Teledyne Spare Parts & Essential Parts for T201 Maintenance

Page 41

7.0 T201 SPARE PARTS LIST

 

This section lists the spare parts for the T201; however, due to the

 

dynamic nature of spare parts numbers, it is recommended that you refer

 

to our Website or contact Sales for recent updates.

(Reference: 07356 29 March 2012, 12:17PM)

PARTNUMBER

DESCRIPTION

000940100

CD, ORIFICE, .003 GREEN

000940400

CD, ORIFICE, .004 BLUE

000940500

CD, ORIFICE, .007 ORANGE

000940600

CD, ORIFICE, .010 BROWN

002730000

CD, FILTER, 665NM (KB)

005960000

AKIT, EXP, ACT CHARCOAL, (2 BTL@64 FL-OZ EA)

005970000

AKIT, EXP, PURAFIL (2 BTL@64 FL-OZ EA)

009690200

AKIT, TFE FLTR ELEM (FL19,100=1) 47mm

010820000

ASSY, THERMOCOUPLE, HICON

011630000

HVPS INSULATOR GASKET (KB)

013140000

ASSY, COOLER FAN (NOX/SOX)

014080100

ASSY, HVPS, SOX/NOX

018080000

AKIT, DESSICANT BAGGIES, (12)

025070000

ASSY, IZS VALVE HEATER

025250000

ASSY, VALVE/THERM

037860000

ORING, TEFLON, RETAINING RING, 47MM (KB)

039700100

HEATER, BAND, TYPE K, DUAL VOLTAGE(KB)*

040010000

ASSY, FAN REAR PANEL (B/F)

040030800

PCA, PRESS SENSORS (2X), FLOW, (NOX)

040400000

ASSY, HEATERS/THERMAL SWITCH, RX CELL

041800500

PCA, PMT PREAMP, VR

041920000

ASSY, THERMISTOR

042680100

ASSY, VALVE (SS)

043220000

TUBING, CERAMIC, .25OD X .156 ID

043220100

THERMOCOUPLE INSULATING SLEEVE *

045230100

PCA, RELAY CARD(KB)

04550010A

ASSY, ORIFICE HOLDER, 4 MIL

04550030A

ASSY, ORIFICE HOLDER, 10 MIL, (NOX) (KB)

046030000

AKIT, CH-43, 3 REFILLS

 

 

07271B DCN6646

39

Image 41
Contents SAN DIEGO, CA Manual AddendumFor use with the T200 Operators Manual, P/N Page About this Manual This page intentionally left blank Safety Messages Mise EN Garde Consignes DE SécuritéTable of Contents 07271B DCN6646 Do not pressurize the Sample/Span/Zero port above ambient T201 Ammonia AnalyzerTeledyne API Model T201 NH3 Analyzer Operator Manual T201 and M501 NH 3 Pneumatic Flow Outlined in the following equations Theory of OperationMinimizing PMT Drift Sample Filtration Special Considerations for Ammonia MeasurementT201 Operating Specifications T201 Analyzer SpecificationsThis page intentionally left blank Calibration Procedure Step No Action Comment Zeroing the AnalyzerSpanning the Analyzer with Nitric Oxide GAS No Conv Spanning the Analyzer with Ammonia GAS Efficiency value through the user interface, if required TNx Conv Exit NH3 Calibration Procedure NH3 Gas through the Sample Port NH3 Calibration Procedure NH3 Gas through the Span Port This page intentionally left blank Strip Chart Configurable Analog Output OverviewHyperlink + +Analog Output Pin-Outs M501 NH3 Maintenance Maintenance ScheduleDescription Replacing the Catalytic CartridgeThermocouple Location Replacing the ThermocoupleTeledyne API Model T201 NH3 Analyzer Operator Manual Flow Check Autozero Flow CheckThis page intentionally left blank Alarm Alarms and CautionsAlarms and Cautions Calculating Moly Converter Efficiencies ProcedurePurpose ToolsCalculating Moly Converter Efficiencies Moly Test Data Sheet This page intentionally left blank To our Website or contact Sales for recent updates T201 Spare Parts ListPCA,TEC DRIVER,PMT,KB Assy & TEST, Spare PS38 Teledyne API Model T201 NH3 Analyzer Operator ManualThis page intentionally left blank