Bosch Appliances DVR 480, DVR 440 operation manual Viewing pictures, Monitor a, Monitor B

Page 33

Digital Video Recorder 440/480 SeriesOperating instructions en 33

5.4

Viewing pictures

 

 

The unit has two monitor outputs, A and B. The way in which these monitors display pictures

 

depends on how the system is configured.

5.4.1

Monitor A

 

 

 

Monitor A is the main monitor. It shows full-screen, quad or multiscreen live or playback

 

camera pictures. Status messages, alarms, motion, and video loss warnings are also displayed

 

on this monitor. When the menu system is activated, it is displayed on this monitor. Monitor A

 

is the default monitor for keyboard and mouse commands.

 

Changing the full-screen display on Monitor A

 

To control the display on monitor A with mouse control:

 

1. Display the System Control Bar.

 

2.

Click

.

 

 

3.

From the pop-up menu, select the display for Monitor A

 

 

– Select 1-4/8 for the corresponding Camera

 

 

– Select the sequence

key to sequence channels 1-4/8

Changing the quad/3x3 display on Monitor A

 

To control the quad/3x3 display on monitor A with mouse control:

 

1.

Display the System Control Bar.

 

 

2.

Click

.

 

 

 

 

 

 

 

 

3.

From the pop-up menu, select the display for Monitor A

 

 

– Select the quad key

to select the quad mode

 

 

– Select the multiscreen key

 

 

 

 

 

to select the 3x3 mode (DVR 480 only)

 

 

Select the sequence

key to sequence the quad mode

5.4.2

Monitor B

 

 

 

 

 

 

 

 

 

Monitor B displays full-screen, quad or multiscreen (with or without sequence) of live

 

pictures. When an alarm or motion input is detected, the camera picture with the Alarm/

 

Motion indicator can be displayed on monitor B. When multiple alarms or motion occur,

 

camera pictures are sequenced on monitor B.

 

Changing the full-screen display on Monitor B

 

To control the display on monitor B with mouse control:

 

1.

Bring up the System Control Bar.

 

 

2.

Click the Monitor B

button.

 

 

3.

From the pop-up menu, select the display for Monitor B

 

 

– Select 1-8/16 for the corresponding Camera

 

 

Select the sequence

key to sequence channels 1-8/16

Changing the quad display on Monitor B

To control the quad display on monitor B with mouse control:

1.Bring up the System Control Bar.

2.Click the Monitor B button.

Bosch Security Systems

Installation and Operation manual

AM18-Q0605 v2.0 2012.04

Image 33
Contents Digital Video Recorder 440/480 Series Page Table of Contents Configuration menu MaintenanceCamera Maximum frame rates DVR Video adjustment Operating instructionsDdns TCP/IPNTP Web Client SoftwareAppendix Menu default values Technical specifications1Safety Safety precautionsImportant safety instructions En Safety Digital Video Recorder 440/480 Series Coax grounding Important NoticesRack-mount FCC Information FCC and ULCopyright Bosch noticesTrademarks More informationDigital video recorder applications IntroductionVersions ManualsFeatures Package contentsUnpacking Installation environment 5WarrantyAssociated equipment Powering up Quick installConnections Primary connectionsNavigating First-time useInternational Quick install menuContinuous Recording Quick install Continuous Recording3Network IP address, SubnetMask, and Gateway Specifications Hardware setupCamera connections Audio connectionsMonitor connections Monitors or larger when using LCDsVGA Monitor a 2CVBS4RS-232 COM port connections Signal name Pin number DescriptionRTS CTS5Ethernet connection LantxLanrx + 6USB connectors RS485 portGND 8External alarm I/O connection Connecting the inputsConnecting the alarm output 10Maintenance 9Power supplyOperating instructions View live Yes Sequence QuadOSD Front panel controls 1KeysArrow keys AM18-Q0605 v2.0 Bosch Security Systems 2Indicators Remote control Mouse ControlsKey. To close the System Control Bar press the exit Viewing pictures Monitor aMonitor B 3Viewing Zoom Freeze imagePlayback mode Live modeAdministrator. To enter playback mode To switch the unit from live to playback modeAccess using the mouse Access using the front panel keysOverview of the menu system System Control Bar appears on monitor aMain menu Main menu Search Bosch Security Systems AM18-Q0605 v2.0 7SearchDate/time search Search criteria Event searchSearch results Event Search resultsSmart Search results Smart search10 Export menu 8Export11 System Control Bar System information System information12 System Control Bar Video signals information 13 System Control Bar Disk info Logbook filter 10LogAlarm inputs Triggers and alarmsVideo loss alarm Multiple alarmsMotion events System Configuration menu Configuration menuTop tabs Submenus Camera 1Camera 1CameraChannels Enabled Video adjustmentMaximum frame rates DVR ChannelCamera PTZ 5PTZCamera Continuous Recording Input Recording Use the same procedure as in Continuous RecordingPre-event Post-eventMotion Recording Use the same procedure as in Input Recording25/30 Network Live StreamingCamera Video format Video formatSetting the dynamic characteristics 2Schedule1Schedule 3Display Use the same procedure as Monitor a1Language Exception days1Input 4EventInput Type Relay output13 Event Motion 2Motion14 Event Alarm acknowledge Alarm acknowledgeSystem menu Relay outputs can be configured to react to system events5Network 1TCP/IP2Streaming to mobile devices 3Connecting using a smart mobile phone 5Notification 4DDNS6Mail 1Date/Time 6System2NTP 3Beeper4Users AdminGeneral User 1, 223 System Configuration 5Configuration24 System Hard disk Hard Disk25 System System 7SystemWeb Client Software Connecting to the DVR 400 Series the first timeGetting started System requirementsSettings behave differently because of the Web Browser How to log onMenu structure differences Maximum number of usersIntroducing the browser window Live modePTZ camera control Pan and tiltCamera views Aux commandsZoom, focus, and iris Pre-positionWeb Client Playback Bosch Security Systems AM18-Q0605 v2.0 Playback modeWeb Client Export AM18-Q0605 v2.0 Bosch Security Systems Export modeConfiguration mode Archive Player InstallationStarting the Program Authenticity of the archived videoIntroducing the main window To switch the display modeCamera Views Open buttonUsing the playback controls Viewing ImagesAssigning Cameos Video slider bar Find imageChecking authenticity Exit buttonNavigation Setting Default value Reset Menu default valuesNavigation Setting Default value Reset Rtsp Port TCP/IP DhcpIcmp EmptyAdministrator YYYY/MM/DDDVR ID 10.1 Electrical Technical specifications10.1.2 Environmental 10.1.1 MechanicalStorage Display Modes10.2 USB memory sticks Electromagnetic and SafetyEMC requirements USASoftware licenses AppendixBosch software Other licenses copyright noticesSource license Warranties and disclaimer of warrantiesRelevant open source software can be found at InformationPage Bosch Security Systems