JAI M7+ CL, CV-M7+, M4+ CL CV-M4+command list, Timing and shutter related commands

Page 25

CV-M4+/M4+CL, CV-M7+/M7+CL

7.5. CV-M4+command list

 

 

 

Command Name

Format

 

Parameter

 

 

Remarks

 

 

A

General settings and

useful commands

 

 

 

 

EB

 

 

Echo Back

EB=[Param.]<CR><LF>

0=Echo off

1=Echo on

 

Off at power up

ST

 

 

Camera Status request

ST?<CR><LF>

 

 

 

Actual setting

HP

 

 

Online Help request

HP?<CR><LF>

 

 

 

Command list

VN

 

 

Firmware version

VN?<CR><LF>

 

 

 

3 letter version

 

B – Timing and shutter related commands

 

 

 

 

SC

 

 

Scanning format

SC=[Param.]<CR><LF>

0=full frame

1=1/2 partial

 

*1)

 

 

 

 

 

 

 

2=1/4 partial

3=1/8 partial

 

 

TR

 

 

Trigger mode

TR=[Param.]<CR><LF>

0=normal

1=Edge

 

 

 

 

 

 

 

 

 

2=Pulse width

3=Frame delay

 

 

HC

 

 

H synchronous accum

HC=[Param.]<CR><LF>

0=H synchr

1= H a-synchr

 

 

SM

 

 

Shutter mode

SM=[Param.]<CR><LF>

0=Normal

1=Programmab.

 

 

SH

 

 

Shutter speed

SH=[Param.]<CR><LF>

0=Off (1/24)

1=1/50

 

All10 steps are

 

 

 

 

 

 

 

2=1/100

3=1/200

 

valid in normal

 

 

 

 

 

 

 

4=1/400

5=1/800

 

trigger mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6=1/1500

7=1/3000

 

 

 

 

 

 

 

 

 

8=1/5500

9=1/10,000

 

 

PE

 

 

Programmable expos.

PE= Param. <CR><LF>

0=2.5 H, 1=3.5H

1055=1057.5 H

 

 

 

 

 

 

 

[

]

 

 

 

H= 39.3 sec

 

 

 

 

 

 

 

 

 

 

Bin. H= 43.3 sec.

BI

 

 

Binning

BI=[Param.]<CR><LF>

0=off

1=vertical

 

*1). Only for SC=0.

 

 

 

 

 

 

 

 

 

 

M4+ and M4+CL

SL

 

 

Smearless

SL=[Param.]<CR><LF>

0=Off

1=ON

 

TR=1, 2 or 3

RC

 

 

Reset Continuous Trig

RC=[Param.]<CR><LF>

0=Off

1=ON

 

Only for TR=1

 

C – Signals and polarity

 

 

 

 

 

 

SO

 

 

Sync on video

SO=[Param.]<CR><LF>

0=no sync on v.

1=sync on v.

 

Pin #4 on 12 pin

ML

 

 

MuLtiple shutter

ML=[Param.]<CR><LF>

0=OFF

1=On

 

Multi Trig input

 

 

 

 

 

 

 

 

 

 

TR=3

SE

 

 

Sync/EEN

SE=[Param.]<CR><LF>

0= Sync out

1=EEN out

 

Pin #9 on 12 pin

FP

 

 

FEN/LEN/EEN polarity

FP=[Param.]<CR><LF>

0= active low

1= active high

 

 

TP

 

 

Trigger polarity

TP=[Param.]<CR><LF>

0= active low

1= active high

 

*2)

TI

 

 

Trigger Input

TI=[Param.]<CR><LF>

0= Hirose 12p

1= LVDS (CL)

 

 

 

D – Gain and analogue signals setting

 

 

 

 

 

GA

 

 

Manual gain Level

GA=[Param.]<CR><LF>

0=low

510=high

 

Range 0 to 510

RP

 

 

Rear Potentiometer

RP=[Param.]<CR><LF>

0=manual gain

1=rear potm.

 

 

SU

 

 

Setup Level

SU=[Param.]<CR><LF>

0=low

255=high

 

Range 0 to 255

 

E – Saving and loading data in EEPROM

 

 

 

 

LD

 

 

Load settings from

LD=[Param.]<CR><LF>

0=Factory data

1=User 1 area

 

Latest used data

 

 

 

camera EEPROM

 

 

2=User 2 area

3=User 3 area

 

area becomes

 

 

 

 

 

 

 

 

 

 

default at next

 

 

 

 

 

 

 

 

 

 

power up

SA

 

 

Save settings to

SA=[Param.]<CR><LF>

1=User 1 area

2=User 2 area

 

Parameter = 0 is

 

 

 

camera EEPROM

 

 

3=User 3 area

 

 

not allowed

EA

 

 

EEPROM area request

EA?<CR><LF>

0=Factory data

1=User 1 area

 

Return the used

 

 

 

 

 

 

 

3=User 3 area

3=User 3 area

 

data from area

 

 

 

 

 

 

 

 

 

 

*3)

*1) Binning can also be selected by the internal switch SW301.6. Binning has priority over partial scanning. If partial scanning is active when a binning mode is activated, binning will take over and the scanning will be full. The line frequency will be lower in V binning modes (H= 43.3 sec.).

*2) If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.

*3) Data from the latest used data area is loaded as default on power up.

!!Do not try to use commands not shown in the list.

-24 -

Image 25
Contents CV-M4+/M4+CL CV-M7+/M7+CL CV-M4+/M4+CL, CV-M7+/M7+CL General Main FeaturesStandard Composition Locations Locations and FunctionsDigital Output Connector for EIA-644 Lvds Pin Multi-connector DC-IN/RS232CPin Assignment Video signal, LEN, FEN Digital Output Connector for Camera LinkDval and EEN Video output Input and Output CircuitsTrigger input Multi Shutter input Composite Sync outputMUX Camera Link interfaceFunctions and Operations CV-M4+Block DiagramBasic functions Binning Color coding from a Primary RGB CCD Bayer filter Color versions CV-M7+and CV-M7+CLRestart Continuous Trigger mode. RCT Output of Timing SignalsPolarity and other functions Continuous Operation Non triggeredVertical timing details, full frame Vertical timing details with 1/2 partial scanning Accumulation latency time for H a-synchronous trigger External Trigger ModesImportant notes on using this mode Edge Pre-select ModeEdge Pre-select, smearless Pulse Width Pulse Width Control ModeFrame Delay Frame-delay read out ModeMultiple exposure, normal and smearless Frame-delay read out Mode with multiple exposureGain and set-up Other FunctionsMode setting SW1 on rear Configuring the CameraMode setting SW301 inside Internal Switch and Jumper SettingsRS-232C control Timing and shutter related commands CV-M4+command listCamera Control Tool for CV-M4+ Specifications External Appearance and DimensionsSpectral sensitivity Specifications Specification tableTypical CCD Characteristics PrecautionsAppendix Camera Link test points Camera Link Test pointsUsers Record Users Mode Settings Users Modifications