4.4Insert the connector into the hot melt connector holder.
4.5Place the load adapter, with slot aligned with handle, into an available port in the oven.
IMPORTANT: Do not place connector in a hot load adapter. This may cause adhesive to flow to the outside of the ferrule. Load adapter should be at room temperature when connector is inserted.
4.6The 3M™ LC Hot Melt Connector should be in the oven for at least 75 seconds. The connector should not be in the oven longer than 5 minutes.
4.7Place the heat shrink fixture in an available port in the oven.
Note: This step is only necessary for use with the