Philips Orion/2 manual Zoom Speed

Page 28

Orion/2 Outdoor

M.E.

The item is a standard mechanical operation. As the dome tilts 90°, it will pan 180°, then continuing tilt to keep tracking object.

OFF

Select this item to disable the flip function.

NOTE: The dome will only be able to tilt 90°, or -10° ~100° with angle adjuster adjustments.

ZOOM SPEED

This item is used to set the zoom speed for operating the dome camera.

26x Model:

For these models, the zoom speed options are <1> (slow) ~ <8> (fast). The default is <8>.

22/23x Model:

For the two models, the options are <FAST> and <SLOW> (default).

SPEED BY ZOOM

If the item is set to <ON>, the pan/tilt speed will be adjusted by internal algorithm when zooming automatically. The larger zoom ratio leads the lower rotation speed.

AUTO CALIBRATION

There are one horizontal and one vertical infrared rays check points in each dome. When the dome camera position may be moved during installation or maintenance, the relative distance between the original set point and the check point has been changed. Enable the Auto Calibration function, the dome will automatically detect that and reset the point back to the original position.

DIGITAL ZOOM

With this item, users can enable or disable the 12× Digital Zoom. The Digital Zoom activate after the full Optical Zoom level is reached.

NOTE: The difference between optical and digital zoom is that optical zoom uses the lens within the camera to draw the image closer via zoom in or out to achieve the desired effect. Optical zoom remains the same and the full resolution of the zoomed image quality. On the other hand, Digital zoom takes a portion of image and expands that image to the full size of the image; however the image quality will be reduced.

27

Image 28
Contents Installation & User Instructions Orion/2 Outdoor Copyright Important Information RegulationHandle the camera carefully Do not disassemble the cameraDo not block cooling holes on the bracket Never face the camera towards the sunOperation and Configuration Connecting the High Speed DomeOverview Appendix a Technical Specification Appendix B Ernitec Erna Appendix C Protocol-Pelco Appendix D Philips AllegiantOverview Product Features Connecting the High Speed Dome Package ContentSwitch Definition Communication Switch SettingDome ID Setting Dome Control Protocol22-Pin Connector Definition 2400Pin Cable 11~20RS-485 Connector Alarm Pin DefinitionFor connection to Ernitec equipment, use Rx+ and Rx Operation and Configuration OSD Display FormatOSD Menu Tree 1 26x ModelCruise 2 22x / 23x Model WDR Setting Schedule Reset Schedule Exit Default Camera Configuration Menu26x Model 22/23x Model Backlight Focus26x Model AutoAperture ManualAE Mode BrightShutter GainWBC Mode AGCID Display IndoorOutdoor ATWOFF Setup MenuImage Zoom Speed Slow Shutter 23x ModelSetup MENU2 26x Model Only Title DisplayFirst LastTitle Setting Alarm SettingAlarm PIN Alarm SwitchAlarm Type Alarm ActionHome Setting Sequence Select ModeReturn Time Preset Position Sequence LineSequence Point SpeedAutopan Dwell Time RUN SequenceAutopan Line Start PointCruise END PointDirection RUN AutopanIR Function Removable IR Cut Record StartRecord END RUN CruiseAlarm Detect 26x Model Only Detect SwitchDetect Mode ThresholdWDR Setting 23x Model Only Privacy Switch PrivacyWDR Function TransparencyColor SET MaskCenter Size 00~80Mask CLEAR+RESET ShadeCenter 000~256 Size 000~127Time Function Schedule FunctionTime Display Year / Month / DAYExit OSD Appendix a Technical Specification Appendix B Ernitec Erna Iris function Run Preset TourCruise Tour Symbol Definition Control Dome Camera Using Pelco KeyboardSpecial Function Cable LengthCable Definition P Protocol Keyboard to Speed Dome Cable Definition D Protocol Keyboard to Speed DomeControl Dome Camera Using Allegiant Keyboard Appendix D Philips AllegiantOSD Menu Notes 26x ModelAutopan 22/23x Models WDR Setting