JAI M7+ CL, CV-M4+ External Trigger Modes, Accumulation latency time for H a-synchronous trigger

Page 16

CV-M4+/M4+CL, CV-M7+/M7+CL

6.4. External Trigger Modes

This camera has 3 external asynchronous trigger modes, which can be set by RS-232C commands or switches.

1.

Edge Pre-select Mode. TR=1

Pre-selected exposure. (SM=0, SM=1)

2.

Pulse Width Control Mode. TR=2

Pulse width controlled exposure.

3.Frame Delay read out mode. TR=3 Pre-select exp. Read out by trailing trig. edge.

The trigger can be H synchronous (HC=0) or H a-synchronous (HC=1). Refer to fig. 12.

In H synchronous mode, the accumulation will start at the first H (LEN) after the trigger leading edge. In H a-synchronous mode the trigger leading edge will immediately reset the internal H, (LEN). After a Xsub pulse the accumulation will start. Shown in fig. 19.

In edge pre-select mode the shutter time can be selected from the normal 10 fixed steps. (SM=0). Or it can be selected from the 1056 steps programmable (SM=1).

Remark that H is 39.3 sec. But 43.3 sec. when vertical binnig is on.

Restart Continuous Trigger RCT mode (RC=1) can be activated in edge pre-select mode (TR=1). (By RS-232C and CL only)

In pulse width control (PWC) mode the exposure time can be from 2H to . Thermal noise and dark current noise will increase by accumulation time, therefore the exposure time is not recommended to exceed 2 seconds.

Vertical binnig mode (BI=1) can be used in all 3 modes. Only with full scan. (SC=0). Binning will only work on M4+ and M4CL+.

Partial scan (SC=0 through 3) can be used in all 3 modes. Only with binning off. (BI=0).

For all 3 modes smearless read out (SL=1) can be used. At the leading edge of the trigger pulse a dump read out of the vertical ccd register is performed before the accumulation is started. It takes 133 H. It means that the trigger pulse width in PWC and frame delay mode should be >133H. (5.23 msec.)

For frame delay read out (TR=3) the multiple shutter function is available. (ML=1). It can also be combined with smearless read out.

Trigger

Int. HD

Xsub

Accum

3 clk

157 clk

 

3.88s

Fig. 19. Accumulation latency time for H a-synchronous trigger.

- 15 -

Image 16
Contents CV-M4+/M4+CL CV-M7+/M7+CL CV-M4+/M4+CL, CV-M7+/M7+CL General Main FeaturesStandard Composition Locations and Functions LocationsDigital Output Connector for EIA-644 Lvds Pin Multi-connector DC-IN/RS232CPin Assignment Video signal, LEN, FEN Digital Output Connector for Camera LinkDval and EEN Input and Output Circuits Video outputTrigger input Multi Shutter input Composite Sync outputCamera Link interface MUXFunctions and Operations CV-M4+Block DiagramBasic functions Binning Color versions CV-M7+and CV-M7+CL Color coding from a Primary RGB CCD Bayer filterOutput of Timing Signals Restart Continuous Trigger mode. RCT Continuous Operation Non triggered Polarity and other functionsVertical timing details, full frame Vertical timing details with 1/2 partial scanning External Trigger Modes Accumulation latency time for H a-synchronous triggerEdge Pre-select Mode Important notes on using this modeEdge Pre-select, smearless Pulse Width Control Mode Pulse WidthFrame-delay read out Mode Frame DelayFrame-delay read out Mode with multiple exposure Multiple exposure, normal and smearlessOther Functions Gain and set-upConfiguring the Camera Mode setting SW1 on rearMode setting SW301 inside Internal Switch and Jumper SettingsRS-232C control CV-M4+command list Timing and shutter related commandsCamera Control Tool for CV-M4+ Specifications External Appearance and DimensionsSpectral sensitivity Specification table SpecificationsTypical CCD Characteristics PrecautionsAppendix Camera Link Test points Camera Link test pointsUsers Mode Settings Users Modifications Users Record