JAI CV-M4+, M7+ CL, CV-M7+, M4+ CL Edge Pre-select Mode, Important notes on using this mode

Page 17

CV-M4+/M4+CL, CV-M7+/M7+CL

6.5. Edge Pre-select Mode

The trigger leading edge will start the exposure H synchronous or H a-synchronous (HC=0, HC=1). The exposure stops and is read out after the shutter time selected. It can be the 10 steps in normal or 1056 steps in programmable. SM=0 or SM=1. This mode will operate with full and partial scanning and with V-binning (M4+ and M4CL+ only). Partial scanning and binning in combinations is not allowed.

In this mode the Restart Continuous Trigger mode (RC=1) can be activated. (By RS-232C and CL only). The camera is then running continuously, and it can be reset and restarted by the trigger pulse.

If smearless read out (SL=1) is used, the exposure starts with a delay 133H (5.23 msec.) after the trigger. An EEN pulse will indicate the active accumulation time, and a FEN pulse indicates that the resulting video is read out.

To use this mode:

 

 

Set function:

Trigger mode “Edge Pre-select”

TR = 1

 

Shutter mode “Normal” or “Programmable”

SM=0, SM=1

 

“Shutter Speed”

SH=0 through 9

 

“Programmable exposure”

PE=0 through 1057

 

“H synchronous trigger”

HC=0, HC=1

 

“Restart Continuous Trigger”

RC=0, RC=1

 

“Smearless readout”

SL=0, SL=1

 

Polarity and other functions

 

Input:

Ext. trigger to LVDS/Camera Link or pin 10 on 12-pin connector.

Important notes on using this mode.

The duration of the trigger should be >2H to <3V. (>72.64sec to <120msec).

The minimum trigger interval should be >(exposure time + 1 frame). A new trigger must not be applied during the previous frame read out. (Before FEN is high).

Smearless readout cannot be used together with Reset Continuous Trigger.

Fig. 20. Edge Pre-select

- 16 -

Image 17
Contents CV-M4+/M4+CL CV-M7+/M7+CL CV-M4+/M4+CL, CV-M7+/M7+CL Standard Composition Main FeaturesGeneral Locations Locations and FunctionsPin Assignment Pin Multi-connector DC-IN/RS232CDigital Output Connector for EIA-644 Lvds Dval and EEN Digital Output Connector for Camera LinkVideo signal, LEN, FEN Video output Input and Output CircuitsTrigger input Multi Shutter input Composite Sync outputMUX Camera Link interfaceBasic functions CV-M4+Block DiagramFunctions and Operations Binning Color coding from a Primary RGB CCD Bayer filter Color versions CV-M7+and CV-M7+CLRestart Continuous Trigger mode. RCT Output of Timing SignalsPolarity and other functions Continuous Operation Non triggeredVertical timing details, full frame Vertical timing details with 1/2 partial scanning Accumulation latency time for H a-synchronous trigger External Trigger ModesImportant notes on using this mode Edge Pre-select ModeEdge Pre-select, smearless Pulse Width Pulse Width Control ModeFrame Delay Frame-delay read out ModeMultiple exposure, normal and smearless Frame-delay read out Mode with multiple exposureGain and set-up Other FunctionsMode setting SW1 on rear Configuring the CameraMode setting SW301 inside Internal Switch and Jumper SettingsRS-232C control Timing and shutter related commands CV-M4+command listCamera Control Tool for CV-M4+ Spectral sensitivity External Appearance and DimensionsSpecifications Specifications Specification tableAppendix PrecautionsTypical CCD Characteristics Camera Link test points Camera Link Test pointsUsers Record Users Mode Settings Users Modifications