7. Pick-up fails.
Cause | Step | Checks | YES/NO | Remedies |
|
|
|
|
|
| 1 | Move the copyboard to the left | YES | See |
|
| until it stops, and open the top |
| “Troubleshooting Feeding |
|
| cover. Does the |
| Faults.” |
|
| rotate when the door switch is |
|
|
|
| turned ON and the Copy Start |
|
|
|
| key is pressed at the correct |
|
|
|
|
|
| |
Main motor (M1) | 2 | Is the main motor rotating? | NO | See “The main motor fails |
|
|
|
| to rotate.” |
|
|
|
|
|
3 | Does the copier operate nor- | YES | Check the sensor lever. | |
|
| mally when the |
|
|
|
| (Q131) is blocked with paper? |
|
|
|
|
|
|
|
4 | Set the meter to the ‘30VDC’ | YES | Check the spring clutch in | |
PC420/430/FC220), |
| range. Does the voltage |
| the registration assembly |
Registration solenoid |
| between |
| and |
(SL1; PC400/FC200) |
|
| normal, replace the | |
|
| power supply PCB change to |
| solenoid. |
|
| about 24 V at |
|
|
DC controller/ |
| NO | Check the wiring from the | |
|
| |||
DC power supply PCB |
|
|
| solenoid to the DC con- |
|
|
|
| troller/DC power supply |
|
|
|
| PCB; if normal, replace |
|
|
|
| the DC controller/DC |
|
|
|
| power supply PCB. |
|
|
|
|
|
8. The scanning lamp fails to go ON.
Cause | Step | Checks | YES/NO | Remedies |
|
|
|
|
|
Scanning lamp | 1 | Is the scanning lamp unit | NO | |
| attached correctly? |
|
| |
|
|
|
|
|
Scanning lamp | 2 | Is the scanning lamp black? | YES | Replace the scanning |
|
|
| lamp unit. | |
|
|
|
|
|
DC controller/DC | 3 | Is the connector of the scanning | YES | Replace the DC controller/ |
power supply PCB |
| lamp connected firmly? |
| DC power supply PCB. |
|
|
|
|
|
Connector |
|