JAI M4+ CL, M7+ CL Configuring the Camera, Mode setting SW1 on rear, Mode setting SW301 inside

Page 23

CV-M4+/M4+CL, CV-M7+/M7+CL

7. Configuring the Camera

7.1. Mode setting SW1 on rear

SHUTTER

EXT.

TRIGGER

SCANNING

SMEAR-LESS CONTROL

Rear SW

OFF

ON

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

9

10

1/24

1/50

1/100

1/200

1/400

1/800

1/1500

1/3000

1/5000

1/10,000

seconds

<

<

<

<

<

<

<

<

>

>

 

<

<

<

<

>

>

>

>

<

<

 

<

<

>

>

<

<

>

>

<

<

 

<

>

<

>

<

>

<

>

<

>

Frame delay

<

>

<

>

 

Off

Edge presel.

Pulse width

<

<

>

>

 

 

 

part.1/2

part.1/4

part.1/8

 

<

<

>

>

 

Full

 

 

 

 

 

 

 

 

 

<

>

<

>

 

 

 

 

 

 

 

Normal < > Smear-less

 

 

Local

 

<

>

RS232C

 

 

 

Fig. 25. SW1 on camera rear

7.2. Mode setting SW301 inside

Switch shown with factory settings. SW 6 Binning, for M4+/M4+CL only.

Internal SW

 

 

 

-

Low active

Internal SW

 

 

 

OFF

ON

 

 

 

+

High active

 

OFF

ON

 

 

 

TRIGGER sel

1

LVDS

<

> Hirose

 

TRIGGER sel

1

LVDS

<

> Hirose

TRIGGER pol

2

+

<

>

-

 

TRIGGER pol

2

+

<

>

-

LEN/FEN/EEN pol

3

+

<

>

-

LEN/FEN/EEN pol

3

+

<

>

-

MULTIPLE EXP.

4

Off

<

>

On

 

MULTIPLE EXP.

4

Off

 

<

> On

NC

5

Off

<

>

Ver

 

NC

5

 

 

 

 

BINNING

6

 

BINNING

6

Off

<

>

Ver

NC

7

 

 

 

 

 

NC

7

 

 

 

 

NC

8

 

 

 

 

 

NC

8

 

 

 

 

M4+/M7+

Shown in factory settings

M4+CL/M7+CL

 

Fig. 26. Internal Switch

7.3. Internal Switch and Jumper Settings

The jumper JP301 for serial communication is placed on PK8372A. Short = via Camera Link. Open = RS-232C via the 12 pin Hirose connector.

SW301

1 8

JP301

Fig. 27. Internal switch and jumper setting

- 22 -

Image 23
Contents CV-M4+/M4+CL CV-M7+/M7+CL CV-M4+/M4+CL, CV-M7+/M7+CL Standard Composition Main FeaturesGeneral Locations Locations and FunctionsPin Assignment Pin Multi-connector DC-IN/RS232CDigital Output Connector for EIA-644 Lvds Dval and EEN Digital Output Connector for Camera LinkVideo signal, LEN, FEN Composite Sync output Input and Output CircuitsVideo output Trigger input Multi Shutter inputMUX Camera Link interfaceBasic functions CV-M4+Block DiagramFunctions and Operations Binning Color coding from a Primary RGB CCD Bayer filter Color versions CV-M7+and CV-M7+CLRestart Continuous Trigger mode. RCT Output of Timing SignalsPolarity and other functions Continuous Operation Non triggeredVertical timing details, full frame Vertical timing details with 1/2 partial scanning Accumulation latency time for H a-synchronous trigger External Trigger ModesImportant notes on using this mode Edge Pre-select ModeEdge Pre-select, smearless Pulse Width Pulse Width Control ModeFrame Delay Frame-delay read out ModeMultiple exposure, normal and smearless Frame-delay read out Mode with multiple exposureGain and set-up Other FunctionsInternal Switch and Jumper Settings Configuring the CameraMode setting SW1 on rear Mode setting SW301 insideRS-232C control Timing and shutter related commands CV-M4+command listCamera Control Tool for CV-M4+ Spectral sensitivity External Appearance and DimensionsSpecifications Specifications Specification tableAppendix PrecautionsTypical CCD Characteristics Camera Link test points Camera Link Test pointsUsers Record Users Mode Settings Users Modifications