Pelco 9770 HOW to Install or Replace a CM9700-SER Card in the CC1, ISA Slot Number W1 IRQ Setting

Page 46

HOW TO INSTALL OR REPLACE A CM9700-SER CARD IN THE CC1

If you have ordered a replacement or additional CM9700-SER serial communication card, complete the following steps to configure the jumpers on the CC1 board for the slot position the new SER card will occupy.

NOTE: When connecting peripheral equipment to the serial communication ports, shielded cabling is required to comply with CE emissions guidelines.

1. Turn off the CC1 power switch.

WARNING: Failure to turn off the CC1 power switch could result in serious damage to the equipment.

2.Remove the top cover of the CC1. Refer to Figure 36.

a.Remove the 10 screws that hold the top cover in place.

b.Tilt the top cover up at a slight angle, as indicated by the dotted line in the drawing, and then pull the cover backwards to remove the cover from the front edge of the CC1 chassis.

Figure 36. Removing the CC1 Top Cover

3. Set the W1 interrupt (IRQ) and W2 address select jumpers on the SER card. Refer to Figure 37.

Note that the jumper settings vary, depending on the ISA slot in which the SER card is to be installed. Refer to the following tables for a list of SER card jumper assignments.

Table F. SER Card Jumper Assignments for a CM9700-CC1 System Control

ISA Slot Number

W1 IRQ Setting

W2 Address Setting

 

 

 

1

IRQ 10

Pins 1 to 2 and 3 to 4

 

 

 

2

IRQ 11

Pins 1 to 2 only

 

 

 

3

IRQ 12

Pins 3 to 4 only

 

 

 

4

IRQ 5

No jumpers

 

 

 

Table G. SER Card Jumper Assignments for a CM9700-NW1 Network Interface Unit

ISA Slot Number

W1 IRQ Setting

W2 Address Setting

 

 

 

1

IRQ 10

Pins 1 to 2 and 3 to 4

 

 

 

2

IRQ 11

Pins 1 to 2 only

 

 

 

3

IRQ 12

Pins 3 to 4 only

 

 

 

NOTE: For a CM9700-NW1, the default configuration is one SER card. A maximum of three SER cards can be installed in a CM9700-NW1.

46

C1555M-G (12/07)

Image 46
Contents System C1555M-G 12/07 Contents List of Illustrations List of Tables Description Matrix Bay ModelsController and CPU Components Network Interface UnitOptional Components KeyboardsCompatible Receivers CM9700-CC1 InstallationUnpacking CM9770-MXBMounting CM9770-MXB Mounting BaffleMounting the CM9770-MXB on Top of the Mounting Baffle Mounting the CM9700-CC1 Video INPUT/OUTPUT Connections Opening the CM9770-MXB Front CoverInsert or Replace a Video Card Installing Video Input Cards CM9770-VCCHow to Turn On the Pelco V-Sync Signal Remove a Video CardInsert or Replace a Monitor Card Installing Monitor Output Cards CM9770-VMCRemove a Monitor Card Performing a Basic LED Check Color Diagnostic CheckTable A. LEDs Illuminated During a Basic Check Insert or Replace a Rear Panel Video BNC Card CM9770-RPC Installing Rear Panel BNC CardsRemove a Rear Panel Video BNC Card CM9770-RPC CM9770-RPC Termination Jumpers-Right Card Looping Video Looping Video Out from the CM9770-MXBInsert or Replace a Rear Panel Monitor BNC Card CM9770-RPM Video INPUT/OUTPUT Capacity Single BayMultiple Bays, Single Node Sample Sideframing System Using an Output Bay Sample Single-Node System with Downframing Networked System Sample Networked SystemInstall a Backup Power Supply Power Supply Module CM9700-MPSRemove a Backup Power Supply HOW to Replace the Fuse in a Power Supply Module How to Replace a Power Supply FuseHOW to Turn OFF the Audible Power Supply Alarm Power Supply Alarm Speaker SwitchSystem Device Connections CM9700-CC1 Device ConnectionsCM9700-MGR PC Pin-Out Detail As necessary NIU connection RS-422 COM Port Sercom ConnectionsNot have to be in sequential ports Switch NIU connection Table D. Data Connections-Single Node, Hot-Switched SystemSwitch MXB connectionsSample CM9770-MXB to CM9700-CC1 Connection System Start-Up Initialize the CC1Verify System Operation Initialize KeyboardsDisplay the CM9770-MXB Software Version Level Monitor Color AdjustmentDisplay a Blue Raster Screen Programming Your System Getting Help Using CM9700-MGR Sample WizardOperation Operating Your SystemAppendix HOW to Expand Your SystemSystem Architecture Sideframing Downframing Downframing with DFC Cards Downframe Cards DFC Card HOW to Install or Replace a CM9700-SER Card in the CC1 ISA Slot Number W1 IRQ SettingHow to Install a CM9700-SER Card When LED Is On Video Input Card CM9770-VCC DetailColor When LED is on or blinking Monitor Output Card CM9770-VMC DetailPort 1 RS-422 Baud Rate Test ModeColor System Data ProtectionNetworking Connecting Satellite Devices Programming Satellite DevicesHOW to Install Video Patch Panels CM9700-VPP CM9700-VPP Vertical MountMounting the CM9770-MXB in AN Open Rack Mounting the CM9770-MXB in an Open RackAUTOEXEC.BAT and the Boot Process DOS Environment and Command ReferenceBoot Process Invoking the CM9700 ExecutableNavigating the DOS Directory Tree DOS CommandsFile Names and DOS Example PATH=c\c\dosc\windowsExample Using the Wild Card CharacterManipulating Files in the DOS Environment Change to the 9700 directoryDOS Reference \CDBackslash \ symbol Help commandFloppy of a disk formatted using this switch By default, DOS searchers just the current directorySymptom Possible Cause Corrective Action TroubleshootingProblems with the CC1 VCC Card CF LED Is Illuminated and the AUX LED Is BlinkingSwitch Monitor Display ProblemsLED Indicators on the Power Supply Module Front Panel Label ColorSpecifications Input Voltage Differential Gain 51% Differential Phase DegreesSignal to Noise Ratio 71dBrms CommunicationRegulatory Notices CM9780-MXBProduct Warranty and Return Information ISO9001