Graco 313539F Change pressure imbalance setting optional, Available Pressure Imbalance Settings

Page 27

NOTE:

Check the pressure of each proportioning pump using the component A and B gauges. The pressures should be approximately equal and must remain fixed.

d. To display cycle count, press .

NOTE:

To clear counter, press and hold for 3 sec.

e. Press PSI or BAR to change pressure

scale.

5.Change pressure imbalance setting (optional)

The pressure imbalance function (status code 24, page

35)detects conditions that can cause off-ratio spray, such as loss of feed pressure/supply, pump seal failure, clogged fluid inlet filter, or a fluid leak.

NOTE:

Code 24 (pressure imbalance) is set to an alarm as the default. To change to a warning, see H-VR Repair-Parts manual 313540.

The pressure imbalance default is factory-set at 500 psi (3.5 MPa, 35 bar). For tighter ratio error detection, select a lower value. For looser detection or to avoid nuisance alarms, select a higher value.

a.

Turn main power switch OFF

.

b.

Press and hold PSI

or BAR

, then turn main

 

power switch ON

. Display will read

dP500 for psi or dP_35 for bar.

c.Press or to select desired pres- sure differential (100-999 in increments of 100 psi, or 7-70 in increments of 7 bar). See TABLE 4.

Startup

Table 4: Available Pressure Imbalance Settings

PSI

BAR

 

PSI

BAR

 

 

 

 

 

100

7

 

600

42

200

14

 

700

49

300

21

 

800

56

400

28

 

900

63

*500

*35

 

999

69

* Factory default setting.

 

d. Turn main power switch OFF

to save

changes.

 

313539F

27

Image 27
Contents Operation Important Safety InstructionsModels ContentsRelated Manuals Supplied ManualsElectric Shock Hazard Fire and Explosion Hazard Moisture Sensitivity of Isocyanates Isocyanate ConditionsMaterial Self-ignition Keep Components a and B SeparateChanging Materials Typical Installation, with circulation Key for FIGSide Supply Detail Typical Installation, without circulation Reactor H-VR Component IdentificationInside cabinet Detail of Reactor Fluid Manifold Shroud removed for clarityDetail of Pump Assembly guard removed for clarity Pump AssemblyTarget Temperature Key/LED Temperature Controls and IndicatorsMain Power Switch Actual Temperature Key/LEDHeater Zone On/Off Keys/LEDs Temperature Scale Keys/LEDs Circuit BreakersTemperature Arrow Keys Temperature DisplaysPressure Key/LED Motor Controls and IndicatorsMotor ON/OFF Key/LED Park Key/LEDMotor Control Arrow Keys Spray AdjustmentsCycle Count Key/LED Hydraulic Pressure Control KnobSetup Locate ReactorGeneral equipment guidelines System Phase Amps Watts 256886 230V 26,600 256887 400VElectrical requirements See table Electrical Requirements kW/Full Load Amps VoltageInstall Fluid Temperature Sensor FTS Connect feed pumpsConnect pressure relief lines Pressure check hose Connect heated hoseClose gun fluid manifold valves a and B Connect whip hose to gun fluid manifoldCheck hydraulic fluid level Ground systemStartup Alaf Load fluid with feed pumps Set temperatures Temperature Controls and Indicators, see Set pressure Manual current control mode onlyAvailable Pressure Imbalance Settings Change pressure imbalance setting optionalSpray SprayingOpen gun fluid manifold valves a and B Shutdown StandbyPressure Relief Procedure Fluid Circulation Circulation Through ReactorPressure RELIEF/CIRCULATION CKR Circulation Through Gun ManifoldDiagnostic Codes Temperature Control Diagnostic CodesCode Code Name Alarm Zone Code Code Name Alarm or Motor Control Diagnostic CodesFrequency of Oil Changes Ambient Recommended Temperature MaintenanceFluid Inlet Strainer Fluid Inlet Strainer ScreenRELIEF/CIRCULATION FlushingDimensions Category Data Technical DataFlow Rate in gal/min liter/min Performance ChartsPressure in psi MPa, bar Flow Rate in lb/min kg/minFlow Rate in gpm lpm Delta T in degrees F degrees C313539F Graco Information Graco Standard Warranty