Graco 313539F important safety instructions Fire and Explosion Hazard

Page 5

Warnings

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

• Use equipment only in well ventilated area.

• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

• Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

Ground all equipment in the work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

PRESSURIZED ALUMINUM PARTS HAZARD

Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in pressurized aluminum equipment. Such use can cause serious chemical reaction and equipment rupture, and result in death, serious injury, and property damage.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.

Do not leave the work area while equipment is energized or under pressure. Turn off all equipment and follow the Pressure Relief Procedure in this manual when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu- facturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

 

 

MOVING PARTS HAZARD

 

 

Moving parts can pinch or amputate fingers and other body parts.

OR

• Keep clear of moving parts.

 

 

• Do not operate equipment with protective guards or covers removed.

 

 

• Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,

 

 

follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.

 

 

 

 

 

BURN HAZARD

 

 

Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe

 

 

burns:

 

 

• Do not touch hot fluid or equipment.

 

 

• Wait until equipment/fluid has cooled completely.

313539F

5

Image 5
Contents Operation Important Safety InstructionsModels ContentsRelated Manuals Supplied ManualsElectric Shock Hazard Fire and Explosion Hazard Material Self-ignition Isocyanate ConditionsKeep Components a and B Separate Moisture Sensitivity of IsocyanatesChanging Materials Side Supply Detail Typical Installation, with circulationKey for FIG Typical Installation, without circulation Reactor H-VR Component IdentificationInside cabinet Detail of Reactor Fluid Manifold Shroud removed for clarityDetail of Pump Assembly guard removed for clarity Pump AssemblyMain Power Switch Temperature Controls and IndicatorsActual Temperature Key/LED Target Temperature Key/LEDTemperature Arrow Keys Temperature Scale Keys/LEDs Circuit BreakersTemperature Displays Heater Zone On/Off Keys/LEDsMotor ON/OFF Key/LED Motor Controls and IndicatorsPark Key/LED Pressure Key/LEDCycle Count Key/LED Spray AdjustmentsHydraulic Pressure Control Knob Motor Control Arrow KeysGeneral equipment guidelines SetupLocate Reactor Electrical requirements See table Phase Amps Watts 256886 230V 26,600 256887 400VElectrical Requirements kW/Full Load Amps Voltage SystemConnect pressure relief lines Install Fluid Temperature Sensor FTSConnect feed pumps Close gun fluid manifold valves a and B Connect heated hoseConnect whip hose to gun fluid manifold Pressure check hoseCheck hydraulic fluid level Ground systemStartup Alaf Load fluid with feed pumps Set temperatures Temperature Controls and Indicators, see Set pressure Manual current control mode onlyAvailable Pressure Imbalance Settings Change pressure imbalance setting optionalSpray SprayingOpen gun fluid manifold valves a and B Shutdown StandbyPressure Relief Procedure Pressure RELIEF/CIRCULATION Fluid CirculationCirculation Through Reactor CKR Circulation Through Gun ManifoldCode Code Name Alarm Zone Diagnostic CodesTemperature Control Diagnostic Codes Code Code Name Alarm or Motor Control Diagnostic CodesFrequency of Oil Changes Ambient Recommended Temperature MaintenanceFluid Inlet Strainer Fluid Inlet Strainer ScreenRELIEF/CIRCULATION FlushingDimensions Category Data Technical DataPressure in psi MPa, bar Performance ChartsFlow Rate in lb/min kg/min Flow Rate in gal/min liter/minFlow Rate in gpm lpm Delta T in degrees F degrees C313539F Graco Information Graco Standard Warranty