Bosch Appliances DVR 440, DVR 480 operation manual 5Ethernet connection, Lantx, Lanrx +

Page 24

24 en Hardware setupDigital Video Recorder 440/480 Series

4.5Ethernet connection

The standard RJ-45 Ethernet socket is used to connect the unit directly to a PC or to a network. To connect directly to a network hub, use a straight-through network cable. To connect directly to a PC, use a cross-over network cable. Consult with your local IT personnel for the specific type of cable needed. The maximum cable length from node to node is limited to 100 meters (300 feet).

Specifications

Connection: 10/100 BaseT, IEEE 802.3

Differential signal voltage: ± 2.8 V maximum, inputs have transient overvoltage protection

Ethernet port details: EEE 802.3/802.3u — 100Base-TX/10Base-T physical layer

Auto negotiation: 10/100, full/half duplex

Cable length: 100 meters (100 ohm unshielded twisted pair cable or 150 ohm shielded twisted pair cable, category 5 or higher).

Impedance: built-in compensation for impedance matching

Indicators: ACT, 10/100

Figure 4.6

RJ-45 Ethernet connector

 

 

 

 

Signal name

Pin number

Description

 

 

 

 

LAN_TX +

 

1

Ethernet transmit line plus

 

 

 

 

LAN_TX -

 

2

Ethernet transmit line minus

 

 

 

LAN_RX +

3

Ethernet receive line plus

 

 

 

 

N/C

 

4

No connection

 

 

 

 

N/C

 

5

No connection

 

 

 

 

LAN_RX -

 

6

Ethernet receive line minus

 

 

 

 

N/C

 

7

No connection

 

 

 

 

N/C

 

8

No connection

 

 

 

 

Table 4.2

LAN - RJ-45 Ethernet socket

 

AM18-Q0605 v2.0 2012.04

Installation and Operation manual

Bosch Security Systems

Image 24
Contents Digital Video Recorder 440/480 Series Page Table of Contents Maintenance Configuration menuCamera Maximum frame rates DVR Video adjustment Operating instructionsTCP/IP DdnsNTP Web Client SoftwareMenu default values Technical specifications Appendix1Safety Safety precautionsImportant safety instructions En Safety Digital Video Recorder 440/480 Series Important Notices Coax groundingRack-mount FCC and UL FCC InformationBosch notices CopyrightTrademarks More informationIntroduction Digital video recorder applicationsVersions ManualsFeatures Package contentsUnpacking Installation environment 5WarrantyAssociated equipment Quick install Powering upConnections Primary connectionsFirst-time use NavigatingQuick install menu InternationalQuick install Continuous Recording Continuous Recording3Network IP address, SubnetMask, and Gateway Hardware setup SpecificationsCamera connections Audio connectionsMonitors or larger when using LCDs Monitor connectionsVGA Monitor a 2CVBSSignal name Pin number Description 4RS-232 COM port connectionsRTS CTS5Ethernet connection LantxLanrx + 6USB connectors RS485 portGND 8External alarm I/O connection Connecting the inputsConnecting the alarm output 9Power supply 10MaintenanceOperating instructions View live Yes Sequence QuadOSD Front panel controls 1KeysArrow keys AM18-Q0605 v2.0 Bosch Security Systems 2Indicators Remote control Mouse ControlsKey. To close the System Control Bar press the exit Viewing pictures Monitor aMonitor B 3Viewing Freeze image ZoomLive mode Playback modeAdministrator. To enter playback mode To switch the unit from live to playback modeAccess using the front panel keys Access using the mouseOverview of the menu system System Control Bar appears on monitor aMain menu 7Search Main menu Search Bosch Security Systems AM18-Q0605 v2.0Date/time search Event search Search criteriaSearch results Event Search resultsSmart search Smart Search results8Export 10 Export menuSystem information 11 System Control Bar System information12 System Control Bar Video signals information 13 System Control Bar Disk info 10Log Logbook filterTriggers and alarms Alarm inputsVideo loss alarm Multiple alarmsMotion events Configuration menu System Configuration menuTop tabs Submenus Camera 1Camera 1CameraVideo adjustment Channels EnabledMaximum frame rates DVR Channel5PTZ Camera PTZCamera Continuous Recording Use the same procedure as in Continuous Recording Input RecordingPre-event Post-eventUse the same procedure as in Input Recording Motion RecordingNetwork Live Streaming 25/30Video format Camera Video formatSetting the dynamic characteristics 2Schedule1Schedule Use the same procedure as Monitor a 3Display1Language Exception days4Event 1InputInput Type Relay output2Motion 13 Event MotionAlarm acknowledge 14 Event Alarm acknowledgeRelay outputs can be configured to react to system events System menu5Network 1TCP/IP2Streaming to mobile devices 3Connecting using a smart mobile phone 4DDNS 5Notification6Mail 6System 1Date/Time2NTP 3BeeperAdmin 4UsersGeneral User 1, 25Configuration 23 System ConfigurationHard Disk 24 System Hard disk7System 25 System SystemConnecting to the DVR 400 Series the first time Web Client SoftwareGetting started System requirementsHow to log on Settings behave differently because of the Web BrowserMenu structure differences Maximum number of usersLive mode Introducing the browser windowPTZ camera control Pan and tiltAux commands Camera viewsZoom, focus, and iris Pre-positionPlayback mode Web Client Playback Bosch Security Systems AM18-Q0605 v2.0Export mode Web Client Export AM18-Q0605 v2.0 Bosch Security SystemsConfiguration mode Installation Archive PlayerStarting the Program Authenticity of the archived videoTo switch the display mode Introducing the main windowCamera Views Open buttonUsing the playback controls Viewing ImagesAssigning Cameos Find image Video slider barChecking authenticity Exit buttonMenu default values Navigation Setting Default value ResetNavigation Setting Default value Reset TCP/IP Dhcp Rtsp PortIcmp EmptyAdministrator YYYY/MM/DDDVR ID Technical specifications 10.1 Electrical10.1.1 Mechanical 10.1.2 EnvironmentalStorage Display ModesElectromagnetic and Safety 10.2 USB memory sticksEMC requirements USAAppendix Software licensesBosch software Other licenses copyright noticesWarranties and disclaimer of warranties Source licenseRelevant open source software can be found at InformationPage Bosch Security Systems