Fans stopped; replace them! | This message appears if the fan assembly |
| of the filer stops functioning. Replace the |
| fan assembly as soon as possible. |
|
|
Fault on shelf n | |
| enclosure address number. This message |
| appears when the system detects an error |
| on one or more Dell PowerVault 700N |
| storage systems. Check the LEDs of the |
| specified Dell PowerVault 700N storage |
| systems to see whether a fan or power |
| supply needs to be replaced. Replace the |
| faulty fan or power supply on the Dell |
| |
| needed. |
|
|
Maintenance mode | The system is running in maintenance |
| mode. Refer to the Dell PowerVault 720N, |
| 740N, and 760N System Administrator and |
| Command Reference Guide for more |
| information about maintenance mode. |
|
|
Non Maskable interrupt | This message is usually generated by a |
| correctable (nonfatal) memory error, but |
| might signal other conditions. |
| If this message appears repeatedly, it |
| might indicate a defective memory mod- |
| ule (DIMM). Refer to the console |
| messages or to the /etc/messages file for |
| detailed information. |
|
|
NFS service not enabled | This message appears only if you have |
| licensed NFS. NFS service has been dis- |
| abled either because the system failed to |
| enable it when it started, or because you |
| disabled it with the nfs off command. |
|
|
Parity disk is broken | The parity disk is not operating and the |
| system is in degraded mode. The solution |
| depends on whether a hot spare is |
| installed in the system. Refer to the Dell |
| PowerVault 720N, 740N, and 760N System |
| Administrator and Command Reference |
| Guide for information about replacing a |
| faulty disk. |
|
|