Philips Orion/2 manual ID Display, Indoor, Outdoor, Atw

Page 26

Orion/2 Outdoor

computes the white balance value output using color information from the entire screen. It outputs the proper value using the color temperature radiating from a black subject based on a range of values from 3000K to 7500K.

INDOOR

3200 K Base mode.

OUTDOOR

5800 K Base mode.

ATW

Auto Tracing White Balance mode. The dome taking out the signals in a screen in the range from 2000 K to 10000 K.

MANUAL

In this mode, users can change the White Balance value manually; R gain and B gain are adjustable and range from 0 to 128.

 

WBC MENU

R GAIN

50

B GAIN

50

22/23x Model:

AUTO

In this mode, white balance works within its color temperature range and calculates the best-fit white balance.

MANUAL

In this mode, users can change the White Balance value manually; adjustable R gain and B gain range from 0 to 99.

 

WBC MENU

R GAIN

50

B GAIN

50

3.3.7ID DISPLAY

Users are allowed to choose whether the dome ID will be displayed on monitor to identify the domes. For more information, please refer to section 2.4 Dome ID Setting.

ON

Display the ID address of the selected dome on the right bottom of the monitor screen.

25

Image 26
Contents Installation & User Instructions Orion/2 Outdoor Copyright Important Information RegulationDo not block cooling holes on the bracket Handle the camera carefullyDo not disassemble the camera Never face the camera towards the sunOverview Connecting the High Speed DomeOperation and Configuration Appendix a Technical Specification Appendix B Ernitec Erna Appendix C Protocol-Pelco Appendix D Philips AllegiantOverview Product Features Connecting the High Speed Dome Package ContentSwitch Definition Communication Switch SettingDome ID Setting Dome Control Protocol22-Pin Connector Definition 2400Pin Cable 11~20For connection to Ernitec equipment, use Rx+ and Rx Alarm Pin DefinitionRS-485 Connector Operation and Configuration OSD Display FormatOSD Menu Tree 1 26x ModelCruise 2 22x / 23x Model WDR Setting Schedule Reset Schedule Exit 26x Model 22/23x Model Configuration MenuDefault Camera 26x Model BacklightFocus AutoAperture ManualShutter AE ModeBright GainWBC Mode AGCOutdoor ID DisplayIndoor ATWImage Setup MenuOFF Zoom Speed Slow Shutter 23x ModelFirst Setup MENU2 26x Model OnlyTitle Display LastTitle Setting Alarm SettingAlarm Type Alarm PINAlarm Switch Alarm ActionHome Setting Return Time Select ModeSequence Sequence Point Preset PositionSequence Line SpeedAutopan Line AutopanDwell Time RUN Sequence Start PointDirection CruiseEND Point RUN AutopanRecord END IR Function Removable IR CutRecord Start RUN CruiseDetect Mode Alarm Detect 26x Model OnlyDetect Switch ThresholdWDR Setting 23x Model Only WDR Function Privacy SwitchPrivacy TransparencyCenter ColorSET Mask Size 00~80Center 000~256 Mask CLEAR+RESETShade Size 000~127Time Display Time FunctionSchedule Function Year / Month / DAYExit OSD Appendix a Technical Specification Appendix B Ernitec Erna Cruise Tour Run Preset TourIris function Special Function Symbol DefinitionControl Dome Camera Using Pelco Keyboard Cable LengthCable Definition P Protocol Keyboard to Speed Dome Cable Definition D Protocol Keyboard to Speed DomeControl Dome Camera Using Allegiant Keyboard Appendix D Philips AllegiantOSD Menu Notes 26x ModelAutopan 22/23x Models WDR Setting