JAI CV-M7+, M7+ CL, CV-M4+, M4+ CL operation manual Other Functions, Gain and set-up

Page 22

CV-M4+/M4+CL, CV-M7+/M7+CL

6.9. Other Functions.

Functions which can be controlled by either RS-232C or switches, or both.

Gain and set-up.

!! Do not adjust these settings unless you have knowledge to video adjustments!!

The video gain is set to manual. In manual gain mode, either the gain level (GA) or the rear potentiometer (RP). can adjust the level.

Set-up level. (SU). This setting can adjust the set-up level (or black level).

Vertical Binning (BI). Only vertical binning is possible. It can be selected by the command BI=1, or by the internal switch SW301-6. (Off 0 normal, ON = V-binnig.)

Binning is only for CV-M4+ and M4+CL.

When binning is active, the horizontal time H is changed from 39.3 sec. to 43.3 sec. It will result in longer exposure times in Edge Pre-Select shutter mode PE.

SYNC/EEN output. (SE). Will select SYNC or EEN signal output on pin #9 on 12-pin connector.

Trigger polarity. (TP). Will invert the trigger-input signal.

LEN/FEN/EEN polarity. (FP). Will invert the LEN, FEN and EEN output signal.

Important notes on using this functions.

Do not attempt to adjust the set-up level without knowledge to it.

Do not attempt to use ASCII commands not shown in “7.5. CV-M4+command list.”

- 21 -

Image 22
Contents CV-M4+/M4+CL CV-M7+/M7+CL CV-M4+/M4+CL, CV-M7+/M7+CL General Main FeaturesStandard Composition Locations and Functions LocationsDigital Output Connector for EIA-644 Lvds Pin Multi-connector DC-IN/RS232CPin Assignment Video signal, LEN, FEN Digital Output Connector for Camera LinkDval and EEN Trigger input Multi Shutter input Input and Output CircuitsVideo output Composite Sync outputCamera Link interface MUXFunctions and Operations CV-M4+Block DiagramBasic functions Binning Color versions CV-M7+and CV-M7+CL Color coding from a Primary RGB CCD Bayer filterOutput of Timing Signals Restart Continuous Trigger mode. RCTContinuous Operation Non triggered Polarity and other functionsVertical timing details, full frame Vertical timing details with 1/2 partial scanning External Trigger Modes Accumulation latency time for H a-synchronous triggerEdge Pre-select Mode Important notes on using this modeEdge Pre-select, smearless Pulse Width Control Mode Pulse WidthFrame-delay read out Mode Frame DelayFrame-delay read out Mode with multiple exposure Multiple exposure, normal and smearlessOther Functions Gain and set-upMode setting SW301 inside Configuring the CameraMode setting SW1 on rear Internal Switch and Jumper SettingsRS-232C control CV-M4+command list Timing and shutter related commandsCamera Control Tool for CV-M4+ Specifications External Appearance and DimensionsSpectral sensitivity Specification table SpecificationsTypical CCD Characteristics PrecautionsAppendix Camera Link Test points Camera Link test pointsUsers Mode Settings Users Modifications Users Record