Philips Orion/2 manual Color, SET Mask, Center, Size 00~80, Size 00~60

Page 42

Orion/2 Outdoor

COLOR

The color of privacy mask can be set through this item. The available colors are black, heavy gray, light gray, white, red, green, blue, cyan, yellow and magenta.

SET MASK

Use the control device to move the dome camera to the area whether you want to set a mask. Press <ENTER> to enter MASK SETUP MENU. The dome will memorize this position as privacy mask position. Up to 24 masks can be set.

MASK01 MENU

 

H CENTER

L/R

V CENTER

U/D

H SIZE

000

V SIZE

000

EXIT+SAVE

YES

H CENTER

The original horizontal center of mask zone is the center of screen; it is able to move to other position by adjusting the horizontal value with the LEFT/RIGHT keys.

V CENTER

The original vertical center of mask zone is the center of screen; it is able to move to other position by adjusting the vertical value with the LEFT/RIGHT keys.

H SIZE (00~80)

User can adjust the horizontal size of privacy mask through this item. Set the H and V size to 0 can also delete the selected mask.

V SIZE (00~60)

User can adjust the vertical size of privacy mask through this item. Set the H and V size to 0 can also delete the selected mask.

EXIT

Exit this page.

23x Model:

PRIVACY

 

PRIVACY SWITCH

ON

SHADE

GRAY

SET MASK

01

MASK CLEAR+RESET

01

MASK DISPLAY

FIRST

EXIT

YES

PRIVACY SWITCH

The item is used to enable or disable masking function. Set this item to <ON> before configuring mask zone.

41

Image 42
Contents Installation & User Instructions Orion/2 Outdoor Copyright Important Information RegulationDo not block cooling holes on the bracket Handle the camera carefullyDo not disassemble the camera Never face the camera towards the sunConnecting the High Speed Dome Operation and ConfigurationOverview Appendix a Technical Specification Appendix B Ernitec Erna Appendix C Protocol-Pelco Appendix D Philips AllegiantOverview Product Features Connecting the High Speed Dome Package ContentSwitch Definition Communication Switch SettingDome ID Setting Dome Control Protocol22-Pin Connector Definition 2400Pin Cable 11~20Alarm Pin Definition RS-485 ConnectorFor connection to Ernitec equipment, use Rx+ and Rx Operation and Configuration OSD Display FormatOSD Menu Tree 1 26x ModelCruise 2 22x / 23x Model WDR Setting Schedule Reset Schedule Exit Configuration Menu Default Camera26x Model 22/23x Model 26x Model BacklightFocus AutoAperture ManualShutter AE ModeBright GainWBC Mode AGCOutdoor ID DisplayIndoor ATWSetup Menu OFFImage Zoom Speed Slow Shutter 23x ModelFirst Setup MENU2 26x Model OnlyTitle Display LastTitle Setting Alarm SettingAlarm Type Alarm PINAlarm Switch Alarm ActionHome Setting Select Mode SequenceReturn Time Sequence Point Preset PositionSequence Line SpeedAutopan Line AutopanDwell Time RUN Sequence Start PointDirection CruiseEND Point RUN AutopanRecord END IR Function Removable IR CutRecord Start RUN CruiseDetect Mode Alarm Detect 26x Model OnlyDetect Switch ThresholdWDR Setting 23x Model Only WDR Function Privacy SwitchPrivacy TransparencyCenter ColorSET Mask Size 00~80Center 000~256 Mask CLEAR+RESETShade Size 000~127Time Display Time FunctionSchedule Function Year / Month / DAYExit OSD Appendix a Technical Specification Appendix B Ernitec Erna Run Preset Tour Iris functionCruise Tour Special Function Symbol DefinitionControl Dome Camera Using Pelco Keyboard Cable LengthCable Definition P Protocol Keyboard to Speed Dome Cable Definition D Protocol Keyboard to Speed DomeControl Dome Camera Using Allegiant Keyboard Appendix D Philips AllegiantOSD Menu Notes 26x ModelAutopan 22/23x Models WDR Setting