Philips Orion/2 manual Home Setting

Page 33

Orion/2 Outdoor

SEQUENCE

Select a sequence line that the dome camera should execute when alarm pin is triggered. The Sequence line should be defined prior in SEQUENCE setup menu.

AUTOPAN

Select an auto-pan line that the dome camera should execute when alarm pin is triggered. The Auto-pan line can be defined in setup AUTOPAN menu.

CRUISE

Select a cruise line that the dome camera should execute when alarm pin is triggered. The Cruise line can be defined in CRUISE setup menu.

DWELL TIME

The DWELL TIME is the duration of executing ALARM ACTION: Preset or Sequence. When alarm takes place, the dome will go to the preset position or execute sequence function and stay at each sequence point for a period of time (1~127 seconds). If select <Always>, the dome will go to the preset position and stay there until alarm condition is released or users rotate the dome.

NOTE: The DWELL TIME is only accessible when selecting ALARM

ACTION: Preset or Sequence.

EXIT

Exit the ALARM SETTING menu.

3.3.13HOME SETTING

Users are able to set an operation mode to ensure constant monitoring; if the dome idles for a period of time, the pre-set function will be activated automatically, this is the HOME function. HOME function allows constant and accurate monitoring, to avoid the dome stops or missing events.

HOME SETTING

 

HOME FUNCTION

OFF

SELECT MODE

PRESET

PRESET POINT

001

RETURN TIME

001

GO

ENTER

EXIT

YES

HOME FUNCTION

The item is used to enable or disable the HOME function. Use the left/right direction keys of the control keyboard to change the setting.

32

Image 33
Contents Installation & User Instructions Orion/2 Outdoor Regulation Copyright Important InformationDo not disassemble the camera Handle the camera carefullyDo not block cooling holes on the bracket Never face the camera towards the sunConnecting the High Speed Dome Operation and ConfigurationOverview Appendix C Protocol-Pelco Appendix D Philips Allegiant Appendix a Technical Specification Appendix B Ernitec ErnaOverview Product Features Package Content Connecting the High Speed DomeCommunication Switch Setting Switch DefinitionDome Control Protocol Dome ID Setting2400 22-Pin Connector Definition11~20 Pin CableAlarm Pin Definition RS-485 ConnectorFor connection to Ernitec equipment, use Rx+ and Rx OSD Display Format Operation and Configuration1 26x Model OSD Menu TreeCruise 2 22x / 23x Model WDR Setting Schedule Reset Schedule Exit Configuration Menu Default Camera26x Model 22/23x Model Focus Backlight26x Model AutoManual ApertureBright AE ModeShutter GainAGC WBC ModeIndoor ID DisplayOutdoor ATWSetup Menu OFFImage Zoom Speed 23x Model Slow ShutterTitle Display Setup MENU2 26x Model OnlyFirst LastAlarm Setting Title SettingAlarm Switch Alarm PINAlarm Type Alarm ActionHome Setting Select Mode SequenceReturn Time Sequence Line Preset PositionSequence Point SpeedDwell Time RUN Sequence AutopanAutopan Line Start PointEND Point CruiseDirection RUN AutopanRecord Start IR Function Removable IR CutRecord END RUN CruiseDetect Switch Alarm Detect 26x Model OnlyDetect Mode ThresholdWDR Setting 23x Model Only Privacy Privacy SwitchWDR Function TransparencySET Mask ColorCenter Size 00~80Shade Mask CLEAR+RESETCenter 000~256 Size 000~127Schedule Function Time FunctionTime Display Year / Month / DAYExit OSD Appendix a Technical Specification Appendix B Ernitec Erna Run Preset Tour Iris functionCruise Tour Control Dome Camera Using Pelco Keyboard Symbol DefinitionSpecial Function Cable LengthCable Definition D Protocol Keyboard to Speed Dome Cable Definition P Protocol Keyboard to Speed DomeAppendix D Philips Allegiant Control Dome Camera Using Allegiant Keyboard26x Model OSD Menu NotesAutopan 22/23x Models WDR Setting