Philips Orion/2 manual Dome ID Setting, Dome Control Protocol

Page 11

Orion/2 Outdoor

RS-485 is the interface that communicates the dome camera and its control device; for this reason, the RS-485 setup of the dome and the control device must be the same. The RS-485 default setting is half-duplex (see the diagram as follows). Please do not change the default setting without qualified specialist or supplier’s notice. As for the Pin 3 and Pin 4, they are used for termination and Line Lock adjustment respectively. The Pin 5 is mainly used after firmware upgrade.

RS-485 Setting

Half-duplex

Full-duplex

2.4Dome ID Setting

Use the switch to change your speed dome ID by turning the arrow to the desired number respectively. For instance, if the dome ID is 123, the ID switch should be set as below.

NOTE: No two domes should be given the same ID, or communication conflict may occur.

centesimal

decimal

single digit

NOTE: The number “0” should locate upwards as shown in above diagram for correct switch definition.

2.5Dome Control Protocol

Protocol is a specific set of rules, procedures used for data communications. Basing on the devices of your surveillance system and define the protocol you are going to use. Generally, use one protocol even the devices are provided from different manufacturers. Use the switch to set your dome control protocol and the baud rate. Refer to below table and turn the arrow to choose a protocol for your speed dome.

10

Image 11 Contents
Installation & User Instructions Orion/2 Outdoor Regulation Copyright Important InformationNever face the camera towards the sun Handle the camera carefullyDo not disassemble the camera Do not block cooling holes on the bracketOverview Connecting the High Speed DomeOperation and Configuration Appendix C Protocol-Pelco Appendix D Philips Allegiant Appendix a Technical Specification Appendix B Ernitec ErnaOverview Product Features Package Content Connecting the High Speed DomeCommunication Switch Setting Switch DefinitionDome Control Protocol Dome ID Setting2400 22-Pin Connector Definition11~20 Pin CableFor connection to Ernitec equipment, use Rx+ and Rx Alarm Pin DefinitionRS-485 Connector OSD Display Format Operation and Configuration1 26x Model OSD Menu TreeCruise 2 22x / 23x Model WDR Setting Schedule Reset Schedule Exit 26x Model 22/23x Model Configuration MenuDefault Camera Auto BacklightFocus 26x ModelManual ApertureGain AE ModeBright ShutterAGC WBC ModeATW ID DisplayIndoor OutdoorImage Setup MenuOFF Zoom Speed 23x Model Slow ShutterLast Setup MENU2 26x Model OnlyTitle Display FirstAlarm Setting Title SettingAlarm Action Alarm PINAlarm Switch Alarm TypeHome Setting Return Time Select ModeSequence Speed Preset PositionSequence Line Sequence PointStart Point AutopanDwell Time RUN Sequence Autopan LineRUN Autopan CruiseEND Point DirectionRUN Cruise IR Function Removable IR CutRecord Start Record ENDThreshold Alarm Detect 26x Model OnlyDetect Switch Detect ModeWDR Setting 23x Model Only Transparency Privacy SwitchPrivacy WDR FunctionSize 00~80 ColorSET Mask CenterSize 000~127 Mask CLEAR+RESETShade Center 000~256Year / Month / DAY Time FunctionSchedule Function Time DisplayExit OSD Appendix a Technical Specification Appendix B Ernitec Erna Cruise Tour Run Preset TourIris function Cable Length Symbol DefinitionControl Dome Camera Using Pelco Keyboard Special FunctionCable Definition D Protocol Keyboard to Speed Dome Cable Definition P Protocol Keyboard to Speed DomeAppendix D Philips Allegiant Control Dome Camera Using Allegiant Keyboard26x Model OSD Menu NotesAutopan 22/23x Models WDR Setting