Sanyo VCC-MD600 Model VCC-MD800/700/600/500/400/300, Example Motion Mask Area Settings Figure

Page 21

Communications Protocol

Model: VCC-MD800/700/600/500/400/300

[7] Notes

Note 1 Area Settings

Divide the screen into 48 areas (6 vertical and 8 horizontal) and set an area to “1” to configure the mask and “0” to not configure the mask. On a row, bits 1 to 4 from the left are on the upper level and bits 5 to 8 are on the lower level. All six rows are connected in order from the top and transmitted according to protocol.

Example: Motion Mask Area Settings (Figure 1)

When setting Figure 1 (the area covered in black shows the position of the mask), transmit in the order described below.

A0

Header

08

Motion Command

13

Motion Area Settings

07

First Row (00000111

00

0111, 0000)

07

Second Row (00000111

00

0111, 0000)

07

Third Row (01100111

06

0111, 0110)

00

Fourth Row (01100000

06

0000, 0110)

00

Fifth Row (01100000

06

0000, 0110)

02

Sixth Row (00000010

00

0010, 0000)

CS

Checksum

FF

Terminator

*The setting commands for the ATW Mask Area, Mask BLC Area are also transmitted using the procedure described above.

*The Motion Detection Area (Query command Status type 8) also responds in the order described above. (The area where motion is detected is set to “1”.)

− 20 −

Image 21
Contents Technical Manual VVer Contents Parts Names and Dimensions DimensionsVCC-MD800/700/600/500 Series VCC-MD400/MD300 Series Parts Names and DimensionsInterface Board Specifications ConnectionConnection of the Interface Board and Camera Unit External Synchronous Signals Input-Output Terminal Layout and SpecificationsInput-Output Terminal Descriptions FFC ComplianceCommunications Format Communications ProtocolDuring Settings Command During Query Command ACKDuring Query Command Other than ACK Communications FlowCommand List for MD800-500 ATWMWB BLC on BLC OFFELS OFF ELS onAGC ON/OFF AGCOFF SMART1Alarm OUT on Line OUT OFF Alarm Alarm OUT OFFOSD EepromCS FF Command List Query for MD800-500− 13 − − 14 − Command List for MD400 − 16 − − 17 − Burst on Level DAY ColorADJ Direct B Command List Query for MD400Model VCC-MD800/700/600/500/400/300 Example Motion Mask Area Settings Figure⁃⁃ Status Command 3 Only MD400 ⁃⁃ Status Command 2 Except for MD300⁃⁃ Status Command 4 Only MD800/700/600/500 ⁃⁃ Status Command 5 Only MD800/700/600/500⁃ ⁃ Status Command 6 Only MD800/700/600/500 ⁃⁃ When setting Sense UP Auto switch setting⁃⁃ When setting the motion setting to on When unable to set ⁃⁃ When setting V-RESO UP to on When unable to setModel Code Communications Protocol Zoom Control Function DescriptionsZoom Position Control ⁃⁃ Direct ⁃⁃ Tele/WideWhite Balance Control Focus ControlIris Control Shutter Speed ControlAGC Control Backlight Compensation 10 Day/Night Switch Control ApertureMotion Detection Setting the Mask Angle Area Mask Degree Set Privacy Mask Settings Display Area Ntsc PALDetails of the Mask Angle and Position Area Mask Degree SetSetting the Mask Position Area Mask Position Set To clarify the image when using the stabilizer StabilizerFrequency that can be stabilized Auto Pursuit Function Moving Distance Query CommandCommunications Error Camera Control Command TransmissionApplication Software RS-232C PortSpectral Sensitivity Characteristics Ntsc system SpecificationsPAL system Change history Change history