Temperature Controls and Indicators

Temperature Controls and Indicators

Heater Power Indicators

Heater Displays

Zone A Arrow Keys

Zone B Arrow Keys

Hose Zone Arrow Keys

A

B

Heater A On/Off Key

Heater B On/Off Key

Hose Heater On/Off Key

°F

Actual Temperature Key

Temperature Scale Keys

°C

Target Temperature Key

FIG. 5. Temperature Controls and Indicators

Main Power Switch

Located on right side of unit, page 11. Turns Reactor

power ON

and OFF

. Does not turn

heater zones or pumps on.

 

Red Stop Button

Located between temperature control panel and motor

control panel, page 11. Press to shut off motor

and heater zones only. Use main power switch to shut off all power to unit.

Actual Temperature Key/LED

Press to display actual temperature.

Press and hold to display electrical current.

Target Temperature Key/LED

Press to display target temperature.

Press and hold to display heater control circuit board temperature.

313539F

13

Image 13
Contents Operation Important Safety InstructionsModels ContentsRelated Manuals Supplied ManualsElectric Shock Hazard Fire and Explosion Hazard Material Self-ignition Isocyanate ConditionsKeep Components a and B Separate Moisture Sensitivity of IsocyanatesChanging Materials Key for FIG Typical Installation, with circulationSide Supply Detail Typical Installation, without circulation Reactor H-VR Component IdentificationInside cabinet Detail of Reactor Fluid Manifold Shroud removed for clarityDetail of Pump Assembly guard removed for clarity Pump AssemblyMain Power Switch Temperature Controls and IndicatorsActual Temperature Key/LED Target Temperature Key/LEDTemperature Arrow Keys Temperature Scale Keys/LEDs Circuit BreakersTemperature Displays Heater Zone On/Off Keys/LEDsMotor ON/OFF Key/LED Motor Controls and IndicatorsPark Key/LED Pressure Key/LEDCycle Count Key/LED Spray AdjustmentsHydraulic Pressure Control Knob Motor Control Arrow KeysLocate Reactor SetupGeneral equipment guidelines Electrical requirements See table Phase Amps Watts 256886 230V 26,600 256887 400VElectrical Requirements kW/Full Load Amps Voltage SystemConnect feed pumps Install Fluid Temperature Sensor FTSConnect pressure relief lines Close gun fluid manifold valves a and B Connect heated hoseConnect whip hose to gun fluid manifold Pressure check hoseCheck hydraulic fluid level Ground systemStartup Alaf Load fluid with feed pumps Set temperatures Temperature Controls and Indicators, see Set pressure Manual current control mode onlyAvailable Pressure Imbalance Settings Change pressure imbalance setting optionalSpray SprayingOpen gun fluid manifold valves a and B Shutdown StandbyPressure Relief Procedure Circulation Through Reactor Fluid CirculationPressure RELIEF/CIRCULATION CKR Circulation Through Gun ManifoldTemperature Control Diagnostic Codes Diagnostic CodesCode Code Name Alarm Zone Code Code Name Alarm or Motor Control Diagnostic CodesFrequency of Oil Changes Ambient Recommended Temperature MaintenanceFluid Inlet Strainer Fluid Inlet Strainer ScreenRELIEF/CIRCULATION FlushingDimensions Category Data Technical DataPressure in psi MPa, bar Performance ChartsFlow Rate in lb/min kg/min Flow Rate in gal/min liter/minFlow Rate in gpm lpm Delta T in degrees F degrees C313539F Graco Information Graco Standard Warranty