Graco 313539F Temperature Scale Keys/LEDs Circuit Breakers, Heater Zone On/Off Keys/LEDs

Page 14

Temperature Controls and Indicators

Temperature Scale Keys/LEDs

Circuit Breakers

Press °F or °C to change temperature scale.

 

Heater Zone On/Off Keys/LEDs

Press to turn heater zones on and off. Also clears heater zone diagnostic codes, see page 34.

NOTE:

LEDs flash when heater zones are on. The duration of each flash shows the extent that the heater is turned on.

Temperature Arrow Keys

Press , then press or to adjust tem- perature settings in 1 degree increments.

Temperature Displays

Show actual temperature or target temperature of heater zones, depending on selected mode. Defaults to actual at startup. Range is 32-190°F (0-88°C) for A and B, 32-180°F (0-82°C) for hose.

Located inside Reactor cabinet.

Ref.

Size

Component

 

 

 

CB1

50 A

Hose/Transformer Secondary

 

 

 

CB2

40 A

Transformer Primary

 

 

 

CB3

50 A

Heater A

 

 

 

CB4

50 A

Heater B

 

 

 

CB5

20 A

Motor/Pumps

 

 

 

CB1

CB2

 

 

CB3

 

 

CB4

CB5

ti9884a

 

 

 

For wiring and cabling, see repair manual 313540.

14

313539F

Image 14
Contents Important Safety Instructions OperationContents ModelsSupplied Manuals Related ManualsElectric Shock Hazard Fire and Explosion Hazard Keep Components a and B Separate Isocyanate ConditionsMaterial Self-ignition Moisture Sensitivity of IsocyanatesChanging Materials Side Supply Detail Typical Installation, with circulationKey for FIG Typical Installation, without circulation Component Identification Reactor H-VR Detail of Reactor Fluid Manifold Shroud removed for clarity Inside cabinetPump Assembly Detail of Pump Assembly guard removed for clarityActual Temperature Key/LED Temperature Controls and IndicatorsMain Power Switch Target Temperature Key/LEDTemperature Displays Temperature Scale Keys/LEDs Circuit BreakersTemperature Arrow Keys Heater Zone On/Off Keys/LEDsPark Key/LED Motor Controls and IndicatorsMotor ON/OFF Key/LED Pressure Key/LEDHydraulic Pressure Control Knob Spray AdjustmentsCycle Count Key/LED Motor Control Arrow KeysGeneral equipment guidelines SetupLocate Reactor Electrical Requirements kW/Full Load Amps Voltage Phase Amps Watts 256886 230V 26,600 256887 400VElectrical requirements See table SystemConnect pressure relief lines Install Fluid Temperature Sensor FTSConnect feed pumps Connect whip hose to gun fluid manifold Connect heated hoseClose gun fluid manifold valves a and B Pressure check hoseGround system Check hydraulic fluid levelStartup Alaf Load fluid with feed pumps Set temperatures Temperature Controls and Indicators, see Manual current control mode only Set pressureChange pressure imbalance setting optional Available Pressure Imbalance SettingsSpraying SprayOpen gun fluid manifold valves a and B Standby ShutdownPressure Relief Procedure Pressure RELIEF/CIRCULATION Fluid CirculationCirculation Through Reactor Circulation Through Gun Manifold CKRCode Code Name Alarm Zone Diagnostic CodesTemperature Control Diagnostic Codes Motor Control Diagnostic Codes Code Code Name Alarm orMaintenance Frequency of Oil Changes Ambient Recommended TemperatureFluid Inlet Strainer Screen Fluid Inlet StrainerFlushing RELIEF/CIRCULATIONDimensions Technical Data Category DataFlow Rate in lb/min kg/min Performance ChartsPressure in psi MPa, bar Flow Rate in gal/min liter/minDelta T in degrees F degrees C Flow Rate in gpm lpm313539F Graco Standard Warranty Graco Information