13.0Boot Placement for 900 micron Fiber

13.1Remove connector from the load adapter and slide the

boot over connector until fully seated.

IMPORTANT: Remove connector gently so that you don’t break the fiber. If connector sticks to the sides of the load adapter when trying to remove, re-heat the connector slightly until connector can be removed from the load adapter. Use the cleaning pin furnished in the kit to scrape the adhesive out of the load adapter hole before proceeding with next connector.

14.0Crimping and Boot Placement for 1.6 – 2.0 mm Jacketed Fiber

14.1Slide crimp/shrink tube down and over aramid yarn.

14.2 Remove the connector from the load adapter.

14

78-8135-4385-3-A

Image 14
Contents LC Hot Melt Fiber Optic Connectors Contents Safety and Helpful Hints Hot Melt Oven Safety Information3M LC Expansion 6650-LC Kit Contents 3M LC Connectors C DSetup C D E78-8135-4385-3-A 3.0 mm Jacketed Cable Connector Preparation 900 micron Cable Connector Preparation1.6 2.0 mm Jacketed Cable Connector Preparation Strip Guide Stripping Procedure for 900 micron Fiber Stripping Procedure for 1.6 2.0 mm Jacketed Fiber78-8135-4385-3-A Stripping Procedure for 3 mm Jacketed Fiber Connector Mounting CAUTION Boot Placement for 900 micron Fiber Crimping and Boot Placement for 1.6 2.0 mm Jacketed Fiber78-8135-4385-3-A Crimping and Boot Placement for 3 mm Jacketed Fiber Scribing Multimode Polish 78-8135-4385-3-A 78-8135-4385-3-A Singlemode Polish to -40db 78-8135-4385-3-A Singlemode Polish to -55db Installing Duplex Yokes Finishing78-8135-4385-3-A 22.0 3M Expansion Kit 6650-LC and Replacement Part Numbers 80-6113-1355-478-8135-4385-3-A Communication Markets Division 3M Telecommunications