Bosch Appliances DVR 480 3Display, 1Language, Exception days, Select a Language from the list

Page 61

Digital Video Recorder 440/480 Series

Configuration menu en 61

 

 

2.Move to the next chronological mode change and press the enter key to cycle to the next mode.

Use Day copy to copy the settings of the schedule to another day.

Use Ch copy to copy the settings of the schedule to another channel.

3.When finished, select Exit to save the updated schedule.

Exception days

Up to 32 exceptions can be set that override the schedule.

To add an exception, select Add. Choose the date from the Calendar.

To edit an exception, select List and then select the value to edit.

To remove an exception, select List and click the Delete button.

6.3Display

6.3.1Language

Select a Language from the list.

6.3.2

Monitor A

Figure 6.11 Display - Monitor A

1.Select which items are displayed on Monitor A when the OSD is active.

2.Set the Sequence dwell time for each channel.

The Sequence dwell time is used during Sequence or if multiple active events trigger the monitor.

6.3.3

Monitor B

 

Use the same procedure as Monitor A.

Bosch Security Systems

Installation and Operation manual

AM18-Q0605 v2.0 2012.04

Image 61
Contents Digital Video Recorder 440/480 Series Page Table of Contents Configuration menu MaintenanceCamera Maximum frame rates DVR Video adjustment Operating instructionsDdns TCP/IPNTP Web Client SoftwareAppendix Menu default values Technical specificationsSafety precautions 1SafetyImportant safety instructions En Safety Digital Video Recorder 440/480 Series Coax grounding Important NoticesRack-mount FCC Information FCC and ULCopyright Bosch noticesTrademarks More informationDigital video recorder applications IntroductionVersions ManualsPackage contents FeaturesUnpacking 5Warranty Installation environmentAssociated equipment Powering up Quick installConnections Primary connectionsNavigating First-time useInternational Quick install menuContinuous Recording Quick install Continuous RecordingIP address, Subnet 3NetworkMask, and Gateway Specifications Hardware setupCamera connections Audio connectionsMonitor connections Monitors or larger when using LCDsVGA Monitor a 2CVBS4RS-232 COM port connections Signal name Pin number DescriptionRTS CTSLantx 5Ethernet connectionLanrx + RS485 port 6USB connectorsGND Connecting the inputs 8External alarm I/O connectionConnecting the alarm output 10Maintenance 9Power supplyView live Yes Sequence Quad Operating instructionsOSD 1Keys Front panel controlsArrow keys AM18-Q0605 v2.0 Bosch Security Systems 2Indicators Mouse Controls Remote controlKey. To close the System Control Bar press the exit Monitor a Viewing picturesMonitor B 3Viewing Zoom Freeze imagePlayback mode Live modeAdministrator. To enter playback mode To switch the unit from live to playback modeAccess using the mouse Access using the front panel keysOverview of the menu system System Control Bar appears on monitor aMain menu Main menu Search Bosch Security Systems AM18-Q0605 v2.0 7SearchDate/time search Search criteria Event searchSearch results Event Search resultsSmart Search results Smart search10 Export menu 8Export11 System Control Bar System information System information12 System Control Bar Video signals information 13 System Control Bar Disk info Logbook filter 10LogAlarm inputs Triggers and alarmsMultiple alarms Video loss alarmMotion events System Configuration menu Configuration menuTop tabs Submenus Camera 1Camera 1CameraChannels Enabled Video adjustmentMaximum frame rates DVR ChannelCamera PTZ 5PTZCamera Continuous Recording Input Recording Use the same procedure as in Continuous RecordingPre-event Post-eventMotion Recording Use the same procedure as in Input Recording25/30 Network Live StreamingCamera Video format Video format2Schedule Setting the dynamic characteristics1Schedule 3Display Use the same procedure as Monitor a1Language Exception days1Input 4EventInput Type Relay output13 Event Motion 2Motion14 Event Alarm acknowledge Alarm acknowledgeSystem menu Relay outputs can be configured to react to system events1TCP/IP 5Network2Streaming to mobile devices 3Connecting using a smart mobile phone 5Notification 4DDNS6Mail 1Date/Time 6System2NTP 3Beeper4Users AdminGeneral User 1, 223 System Configuration 5Configuration24 System Hard disk Hard Disk25 System System 7SystemWeb Client Software Connecting to the DVR 400 Series the first timeGetting started System requirementsSettings behave differently because of the Web Browser How to log onMenu structure differences Maximum number of usersIntroducing the browser window Live modePTZ camera control Pan and tiltCamera views Aux commandsZoom, focus, and iris Pre-positionWeb Client Playback Bosch Security Systems AM18-Q0605 v2.0 Playback modeWeb Client Export AM18-Q0605 v2.0 Bosch Security Systems Export modeConfiguration mode Archive Player InstallationStarting the Program Authenticity of the archived videoIntroducing the main window To switch the display modeCamera Views Open buttonViewing Images Using the playback controlsAssigning Cameos Video slider bar Find imageChecking authenticity Exit buttonNavigation Setting Default value Reset Menu default valuesNavigation Setting Default value Reset Rtsp Port TCP/IP DhcpIcmp EmptyYYYY/MM/DD AdministratorDVR ID 10.1 Electrical Technical specifications10.1.2 Environmental 10.1.1 MechanicalStorage Display Modes10.2 USB memory sticks Electromagnetic and SafetyEMC requirements USASoftware licenses AppendixBosch software Other licenses copyright noticesSource license Warranties and disclaimer of warrantiesRelevant open source software can be found at InformationPage Bosch Security Systems