JAI M7+ CL, CV-M7+, M4+ CL Functions and Operations, CV-M4+Block Diagram, Basic functions

Page 9

CV-M4+/M4+CL, CV-M7+/M7+CL

5.5. CV-M4+Block Diagram

Fig. 9. Block diagram for the camera

6. Functions and Operations

6.1. Basic functions

The CCD scanning format can be selected between full or partial scanning. With partial scanning only the vertical central part of the CCD sensor is read out with a higher frame rate. The partial scan is done by a fast dump read out of the lines in the vertical ccd register down to the top of the partial image. The partial part of the image is read out with normal speed. The lines below the partial image is read out and dumped with a high speed. With partial scan the shutter speed is limited to be shorter than the frame read out time. (SC=1 1/50. SC=2 1/100. SC=3 1/200). In PWC mode TR=2, there is no limitation.

A minor signal distortion can be expected below highlighted areas, (saturated areas). It is caused by limitation in the vertical ccd register transfer efficiency at high speed.

Lines shown in partial scans are: 1/2 PS 512 lines. 1/4 PS 256 lines. 1/8 PS 128 lines.

Imaged scene

 

 

 

1380 pixels

 

1/2 PS, 512 pixels

1/4 PS, 256 pixels 1/8 PS, 128 pixels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Partial scanning.

Aspect ratio correct

Fig. 10. Partial scanning.

- 8 -

Image 9
Contents CV-M4+/M4+CL CV-M7+/M7+CL CV-M4+/M4+CL, CV-M7+/M7+CL Main Features GeneralStandard Composition Locations Locations and FunctionsPin Multi-connector DC-IN/RS232C Digital Output Connector for EIA-644 LvdsPin Assignment Digital Output Connector for Camera Link Video signal, LEN, FEN Dval and EEN Video output Input and Output CircuitsTrigger input Multi Shutter input Composite Sync outputMUX Camera Link interfaceCV-M4+Block Diagram Functions and OperationsBasic functions Binning Color coding from a Primary RGB CCD Bayer filter Color versions CV-M7+and CV-M7+CLRestart Continuous Trigger mode. RCT Output of Timing SignalsPolarity and other functions Continuous Operation Non triggeredVertical timing details, full frame Vertical timing details with 1/2 partial scanning Accumulation latency time for H a-synchronous trigger External Trigger ModesImportant notes on using this mode Edge Pre-select ModeEdge Pre-select, smearless Pulse Width Pulse Width Control ModeFrame Delay Frame-delay read out ModeMultiple exposure, normal and smearless Frame-delay read out Mode with multiple exposureGain and set-up Other FunctionsMode setting SW1 on rear Configuring the CameraMode setting SW301 inside Internal Switch and Jumper SettingsRS-232C control Timing and shutter related commands CV-M4+command listCamera Control Tool for CV-M4+ External Appearance and Dimensions SpecificationsSpectral sensitivity Specifications Specification tablePrecautions Typical CCD CharacteristicsAppendix Camera Link test points Camera Link Test pointsUsers Record Users Mode Settings Users Modifications