3M 78-8135-4385-3-A manual Strip Guide Stripping Procedure for 900 micron Fiber

Page 9

8.0 Strip Guide

9.0Stripping Procedure for 900 micron Fiber

9.1Place the cable on the strip template. Mark buffer

at 11 mm. Using the 3MStripping Tool 6365-ST, remove the buffer in small increments until 11 mm of buffer has been removed.

9.2Using a lint-free cloth moistened with isopropyl alcohol, clean the bare fiber to remove any oils or acrylate coating debris.

9.3Check the final strip length and adjust if necessary.

10.0Stripping Procedure for 1.6 – 2.0 mm Jacketed Fiber

10.1Place the jacketed fiber on the strip template and use

a fiber marking pen to mark the location of the jacket cut. Using the 3MStripping Tool 6365-ST, remove 33 mm (1 1/3") of jacket off cable.

��������������

�������������

�����

������

78-8135-4385-3-A

9

Image 9
Contents LC Hot Melt Fiber Optic Connectors Contents Hot Melt Oven Safety Information Safety and Helpful Hints3M LC Expansion 6650-LC Kit Contents C D 3M LC ConnectorsC D E Setup78-8135-4385-3-A 900 micron Cable Connector Preparation 1.6 2.0 mm Jacketed Cable Connector Preparation3.0 mm Jacketed Cable Connector Preparation Stripping Procedure for 1.6 2.0 mm Jacketed Fiber Strip Guide Stripping Procedure for 900 micron Fiber78-8135-4385-3-A Stripping Procedure for 3 mm Jacketed Fiber Connector Mounting CAUTION Crimping and Boot Placement for 1.6 2.0 mm Jacketed Fiber Boot Placement for 900 micron Fiber78-8135-4385-3-A Crimping and Boot Placement for 3 mm Jacketed Fiber Scribing Multimode Polish 78-8135-4385-3-A 78-8135-4385-3-A Singlemode Polish to -40db 78-8135-4385-3-A Singlemode Polish to -55db Finishing Installing Duplex Yokes78-8135-4385-3-A 80-6113-1355-4 22.0 3M Expansion Kit 6650-LC and Replacement Part Numbers78-8135-4385-3-A Communication Markets Division 3M Telecommunications