Sanyo VCC-MD600, VCC-MD400P, VCC-MD500, VCC-MD300P Command List for MD800-500, Atw, Mwb

Page 9

Communications Protocol

 

 

 

 

Model: VCC-MD800/700/600/500

[3] Command List for MD800-500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Message

 

 

 

 

 

 

 

 

 

 

 

 

 

System

 

All Initial

A0

01

0A

CS

FF

 

 

 

 

Initialization of Unadjusted EEPROM Values (Set to Factory Defaults)

 

 

 

All Menu Initial

A0

01

0B

CS

FF

 

 

 

 

Initialization of All Menu Settings

 

 

 

Lens Initial

A0

01

0C

CS

FF

 

 

 

 

Detection of initial lens position

 

 

 

Reset

A0

01

0D

CS

FF

 

 

 

 

Restarting camera (Saves the setting value)

 

 

 

Menu Initial

A0

01

0E

CS

FF

 

 

 

 

Initialization of menu settings other than privacy mask settings

 

 

 

Pixel defect compensation

A0

01

12

00

06

04

04

06

00

Applied version 1.21-** or later

(Note 8)

 

 

 

0C

CS

FF

 

 

 

 

 

 

 

 

 

Auto pixel defect

A0

01

13

0p

CS

FF

 

 

 

p: 0:OFF Default , 1:ON

 

 

 

compensation at start-up.

 

 

 

 

 

 

 

 

 

Applied version 1.21-** or later

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to "Communications Protocol [2]Communications Flow"

 

Zoom

 

Tele

A0

02

05

CS

FF

 

 

 

 

 

 

 

 

Wide

A0

02

06

CS

FF

 

 

 

 

 

 

 

 

Tele/Wide Stop

A0

02

07

CS

FF

 

 

 

 

 

 

 

 

Tele/Wide Speed

A0

02

08

0p

CS

FF

 

 

 

p: Speed 1-4 during Tele and Wide commands (1: Slow-4: Fast [Initial value: 3])

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direct

A0

02

09

0p

0q

0r

CS

FF

 

pqr: Direct Position

 

 

 

 

 

 

 

 

 

 

 

 

 

MD800/700, 0: Wide, 2484: 36x (optical), 2724: 576x (digital)

 

 

 

 

 

 

 

 

 

 

 

 

 

MD600/500, 0: Wide, 2263: 30x (optical), 2503: 480x (digital)

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Zoom Tele Limiter command needs to be sent before moving to digital zoom field.

 

 

 

Zoom Direct with Focus

A0

02

0A

0p

0q

0r

0s

0t

0u

pqr:Zoom Direct Position stu:Focus Direct Position

 

 

 

 

CS

FF

 

 

 

 

 

 

For carrying set the focus to the specified position.

 

 

 

Digital Zoom Tele Limiter

A0

02

18

0p

CS

FF

 

 

 

p: Maximum digital zoom magnification (0: x0 [Initial value], 1: x2, 2: x4, 3: x8, 4: x16)

 

 

 

Optical Zoom Wide/Tele

A0

02

19

xx

yy

CS

FF

 

 

Wide/Tele Optical ZOOM Limiter The numbers within the brackets refer to the MD600/500 models

 

 

Limitter

 

 

 

 

 

 

 

 

 

xx: 0, 1-35 [29] (0 is no limit and 1-35 [29] is the Wide optical ZOOM limit)

 

 

 

 

 

 

 

 

 

 

 

 

 

yy: 0, 2-36 [30] (0 is no limit and 2-36 [30] is the Tele optical ZOOM limit)

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Ensure that xx < yy

 

 

 

V-Reso.UP OFF/ON

A0

02

1F

0p

CS

FF

 

 

 

p: Increased vertical sensitivity settings during digital zoom OFF/ON (0: OFF, 1: ON)

(Note 3)

 

 

Zoom Preset ON

A0

02

28

CS

FF

 

 

 

 

Moves the zoom position to the optical TELE edge

 

 

 

Zoom Preset OFF

A0

02

29

CS

FF

 

 

 

 

Returns the zoom position to the position before the “Zoom Preset ON” operation

 

Focus

 

Auto Focus ON

A0

03

00

CS

FF

 

 

 

 

 

 

 

 

Manual Focus ON

A0

03

01

CS

FF

 

 

 

 

 

 

 

 

One Push Trigger

A0

03

03

CS

FF

 

 

 

 

Operates the auto focus operation once

 

 

 

Far

A0

03

05

CS

FF

 

 

 

 

 

 

 

 

Near

A0

03

06

CS

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Far/Near Stop

A0

03

07

CS

FF

 

 

 

 

 

 

 

 

Far/Near Speed

A0

03

08

0p

CS

FF

 

 

 

p: Speed 1-4 during Far and Near commands (1: Slow-4: Fast (Initial value: 2))

 

 

 

Direct

A0

03

09

0p

0q

0r

CS

FF

 

pqr: Direct Position (0: Far 1209: Near)

 

 

 

Near Limiter

A0

03

0E

0p

CS

FF

 

 

 

p: Subject distance limit during auto focus and manual focus

 

 

 

 

 

 

 

 

 

 

 

 

 

(0: 10 cm, 1: 30cm, 2: 50 cm, 3: 1 m [Initial value], 4: 3 m, 5: 5 m)

 

 

 

Auto Focus Sensitivity

A0

03

10

0p

CS

FF

 

 

 

p: Auto focus restart sensitivity settings (0: LOW/1: HI [Initial value])

 

 

 

Focus Area

A0

03

13

0p

CS

FF

 

 

 

Settings Determining Auto Focus Areas 1-3

 

 

 

 

 

 

 

 

 

 

 

 

 

1: Entire screen-3: Only center of the screen (Initial value: 2)

 

 

 

Cover Offset OFF/ON

A0

03

15

0p

CS

FF

 

 

 

p: Offset OFF/ON (0: OFF/1: ON) when using the cover

 

 

 

Cover Offset Level

A0

03

16

0p

0q

CS

FF

 

 

pq: Offset Level Setting 0 – 00 (Initial value: 5) when using the cover

 

 

 

Auto Focus Mode during pan/tilt

A0

03

1F

0p

CS

FF

 

 

 

p: Auto Focus Mode Setting during Pan/Tilt (0: AF/1: Fixed)

 

White

 

ATW

A0

04

00

CS

FF

 

 

 

 

Auto White Balance Mode (Same as "0" in WB Mode)

 

Balance

 

MWB

A0

04

01

CS

FF

 

 

 

 

Manual White Balance Mode (Same as "2" in WB Mode)

 

 

 

One Push Trigger (AWC Set)

A0

04

03

CS

FF

 

 

 

 

Executes OnePush in AWC Mode

 

 

 

AWC Reset

A0

04

04

CS

FF

 

 

 

 

Returns to the original mode only after executing the OnePush Trigger command

 

 

 

ATW Smart OFF/ON

A0

04

06

0p

CS

FF

 

 

 

Smart ATW (high color saturation compensation) ON/OFF (OFF: 0 [Initial value], ON: 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

*This mode is valid when WB mode is set to ATW.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WB Mode

A0

04

07

0p

CS

FF

 

 

 

p: White Balance Mode 0-5

 

 

 

 

 

 

 

 

 

 

 

 

 

0: Auto White Balance, 1: AWC Mode (One-Push N/A), 2: Manual White Balance

 

 

 

 

 

 

 

 

 

 

 

 

 

3: 3200K Fixed Mode, 4: 5600K Fixed Mode, 5: FLUO Mode (4200K Fixed)

 

 

 

MWB Red +

A0

04

0B

CS

FF

 

 

 

 

 

 

 

 

MWB Red -

A0

04

0C

CS

FF

 

 

 

 

 

 

 

 

MWB Red Preset

A0

04

0F

CS

FF

 

 

 

 

Returns MWB red component settings to factory defaults (Initial value: 64)

 

 

 

MWB Red Direct

A0

04

13

0p

0q

CS

FF

 

 

pq: Direct MWB red components 0-255

 

 

 

MWB Blue +

A0

04

15

CS

FF

 

 

 

 

 

 

 

 

MWB Blue -

A0

04

16

CS

FF

 

 

 

 

 

 

 

 

MWB Blue Preset

A0

04

19

CS

FF

 

 

 

 

Returns MWB blue component settings to factory defaults (Initial value: 64)

 

 

 

MWB Blue Direct

A0

04

1D

0p

0q

CS

FF

 

 

pq: Direct MWB blue components 0-255

 

 

 

ATW Masking OFF

A0

04

28

CS

FF

 

 

 

 

Mask settings ON/OFF during ATW

 

 

 

ATW Masking ON

A0

04

29

CS

FF

 

 

 

 

 

 

 

 

ATW Mask Area Clr

A0

04

2D

CS

FF

 

 

 

 

Initialization of mask settings during ATW

 

 

 

ATW Mask Area Set

A0

04

31

0p

0q

0r

0s

0t

0u

Mask area settings during ATW

(Note 1)

 

 

 

0v

0w

0x

0y

0z

0n

CS

FF

 

 

 

 

ATW Mask Display

A0

04

32

0p

CS

FF

 

 

 

p: Displays the ATW MASK settings status on the monitor. (1: ON/0: OFF)

 

Iris

 

Auto IRIS

A0

05

00

CS

FF

 

 

 

 

 

(Note 3)

 

 

Manual IRIS (EI OFF)

A0

05

01

CS

FF

 

 

 

 

 

 

 

 

Manual IRIS (EI ON)

A0

05

02

CS

FF

 

 

 

 

 

(Note 3)

 

 

Iris Level +

A0

05

0B

CS

FF

 

 

 

 

Iris level operation during auto iris

 

 

 

Iris Level -

A0

05

0C

CS

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Iris Level Preset

A0

05

0F

CS

FF

 

 

 

 

Returns iris levels during auto iris to factory defaults (Initial value: 40)

 

 

 

Iris Level Direct

A0

05

13

0p

0q

CS

FF

 

 

pq: Iris level 0 (Dark) - 100 (Bright) during auto iris (Initial value: 40)

 

 

 

Manual Iris Stop +

A0

05

15

CS

FF

 

 

 

 

Aperture operation during manual iris (Initial value: 17)

 

 

 

Manual Iris Stop -

A0

05

16

CS

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual Iris Stop Preset

A0

05

19

CS

FF

 

 

 

 

Returns aperture during manual iris to factory default (Initial value: 17)

 

 

 

Manual Iris Stop Direct

A0

05

1D

p

CS

FF

 

 

 

p: Aperture 1 (Close) - 17 (Open) during manual iris

 

 

CS: Checksum

 

 

 

 

 

 

 

 

 

 

 

 

FF: Terminator

 

 

 

 

 

 

 

 

 

 

 

− 8 −

Image 9
Contents Technical Manual VVer Contents Parts Names and Dimensions DimensionsVCC-MD800/700/600/500 Series VCC-MD400/MD300 Series Parts Names and DimensionsInterface Board Specifications ConnectionConnection of the Interface Board and Camera Unit External Synchronous Signals Input-Output Terminal Layout and SpecificationsInput-Output Terminal Descriptions FFC ComplianceCommunications Format Communications ProtocolDuring Settings Command During Query Command ACKDuring Query Command Other than ACK Communications FlowCommand List for MD800-500 ATWMWB BLC on BLC OFFELS OFF ELS onAGC ON/OFF AGCOFF SMART1Alarm OUT on Line OUT OFF Alarm Alarm OUT OFFOSD EepromCS FF Command List Query for MD800-500− 13 − − 14 − Command List for MD400 − 16 − − 17 − Burst on Level DAY ColorADJ Direct B Command List Query for MD400Model VCC-MD800/700/600/500/400/300 Example Motion Mask Area Settings Figure⁃⁃ Status Command 3 Only MD400 ⁃⁃ Status Command 2 Except for MD300⁃⁃ Status Command 4 Only MD800/700/600/500 ⁃⁃ Status Command 5 Only MD800/700/600/500⁃ ⁃ Status Command 6 Only MD800/700/600/500 ⁃⁃ When setting Sense UP Auto switch setting⁃⁃ When setting the motion setting to on When unable to set ⁃⁃ When setting V-RESO UP to on When unable to setModel Code Communications Protocol Zoom Control Function DescriptionsZoom Position Control ⁃⁃ Direct ⁃⁃ Tele/WideWhite Balance Control Focus ControlIris Control Shutter Speed ControlAGC Control Backlight Compensation 10 Day/Night Switch Control ApertureMotion Detection Setting the Mask Angle Area Mask Degree Set Privacy Mask Settings Display Area Ntsc PALDetails of the Mask Angle and Position Area Mask Degree SetSetting the Mask Position Area Mask Position Set To clarify the image when using the stabilizer StabilizerFrequency that can be stabilized Auto Pursuit Function Moving Distance Query CommandCommunications Error Camera Control Command TransmissionApplication Software RS-232C PortSpectral Sensitivity Characteristics Ntsc system SpecificationsPAL system Change history Change history