3M 78-8135-4385-3-A manual Connector Mounting

Page 12

11.5Using the 3MStripping Tool 6365-ST, remove the buffer in small increments until 21–22 mm (approx. 7/8") of buffer is left.

11.6Using a lint-free cloth moistened with isopropyl alcohol, clean the bare fiber to remove any oils or acrylate coating debris.

11.7Check the final strip lengths and adjust if necessary.

12.0Connector Mounting

12.1While connector is still in oven, mount fiber into

connector inserting until buffer stops inside the connector. Be sure to insert fiber within the guide tube at the rear of the connector.

Note: Removing the connector holder from the oven prior to fiber insertion will cause adhesive to thicken rapidly, greatly limiting the time to insert the fiber.

Cable jackets should be approximately 1mm from the rear of crimp area when buffer is correctly located.

IMPORTANT: Do not lift the connector while in the load adapter during the heating process. This will prevent adhesive from bonding to the load adapter. If adhesive does adhere itself to the inside of the load adapter, use the cleaning pin to remove adhesive prior to inserting next connector. Use alcohol with the pin, if needed.

Note: To ease fiber insertion, make sure fiber is kept very straight when mounting. If resistance is felt when within 1/8” of buffer, you are stubbing and should back out a short distance and re-enter making sure that the fiber is kept straight at all times.

12

78-8135-4385-3-A

Image 12
Contents LC Hot Melt Fiber Optic Connectors Contents Safety and Helpful Hints Hot Melt Oven Safety Information3M LC Expansion 6650-LC Kit Contents 3M LC Connectors C DSetup C D E78-8135-4385-3-A 900 micron Cable Connector Preparation 1.6 2.0 mm Jacketed Cable Connector Preparation3.0 mm Jacketed Cable Connector Preparation Strip Guide Stripping Procedure for 900 micron Fiber Stripping Procedure for 1.6 2.0 mm Jacketed Fiber78-8135-4385-3-A Stripping Procedure for 3 mm Jacketed Fiber Connector Mounting CAUTION Boot Placement for 900 micron Fiber Crimping and Boot Placement for 1.6 2.0 mm Jacketed Fiber78-8135-4385-3-A Crimping and Boot Placement for 3 mm Jacketed Fiber Scribing Multimode Polish 78-8135-4385-3-A 78-8135-4385-3-A Singlemode Polish to -40db 78-8135-4385-3-A Singlemode Polish to -55db Installing Duplex Yokes Finishing78-8135-4385-3-A 22.0 3M Expansion Kit 6650-LC and Replacement Part Numbers 80-6113-1355-478-8135-4385-3-A Communication Markets Division 3M Telecommunications