Philips Orion/2 manual OSD Menu Notes, 26x Model

Page 52

Orion/2 Outdoor

OSD Menu Notes

The following OSD menu tables are provided for users to record the dome settings.

26x Model

 

 

Item

Layer 1

Layer 2

 

Layer 3

Note

 

 

 

DEFAULT CAMERA

 

<ON>, <OFF>

 

 

 

 

 

 

 

BACKLIGHT

 

<ON>, <OFF>

 

 

 

 

 

 

 

FOCUS

 

AUTO

AF Mode <Normal>, <Interval>, <Zoom Trigger>

 

 

 

 

 

MANUAL

Focus Manual Speed <01>~<08>

 

 

 

 

 

 

 

 

 

 

 

 

AUTO

Exposure Comp. <OFF>, <1>~<15>

 

 

 

 

 

 

BRIGHT

Bright <0> ~ <31>

 

 

 

 

AE MODE

 

SHUTTER

Shutter Speed <1> ~ <1/10000> Sec.

 

 

 

 

 

 

GAIN

Gain <-3> ~ <28>dB

 

 

 

 

 

 

IRIS

Iris <Close>, <F1.6> ~ <F28>

 

 

 

 

 

 

AUTO (Auto White Balance)

 

 

 

 

 

 

 

 

 

INDOOR

 

 

 

 

 

 

 

WBC MODE

 

OUTDOOR

 

 

 

 

 

 

 

 

ATW (Auto-tracing WBC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUAL

R Gain

<000> ~ <128>

 

 

 

 

 

 

 

 

B Gain

<000> ~ <128>

 

 

 

 

 

ID DISPLAY

 

<ON>, <OFF>

 

 

 

 

 

 

 

 

 

FLIP

<IMAGE>, <M.E.>, <OFF>

 

 

 

 

 

 

ZOOM SPEED

<1> ~ <8>

 

 

 

 

 

 

 

SPEED BY ZOOM

<ON>, <OFF>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO CALI.

<ON>, <OFF>

 

 

 

 

SETUP MENU 1

 

DIGITAL ZOOM

<ON>, <OFF>

 

 

 

 

 

SLOW SHUTTER

<ON>, <OFF>

 

 

 

 

 

 

 

 

 

 

 

 

ANGLE ADJUSTER

ADJUST MIN ANGLE

 

 

 

 

 

 

 

ADJUST MAX ANGLE

 

 

 

 

 

 

 

RESET

 

 

 

 

 

 

 

 

RESET

<YES>

 

 

 

 

 

 

 

 

EXIT

 

 

 

 

 

 

 

SETUP MENU 2

 

APERTURE

<01> ~ <16>

 

 

 

 

 

 

MASK DISPLAY

<FIRST>, <LAST>

 

 

 

 

 

 

 

 

 

 

TITLE DISPLAY

<ON>, <OFF>

 

 

 

 

 

 

 

TITLE SETTING

<01> ~ <16>

 

 

 

 

 

 

 

 

 

ALARM PIN

<1> ~ <8>

 

 

 

 

 

 

 

ALARM SWITCH

<ON>, <OFF>

 

 

 

 

 

 

ALARM TYPE

<N.O.> (Normal Open), <N.C.> (Normal Close)

 

 

 

 

 

 

ALARM ACTION

PRESET

 

 

 

 

 

 

 

 

 

SEQUENCE

 

 

 

 

 

 

 

AUTOPAN

 

 

 

 

ALARM SETTNG

 

 

CRUISE

 

 

 

 

 

 

 

 

PRESET POINT

<001> ~ <256>

 

 

 

 

 

 

 

SEQUENCE LINE

<1> ~ <8>

 

 

 

 

 

 

 

AUTOPAN LINE

<1> ~ <4>

 

 

 

 

 

 

 

CRUISE LINE

<1>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DWELL TIME

<001> ~ <127> Sec., <ALWAYS>

 

 

 

 

 

 

EXIT

YES

 

 

 

 

 

 

 

 

HOME FUNC.

<ON>, <OFF>

 

 

 

 

 

 

SELECT MODE

PRESET

 

 

 

 

 

 

 

 

 

SEQUENCE

 

 

 

 

 

 

 

AUTOPAN

 

 

 

 

 

 

 

CRUISE

 

 

 

 

 

 

HOME SETTING

 

PRESET POINT

<001> ~ <256>

 

 

 

 

 

 

SEQUENCE LINE

<1> ~ <8>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTOPAN LINE

<1> ~ <4>

 

 

 

 

 

 

 

CRUISE LINE

<1>

 

 

 

 

 

 

 

 

RETURN TIME

<001> ~ <128> Min.

 

 

 

 

 

 

GO

ENTER

 

 

 

 

 

 

 

 

EXIT

 

 

 

 

 

 

 

SEQUENCE

 

SEQUENCE LINE

<1> ~ <8>

 

 

 

 

 

 

 

 

 

 

 

 

 

51

Image 52
Contents Installation & User Instructions Orion/2 Outdoor Copyright Important Information RegulationHandle the camera carefully Do not disassemble the cameraDo not block cooling holes on the bracket Never face the camera towards the sunOperation and Configuration Connecting the High Speed DomeOverview Appendix a Technical Specification Appendix B Ernitec Erna Appendix C Protocol-Pelco Appendix D Philips AllegiantOverview Product Features Connecting the High Speed Dome Package ContentSwitch Definition Communication Switch SettingDome ID Setting Dome Control Protocol22-Pin Connector Definition 2400Pin Cable 11~20RS-485 Connector Alarm Pin DefinitionFor connection to Ernitec equipment, use Rx+ and Rx Operation and Configuration OSD Display FormatOSD Menu Tree 1 26x ModelCruise 2 22x / 23x Model WDR Setting Schedule Reset Schedule Exit Default Camera Configuration Menu26x Model 22/23x Model Backlight Focus26x Model AutoAperture ManualAE Mode BrightShutter GainWBC Mode AGCID Display IndoorOutdoor ATWOFF Setup MenuImage Zoom Speed Slow Shutter 23x ModelSetup MENU2 26x Model Only Title DisplayFirst LastTitle Setting Alarm SettingAlarm PIN Alarm SwitchAlarm Type Alarm ActionHome Setting Sequence Select ModeReturn Time Preset Position Sequence LineSequence Point SpeedAutopan Dwell Time RUN SequenceAutopan Line Start PointCruise END PointDirection RUN AutopanIR Function Removable IR Cut Record StartRecord END RUN CruiseAlarm Detect 26x Model Only Detect SwitchDetect Mode ThresholdWDR Setting 23x Model Only Privacy Switch PrivacyWDR Function TransparencyColor SET MaskCenter Size 00~80Mask CLEAR+RESET ShadeCenter 000~256 Size 000~127Time Function Schedule FunctionTime Display Year / Month / DAYExit OSD Appendix a Technical Specification Appendix B Ernitec Erna Iris function Run Preset TourCruise Tour Symbol Definition Control Dome Camera Using Pelco KeyboardSpecial Function Cable LengthCable Definition P Protocol Keyboard to Speed Dome Cable Definition D Protocol Keyboard to Speed DomeControl Dome Camera Using Allegiant Keyboard Appendix D Philips AllegiantOSD Menu Notes 26x ModelAutopan 22/23x Models WDR Setting