^LDC-<list address>'"

 

Variables:

 

• list address = address where data resides

 

Example:

 

SEND_COMMAND Device, "'^LDC-1'"

 

Clears all rows in data list located at address 1.

 

 

82

Mio Modero R-4

Image 88
Contents Mio Modero R-4 AMX Limited Warranty and Disclaimer Table of Contents Programming the Mio R-4 Getting The Most From Your Mio Modero R-4 Table of Contents Mio R-4 Mio Modero R-4 Remote OverviewMio R-4 FG148-04 Specifications SpecificationsTouch And Tilt Sensor Device Navigation FeaturesFCC Compliance Mio Modero R-4 Remote Mio R-4 Setup Battery Low Indicator Installing Supported Language KeypadsMio R-4 Setup Mio R-4 Setup Mio Modero R-4 Device Setup Pages Accessing the Setup PagesViewing Project Information Project InformationProject Information Remote & Display Settings Remote & Display SettingsChanging the remote timeout Sleep on Display Timeout enabledSetting the Home Hold Time Raising and lowering the LCD brightnessRaising and lowering the charge LED brightness Changing the remote inactivity page flipChecking remote display settings Date/Time Settings Setting the time formatDate/Time Settings Getting time and date from your NetLinx MasterSetting the date Setting the date formatSetting the time Sound Settings Setting the volumeTesting the sound settings Sound SettingsBattery Settings Battery SettingsChecking Dock Status Toggling Brightness LimitProtected Settings Menu Protected Settings MenuPassword Entry Entering a numeric passwordEntering an alphanumeric password Password ConfirmationOptions & Recovery Options & RecoveryChecking the device number Toggling the Function Show optionToggling the Page Tracking option Resetting System SettingsRemoving User Pages Protection ProtectionEdit Passwords Changing the device passwordCalibrate Calibrating the touch screen areaSystem Settings Checking connection statusStatus Master ConnectionChecking the master IP address Checking the gateway IP addressChecking the gateway EUI address Checking the PAN IDSelect System Settings in the Protected Settings Menu Changing the Master Connection TypeSite Survey Joining a wireless networkSite Survey Rebooting the device RebootTest Pages Using the Programming Jack on the Mio R-4 Programming the Mio R-4Updating Firmware Downloading Configuration Files through TPDesign4Updating Mio R-4 Firmware Through USB USB Programming the Mio R-4 RGB triplets and names for basic 88 colors Programming NumbersRGB Values for all 88 Basic Colors RGB Values for all 88 Basic Colors Fixed Fonts and ID numbers Fixed Fonts and ID NumbersSlider/Cursor Names Border Styles by NumbersSlider/Cursor Names Border Styles by NumbersTPD4 Border Styles by Name Text Effects Names Text EffectsSENDCOMMANDs CommandsCommands @APG@DPG @PDR@PHE @PHP@PHT @PPA@PPF @PPG@PPM @PPK@PPN @PPT @PPX@PSE @PSPPpog PpofPpon Button Commands with Embedded Codes Button Commands with Embedded CodesBMF BMF-vt addr range,button states range,dataCont Button Commands Button CommandsANI APFBAU BATBCB BCF Sendcommand Device,BCT-500.504&510,1,12BCT BFB BDOBIM Sendcommand Device,BMC-150,1,1,315,1,%BR%FT%TX%BM%IC%CF%CT BMCZero can be used for an absolute position Sendcommand Device,BMF-500,1,%B10%CFRed%CB Blue Sendcommand Device,BMI-530,1&2,newMac.pngCTBlack%Ptest.png BMIBOR BMPBPP BRD BSFBSM BSPBWW CPFDPF ENAFON GDIGIV GLHGLL GRDGRU GSCSendcommand Device,ICO-500.504&510.515,1&2,1 GSNGSN-vt addr range,bargraph slider name ICOJSB JSISHO JSTTEC TXT TEFUNI Button Query Commands Field Description?Button Query Commands Send Command Device,?BCB-529,1Send Command Device,?BCF-529,1 ?BCB? Button Query Commands Send Command Device,?BCT-529,1Send Command Device,?BMP-529,1 ?BCTSend Command Device,?BOP-529,1 Send Command Device,?BRD-529,1?BOP ?BRDSend Command Device,?BWW-529,1 Send Command Device,?FON-529,1?BWW ?FONSend Command Device,?ICO-529,1 Send Command Device,?JSB-529,1?ICO ?JSBSend Command Device,?JSI-529,1 Send Command Device,?JST-529,1?JSI ?JSTSend Command Device,?TEC-529,1 Send Command Device,?TEF-529,1?TEC ?TEFSend Command Device,?TXT-529,1 ?TXTPanel Run Time Commands Panel Run Time CommandsAkeyr @AKP@AKR BeepSetup Dbeep@EKP PkeypSleep @TKPTpageon TpageoffRemote Runtime Commands Remote Runtime CommandsInput Commands Panel Setup CommandsInput Commands Panel Setup CommandsRemote Setup Commands Remote Setup CommandsList Box Commands List Box CommandsSendcommand Device, LDN-5,1,4,my songs ListboxesSendcommand DEV,LDA-list Sendcommand Device,LDA-1,0,Entry5,Meatloaf,BestSendcommand Device,LDA Sendcommand DEV,LDR-listSendcommand Device, LDD-1 Sendcommand DEV,LDT-listSendcommand Device,LDT-1,1,0,0,0 Sendcommand DEV,LDL-listSendcommand DEV,LVC-view Sendcommand Device,LVC-3,5,2,1Sendcommand DEV,LVF-view Sendcommand Device,LVF-1,0,2,SmithSendcommand DEV,LVM-view address,offset Sendcommand Device,LVM-2,-4Sendcommand DEV,LVO-view address,sort Sendcommand Device,LVO-1,7Sendcommand DEV,LVP-view address,index Sendcommand Device,LVP-5,3Sendcommand DEV,LVS-view Sendcommand Device,LVS-3,5,2,1List Box Command My Music Track Artist Album Title Channel NumberList Box Command My Music with Changes ’LDR-1,0,4’Getting The Most From Your Mio Modero R-4 Getting the Most From the Mio R-4Getting The Most From Your Mio Modero R-4 ZigBee Network Calculator ZigBee Network CalculatorMio Modero R-4 Return Button Specifications Mio Remote Charging BaseMio-RCC Remote Charging Base FG147-02 Specifications Charging The Mio Remote with Charging BaseMio Remote Charging Base Mio Modero R-4 It’s Your World Take Control