Technical Data

Technical Data

Category

Data

Maximum Fluid Working Pressure

3500 psi (24.1 MPa, 241 bar)

Fluid Inlets

3/4 npsm union in 1 in. npt(f) ball valve

Fluid Outlets

Component A (ISO): #8 (1/2 in.) JIC, with #5 (5/16 in.) JIC adapter

 

Component B (RES): #10 (5/8 in.) JIC, with #6 (3/8 in.) JIC adapter

Fluid Circulation Ports

1/4 npsm(m), with plastic tubing, 250 psi (1.75 MPa, 17.5 bar) maximum

Maximum Fluid Temperature

190°F (88°C)

Maximum Output (10 weight oil at

Model H-VR: 3.0 gpm (11.4 liter/min) (60 Hz)

ambient temperature) 1:1

 

Output per Cycle

Variable: 2 oz.- 5 oz. (60 cc - 150 cc) per pump*

Stroke Length

Variable: 2 in. - 5 in. (5.08 cm - 12.7 cm)

Line Voltage Requirement

230V 3 phase units: 195-264 Vac, 50/60 Hz

 

400V 3 phase units: 338-457 Vac, 50/60 Hz

Amperage Requirement

See Models, page 2.

Heater Power

See Models, page 2.

(A and B heaters total, no hose)

 

Hydraulic reservoir capacity

3.5 gal. (13.6 liters)

Recommended hydraulic fluid

Citgo A/W Hydraulic Oil, ISO Grade 46

Sound power, per ISO 9614-2

90.9 dB(A)

Sound pressure,

84.0 dB(A)

1 m from equipment

 

Weight

955 lb (433 kg)

Wetted Parts

Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome,

 

fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically

 

resistant o-rings

*Output example: 2.5:1 ratio = 150 cc (B side):60 cc (A side)

2.5:1 output = 150 cc (B side) + 60 cc (A side) = 210 cc per cycle

All other brand names or marks are used for identification purposes and are trademarks of their respective owners.

40

313539F

Image 40
Contents Important Safety Instructions OperationContents ModelsSupplied Manuals Related ManualsElectric Shock Hazard Fire and Explosion Hazard Isocyanate Conditions Material Self-ignitionKeep Components a and B Separate Moisture Sensitivity of IsocyanatesChanging Materials Key for FIG Typical Installation, with circulationSide Supply Detail Typical Installation, without circulation Component Identification Reactor H-VRDetail of Reactor Fluid Manifold Shroud removed for clarity Inside cabinetPump Assembly Detail of Pump Assembly guard removed for clarityTemperature Controls and Indicators Main Power SwitchActual Temperature Key/LED Target Temperature Key/LEDTemperature Scale Keys/LEDs Circuit Breakers Temperature Arrow KeysTemperature Displays Heater Zone On/Off Keys/LEDsMotor Controls and Indicators Motor ON/OFF Key/LEDPark Key/LED Pressure Key/LEDSpray Adjustments Cycle Count Key/LEDHydraulic Pressure Control Knob Motor Control Arrow KeysLocate Reactor SetupGeneral equipment guidelines Phase Amps Watts 256886 230V 26,600 256887 400V Electrical requirements See tableElectrical Requirements kW/Full Load Amps Voltage SystemConnect feed pumps Install Fluid Temperature Sensor FTSConnect pressure relief lines Connect heated hose Close gun fluid manifold valves a and BConnect whip hose to gun fluid manifold Pressure check hoseGround system Check hydraulic fluid levelStartup Alaf Load fluid with feed pumps Set temperatures Temperature Controls and Indicators, see Manual current control mode only Set pressureChange pressure imbalance setting optional Available Pressure Imbalance SettingsSpraying SprayOpen gun fluid manifold valves a and B Standby ShutdownPressure Relief Procedure Circulation Through Reactor Fluid CirculationPressure RELIEF/CIRCULATION Circulation Through Gun Manifold CKRTemperature Control Diagnostic Codes Diagnostic CodesCode Code Name Alarm Zone Motor Control Diagnostic Codes Code Code Name Alarm orMaintenance Frequency of Oil Changes Ambient Recommended TemperatureFluid Inlet Strainer Screen Fluid Inlet StrainerFlushing RELIEF/CIRCULATIONDimensions Technical Data Category DataPerformance Charts Pressure in psi MPa, barFlow Rate in lb/min kg/min Flow Rate in gal/min liter/minDelta T in degrees F degrees C Flow Rate in gpm lpm313539F Graco Standard Warranty Graco Information