Bosch Appliances DVR 480, DVR 440 1Safety, Safety precautions, Important safety instructions

Page 7

Digital Video Recorder 440/480 Series

Safety en

7

 

 

 

1Safety

1.1

Safety precautions

DANGER!

High risk: This symbol indicates an imminently hazardous situation such as "Dangerous

Voltage" inside the product.

If not avoided, this will result in an electrical shock, serious bodily injury, or death.

WARNING!

Medium risk: Indicates a potentially hazardous situation.

If not avoided, this could result in minor or moderate bodily injury.

CAUTION!

Low risk: Indicates a potentially hazardous situation.

if not avoided, this could result in property damage or risk of damage to the unit.

1.2

Important safety instructions

Read, follow, and retain for future reference all of the following safety instructions. Heed all warnings on the unit and in the operating instructions before operating the unit.

1.Cleaning - Unplug the unit from the outlet before cleaning. Follow any instructions provided with the unit. Generally, using a dry cloth for cleaning is sufficient but a moist, fluff-free cloth or leather shammy may also be used. Do not use liquid cleaners or aerosol cleaners.

2.Heat Sources - Do not install the unit near any heat sources such as radiators, heaters, stoves, or other equipment (including amplifiers) that produce heat.

3.Ventilation - Any openings in the unit enclosure are provided for ventilation to prevent overheating and ensure reliable operation. Do not block or cover these openings. Do not place the unit in an enclosure unless proper ventilation is provided, or the manufacturer's instructions have been adhered to.

4.Water - Do not use this unit near water, for example near a bathtub, washbowl, sink, laundry basket, in a damp or wet basement, near a swimming pool, in an outdoor installation, or in any area classified as a wet location. To reduce the risk of fire or electrical shock, do not expose this unit to rain or moisture.

5.Object and liquid entry - Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electrical shock. Never spill liquid of any kind on the unit. Do not place objects filled with liquids, such as vases or cups, on the unit.

6.Lightning - For added protection during a lightning storm, or when leaving this unit unattended and unused for long periods, unplug the unit from the wall outlet and disconnect the cable system. This will prevent damage to the unit from lightning and power line surges.

7.Controls adjustment - Adjust only those controls specified in the operating instructions. Improper adjustment of other controls may cause damage to the unit. Use of controls or adjustments, or performance of procedures other than those specified, may result in hazardous radiation exposure.

8.Overloading - Do not overload outlets and extension cords. This can cause fire or electrical shock.

Bosch Security Systems

Installation and Operation manual

AM18-Q0605 v2.0 2012.04

Image 7
Contents Digital Video Recorder 440/480 Series Page Table of Contents Operating instructions MaintenanceConfiguration menu Camera Maximum frame rates DVR Video adjustmentWeb Client Software TCP/IPDdns NTPAppendix Menu default values Technical specificationsSafety precautions 1SafetyImportant safety instructions En Safety Digital Video Recorder 440/480 Series Coax grounding Important NoticesRack-mount FCC Information FCC and ULMore information Bosch noticesCopyright TrademarksManuals IntroductionDigital video recorder applications VersionsPackage contents FeaturesUnpacking 5Warranty Installation environmentAssociated equipment Primary connections Quick installPowering up ConnectionsNavigating First-time useInternational Quick install menuContinuous Recording Quick install Continuous RecordingIP address, Subnet 3NetworkMask, and Gateway Audio connections Hardware setupSpecifications Camera connections2CVBS Monitors or larger when using LCDsMonitor connections VGA Monitor aCTS Signal name Pin number Description4RS-232 COM port connections RTSLantx 5Ethernet connectionLanrx + RS485 port 6USB connectorsGND Connecting the inputs 8External alarm I/O connectionConnecting the alarm output 10Maintenance 9Power supplyView live Yes Sequence Quad Operating instructionsOSD 1Keys Front panel controlsArrow keys AM18-Q0605 v2.0 Bosch Security Systems 2Indicators Mouse Controls Remote controlKey. To close the System Control Bar press the exit Monitor a Viewing picturesMonitor B 3Viewing Zoom Freeze imageTo switch the unit from live to playback mode Live modePlayback mode Administrator. To enter playback modeSystem Control Bar appears on monitor a Access using the front panel keysAccess using the mouse Overview of the menu systemMain menu Main menu Search Bosch Security Systems AM18-Q0605 v2.0 7SearchDate/time search Event Search results Event searchSearch criteria Search resultsSmart Search results Smart search10 Export menu 8Export11 System Control Bar System information System information12 System Control Bar Video signals information 13 System Control Bar Disk info Logbook filter 10LogAlarm inputs Triggers and alarmsMultiple alarms Video loss alarmMotion events System Configuration menu Configuration menuTop tabs Submenus Camera 1Camera 1CameraChannel Video adjustmentChannels Enabled Maximum frame rates DVRCamera PTZ 5PTZCamera Continuous Recording Post-event Use the same procedure as in Continuous RecordingInput Recording Pre-eventMotion Recording Use the same procedure as in Input Recording25/30 Network Live StreamingCamera Video format Video format2Schedule Setting the dynamic characteristics1Schedule Exception days Use the same procedure as Monitor a3Display 1LanguageRelay output 4Event1Input Input Type13 Event Motion 2Motion14 Event Alarm acknowledge Alarm acknowledgeSystem menu Relay outputs can be configured to react to system events1TCP/IP 5Network2Streaming to mobile devices 3Connecting using a smart mobile phone 5Notification 4DDNS6Mail 3Beeper 6System1Date/Time 2NTPUser 1, 2 Admin4Users General23 System Configuration 5Configuration24 System Hard disk Hard Disk25 System System 7SystemSystem requirements Connecting to the DVR 400 Series the first timeWeb Client Software Getting startedMaximum number of users How to log onSettings behave differently because of the Web Browser Menu structure differencesPan and tilt Live modeIntroducing the browser window PTZ camera controlPre-position Aux commandsCamera views Zoom, focus, and irisWeb Client Playback Bosch Security Systems AM18-Q0605 v2.0 Playback modeWeb Client Export AM18-Q0605 v2.0 Bosch Security Systems Export modeConfiguration mode Authenticity of the archived video InstallationArchive Player Starting the ProgramOpen button To switch the display modeIntroducing the main window Camera ViewsViewing Images Using the playback controlsAssigning Cameos Exit button Find imageVideo slider bar Checking authenticityNavigation Setting Default value Reset Menu default valuesNavigation Setting Default value Reset Empty TCP/IP DhcpRtsp Port IcmpYYYY/MM/DD AdministratorDVR ID 10.1 Electrical Technical specificationsDisplay Modes 10.1.1 Mechanical10.1.2 Environmental StorageUSA Electromagnetic and Safety10.2 USB memory sticks EMC requirementsOther licenses copyright notices AppendixSoftware licenses Bosch softwareInformation Warranties and disclaimer of warrantiesSource license Relevant open source software can be found atPage Bosch Security Systems