RS485

USB

Storage

Screw terminal output, cable cross section AWG 28-16 (0.08-1.5 mm2)

Type A connector (2)

USB 2.0 on front and rear for mouse and USB memory device

Hard Disks

1 SATA hard drive

Record Rate (IPS)

PAL: 25 total, configurable per camera: 25, 12.5,

 

6.25, 5, 2.5, 1

 

NTSC: 30 total, configurable per camera: 30, 15,

 

7.5, 5, 3, 1

 

 

Record Resolution

4CIF: 704 x 576 PAL - 704 x 480 NTSC

 

2CIF: 704 x 288 PAL - 704 x 240 NTSC

 

CIF: 352 x 288 PAL - 352 x 240 NTSC

Record Quality

Best

 

High

 

Normal

 

Low

 

Lowest

 

 

Display Modes

 

Monitor A

Monitor B

Full, full sequence, quad, alarm call-up (live and playback)

Full, full sequence, alarm call-up (live)

Recording Modes

Linear, continuous

10.1.1

Mechanical

 

 

 

 

 

 

 

Dimensions (excluding cabling)

225 x 325 x 60 mm14.8 x 15 x 2.5 in.

 

 

(W x D x H)

 

 

 

Weight

DVR 440: 2.9 kg (6.39 lb)DVR 480: 3.0 kg (6.6 lb)

10.1.2

Environmental

 

 

 

 

 

 

 

Temperature

Operating: 0 °C to +40 °C (+32 °F to +104 °F)

 

 

 

Storage: -40 °C to +70 °C (-40° F to +158 °F)

 

 

 

 

 

 

Relative humidity

Operating: <93% non-condensing

 

 

 

Storage: <95% non-condensing

 

 

 

 

Bosch Security Systems

Installation and Operation manual

AM18-Q0605 v2.0 2012.04

Image 91
Contents Digital Video Recorder 440/480 Series Page Table of Contents Operating instructions MaintenanceConfiguration menu Camera Maximum frame rates DVR Video adjustmentWeb Client Software TCP/IPDdns NTPAppendix Menu default values Technical specificationsSafety precautions 1SafetyImportant safety instructions En Safety Digital Video Recorder 440/480 Series Coax grounding Important NoticesRack-mount FCC Information FCC and ULMore information Bosch noticesCopyright TrademarksManuals IntroductionDigital video recorder applications VersionsPackage contents FeaturesUnpacking 5Warranty Installation environmentAssociated equipment Primary connections Quick installPowering up ConnectionsNavigating First-time useInternational Quick install menuContinuous Recording Quick install Continuous RecordingIP address, Subnet 3NetworkMask, and Gateway Audio connections Hardware setupSpecifications Camera connections2CVBS Monitors or larger when using LCDsMonitor connections VGA Monitor aCTS Signal name Pin number Description4RS-232 COM port connections RTSLantx 5Ethernet connectionLanrx + RS485 port 6USB connectorsGND Connecting the inputs 8External alarm I/O connectionConnecting the alarm output 10Maintenance 9Power supplyView live Yes Sequence Quad Operating instructionsOSD 1Keys Front panel controlsArrow keys AM18-Q0605 v2.0 Bosch Security Systems 2Indicators Mouse Controls Remote controlKey. To close the System Control Bar press the exit Monitor a Viewing picturesMonitor B 3Viewing Zoom Freeze imageTo switch the unit from live to playback mode Live modePlayback mode Administrator. To enter playback modeSystem Control Bar appears on monitor a Access using the front panel keysAccess using the mouse Overview of the menu systemMain menu Main menu Search Bosch Security Systems AM18-Q0605 v2.0 7SearchDate/time search Event Search results Event searchSearch criteria Search resultsSmart Search results Smart search10 Export menu 8Export11 System Control Bar System information System information12 System Control Bar Video signals information 13 System Control Bar Disk info Logbook filter 10LogAlarm inputs Triggers and alarmsMultiple alarms Video loss alarmMotion events System Configuration menu Configuration menuTop tabs Submenus Camera 1Camera 1CameraChannel Video adjustmentChannels Enabled Maximum frame rates DVRCamera PTZ 5PTZCamera Continuous Recording Post-event Use the same procedure as in Continuous RecordingInput Recording Pre-eventMotion Recording Use the same procedure as in Input Recording25/30 Network Live StreamingCamera Video format Video format2Schedule Setting the dynamic characteristics1Schedule Exception days Use the same procedure as Monitor a3Display 1LanguageRelay output 4Event1Input Input Type13 Event Motion 2Motion14 Event Alarm acknowledge Alarm acknowledgeSystem menu Relay outputs can be configured to react to system events1TCP/IP 5Network2Streaming to mobile devices 3Connecting using a smart mobile phone 5Notification 4DDNS6Mail 3Beeper 6System1Date/Time 2NTPUser 1, 2 Admin4Users General23 System Configuration 5Configuration24 System Hard disk Hard Disk25 System System 7SystemSystem requirements Connecting to the DVR 400 Series the first timeWeb Client Software Getting startedMaximum number of users How to log onSettings behave differently because of the Web Browser Menu structure differencesPan and tilt Live modeIntroducing the browser window PTZ camera controlPre-position Aux commandsCamera views Zoom, focus, and irisWeb Client Playback Bosch Security Systems AM18-Q0605 v2.0 Playback modeWeb Client Export AM18-Q0605 v2.0 Bosch Security Systems Export modeConfiguration mode Authenticity of the archived video InstallationArchive Player Starting the ProgramOpen button To switch the display modeIntroducing the main window Camera ViewsViewing Images Using the playback controlsAssigning Cameos Exit button Find imageVideo slider bar Checking authenticityNavigation Setting Default value Reset Menu default valuesNavigation Setting Default value Reset Empty TCP/IP DhcpRtsp Port IcmpYYYY/MM/DD AdministratorDVR ID 10.1 Electrical Technical specificationsDisplay Modes 10.1.1 Mechanical10.1.2 Environmental StorageUSA Electromagnetic and Safety10.2 USB memory sticks EMC requirementsOther licenses copyright notices AppendixSoftware licenses Bosch softwareInformation Warranties and disclaimer of warrantiesSource license Relevant open source software can be found atPage Bosch Security Systems