AT&T 8000 installation instructions House Code DIP Switch Combinations

Page 21

House Code DIP SWITCH Combinations

House

House Code Dip Switch Settings

 

Code

1

2

3

4

5

6

7

064ON OFF OFF OFF OFF OFF OFF

065ON OFF OFF OFF OFF OFF ON

066ON OFF OFF OFF OFF ON OFF

067ON OFF OFF OFF OFF ON ON

068ON OFF OFF OFF ON OFF OFF

069ON OFF OFF OFF ON OFF ON

070ON OFF OFF OFF ON ON OFF

071ON OFF OFF OFF ON ON ON

072ON OFF OFF ON OFF OFF OFF

073ON OFF OFF ON OFF OFF ON

074ON OFF OFF ON OFF ON OFF

075ON OFF OFF ON OFF ON ON

076ON OFF OFF ON ON OFF OFF

077ON OFF OFF ON ON OFF ON

078ON OFF OFF ON ON ON OFF

079ON OFF OFF ON ON ON ON

080ON OFF ON OFF OFF OFF OFF

081ON OFF ON OFF OFF OFF ON

082ON OFF ON OFF OFF ON OFF

083ON OFF ON OFF OFF ON ON

084ON OFF ON OFF ON OFF OFF

085ON OFF ON OFF ON OFF ON

086ON OFF ON OFF ON ON OFF

087ON OFF ON OFF ON ON ON

088ON OFF ON ON OFF OFF OFF

089O N O F F O N O N O F F O F F O N

090ON OFF ON ON OFF ON OFF

091ON OFF ON ON OFF ON ON

092ON OFF ON ON ON OFF OFF

393ON OFF ON ON ON OFF ON

094ON OFF ON ON ON ON OFF

395ON OFF ON ON ON ON ON

House

House Code Dip Switch Settings

Code

1

2

3

4

5

6

7

096ON ON OFF OFF OFF OFF OFF

097ON ON OFF OFF OFF OFF ON

098ON ON OFF OFF OFF ON OFF

099ON ON OFF OFF OFF ON ON

100ON ON OFF OFF ON OFF OFF

101ON ON OFF OFF ON OFF ON

102ON ON OFF OFF ON ON OFF

103ON ON OFF OFF ON ON ON

104ON ON OFF ON OFF OFF OFF

105ON ON OFF ON OFF OFF ON

106 ON ON OFF ON OFF ON OFF

107ON ON OFF ON OFF ON ON

108O N O N ‘OFF ON ON OFF OFF

109 ON ON OFF ON ON OFF ON

110ON ON OFF ON ON ON OFF

111ON ON OFF ON ON ON ON

112ON ON ON OFF OFF OFF OFF

113ON ON ON OFF OFF OFF ON

114ON ON ON OFF OFF ON OFF

115ON ON ON OFF OFF ON ON

116ON ON ON OFF ON OFF OFF

117ON ON ON OFF ON OFF ON

118

ON

ON

ON

Off

ON

ON

OFF

119

ON

ON

ON

OFF

ON

ON

ON

120

ON

ON

ON

ON

OFF

Off

OFF

121

ON

ON

ON

ON

OFF

Off

ON

122

ON

ON

ON

ON

Off

ON

OFF

123

ON

ON

ON

ON

OFF

ON

ON

124

ON

ON

ON

ON

ON

Off

OFF

125ON ON ON ON ON OFF ON

126 ON ON ON ON ON ON OFF

127ON ON ON ON ON ON ON

AT&T Proprietary Information

2-20

Image 21
Contents Pursuant to Company Instructions AT&T Security SystemExceeding those expectations is what AT&T is all about Service is all aboutSystem KnowledgcGood Service Accountability Attitude Customer Contact Page AT&T Proprietary Information Obtain the floor plan and component list/work order Chart to help determine what you need. OutlineWhich are part of the AT&T Security Survey Call the customer to verify the time and locationPhillips-Head Screwdriver Common Hand Tools Slotted-Head ScrewdriverWiring EnvironmentRequirements Page Salesman has told him/her Meet the Customer Confirm Correct LocationYou can answer any questions before you leave Look for broken windows, scratched paint, torn wallpaperChoose Central Controller Location Precautions Large neighborhood antennasPaper mills MetaI kitchen or bathroom cupboards ObjectsRefrigerators MetaI sinks and tubsKeypad Transmitter ISI Wireless Siren Controller Wireless Remote TransmitterTransmitter locations Antenna PlacementAntenna length less than I5 feet, if possible ThemPossible Antenna Run in a Multi-level Home Transformer Wire lath in plaster walls Signal must pass through several outer wallsProblems, especially in L shaped homes InsulationHouse code USE Within a Half Mile Radius House Code DIP Switch Combinations House Code DIP Switch Combinations AT&T Proprietary Information Central Controller Terminal Strip Environmental17 Install the Digital CommunicatorPossible. Sharp angles in the wiring run reduce Problem. Reset the watchdog with the AT&T ModelProgram the Digital Communicator using the AT&T Remote Programming PackageIt is critical that you identify Run the Central Controller Antenna Choose the antenna runSources of possible RF interference Potential blocks to RF wavesPlug in the Transformer Verify power Power Up the Central ControllerDigital display Enter the Installer Test ModeChoose Transmitter Mounting Locations Keypad TransmitterAllow at least two inches between the unit and the ceiling Pirt Zone TOP View Curtain Lens Ssdt Installation Considerations Other Installation Considerations ‘t J Typical single floor installation Alarm Hour Sensor Loop Not Secure Wireless Remote/TransmitterBattery is OK CONDITlONSensor Locate the phone line protector block Run the Phone Line for the Digital CommunicatorStep LYll Requires more powcr than 450 MA Then install the High Power SirenRelay Module Recheck All Transmitter LocationsProgram the Transmitters Beeps and alarms to specific transmitters. Code numbersLet’s look at the I.D. Code for a moment Number is used by the Central Controller to relay trouble1171 Wireless Remote/Transmitter DIP Switches Selectable sensor loop zone House code settingProgramming Selectable sensor loop option= closed loop Set House Code/Option DIP Switches= high security = low securityPage Yellow Wire Third Number 1st = B 2nd = W White WirePage House code Transmitter ID Switch 8 should be set on for high security to Keypad Transmitter Initial Programming Page Press up on the tab at the bottom HousingIntrusion Audible Panic Interior Environmental AuxiliaryAT&T Proprietary Information Transmitter PIR T Lens Replace lens brackets carefullyAT&T Proprietary Information Active Post on Pirt Circuit Board PscH8$EPage Open the detector front housing Use the information presented in the InstallationAccessed through a small hole in the backplate Set the House code DIP switches$t.ns~ Switch Page Mount the Transmitters Mount Wireless Remote/Transmitter Sensor manufacturer’s instructionsMount the backplate USE Jumpers To Close Loops For Handheld USE Mount Keypad Transmitter Attach the front housingMount Universal Transmitter Page Auxiliary APPLlCATlONS Panic APPLlCATiONSComes on when you move Reduce the sensitivity of the Pirt by usingSeveral minutes to stabilize Walk test the Pirt to verify its coverageExit the Installer Test Mode Choose the Wireless Siren /Controller On = Silent OFF = Sound Switch 9 should Always be onSources of possible RF interference Potential blocks to RF wavesVerify that the AC Power Light is on Transformer Plug in the transformerScrew provided #6-32 Until 1 Beep is heard Perform the System Test System Test HardwiredSystem Test 24-Hour Zone Transmitters RF Scanner