14.3Using the die labeled “A” with the 3M lettering facing to the left, crimp the metal portion of the sleeve once.

Note: Crimp sleeve must be bottomed against connector prior to crimping. The 3M lettered side of the crimp die should be touching the rear of the connector.

14.4Place the crimp/shrink tube in the shrink fixture assembly and heat for 8 to 10 seconds. Tube should shrink snug around the jacket. Rotate, if needed, to complete shrink.

14.5 Slide boot over crimp/shrink tube.

Note: Jacketed boots appear the same in the photos but the boots for all 3 types of connectors are different sizes and can not be interchanged.

78-8135-4385-3-A

15

Image 15
Contents LC Hot Melt Fiber Optic Connectors Contents Hot Melt Oven Safety Information Safety and Helpful Hints3M LC Expansion 6650-LC Kit Contents C D 3M LC ConnectorsC D E Setup78-8135-4385-3-A 900 micron Cable Connector Preparation 1.6 2.0 mm Jacketed Cable Connector Preparation3.0 mm Jacketed Cable Connector Preparation Stripping Procedure for 1.6 2.0 mm Jacketed Fiber Strip Guide Stripping Procedure for 900 micron Fiber78-8135-4385-3-A Stripping Procedure for 3 mm Jacketed Fiber Connector Mounting CAUTION Crimping and Boot Placement for 1.6 2.0 mm Jacketed Fiber Boot Placement for 900 micron Fiber78-8135-4385-3-A Crimping and Boot Placement for 3 mm Jacketed Fiber Scribing Multimode Polish 78-8135-4385-3-A 78-8135-4385-3-A Singlemode Polish to -40db 78-8135-4385-3-A Singlemode Polish to -55db Finishing Installing Duplex Yokes78-8135-4385-3-A 80-6113-1355-4 22.0 3M Expansion Kit 6650-LC and Replacement Part Numbers78-8135-4385-3-A Communication Markets Division 3M Telecommunications