CHAPTER 4 TROUBLESHOOTING MALFUNCTIONS
9. The main motor fails to rotate.
Cause | Step | Checks | YES/NO | Remedies |
|
|
|
|
|
Main motor (M1) | 1 | Set the meter to the ‘30VDC’ | YES | Replace the main motor. |
|
| range. Does the voltage |
|
|
DC controller/DC |
| NO | Check the wiring from the | |
| between | |||
power supply PCB |
|
| motor to the DC controller/ | |
| change from about 0 V to about |
| ||
|
|
| DC power supply PCB; if | |
|
| 20 V according to the operation |
| |
|
|
| normal, replace the DC | |
|
| of the main motor? |
| |
|
|
| controller/DC power | |
|
|
|
| |
|
|
|
| supply PCB. |
|
|
|
|
|
10. The copyboard fails to move.
Cause | Step | Checks | YES/NO | Remedies |
|
|
|
|
|
Main motor (M1) | 1 | Is the main motor rotating? | NO | See “The main motor fails |
|
|
|
| to rotate.” |
|
|
|
|
|
Copyboard, | 2 | Push the copyboard by hand. | NO | Check the copyboard and |
Copyboard drive |
| Does it move smoothly? |
| copyboard drive assembly. |
assembly |
|
|
|
|
|
|
|
|
|
DC controller/DC | 3 | Set the meter to the ‘200Ω’ | YES | Check the wiring from the |
power supply PCB |
| range. Disconnect J902 from |
| solenoid to the DC con- |
|
| the copyboard drive solenoid, |
| troller/DC power supply |
|
| and measure the resistance |
| PCB; if normal, replace |
|
| between terminals of SL2. |
| the DC controller/DC |
|
| Is it about 120Ω? |
| power supply PCB. |
|
|
|
|
|
Copyboard drive |
|
| NO | Check the solenoid (SL2). |
solenoid (SL2) |
|
|
|
|
|
|
|
|
|