Communications Protocol

 

 

 

 

 

Model: VCC-MD400/300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Message

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Backlight

 

BLC OFF

 

A0

06

00

CS

FF

 

 

 

 

Backlight compensation OFF

 

 

 

Multi BLC ON

 

A0

06

01

CS

FF

 

 

 

 

Backlight compensation multifractionated evaluative metering mode (Backlight compensates after

 

 

 

 

 

 

 

 

 

 

 

 

 

measuring the light of the entire screen.)

 

 

 

Multi BLC Weight -

A0

06

04

00

CS

FF

 

 

 

Sensitivity settings during Multi BLC

 

 

 

Multi BLC Weight +

A0

06

04

01

CS

FF

 

 

 

BLC is easier to determine with a larger value (Initial value: 7)

 

 

Multi BLC Weight Preset

A0

06

05

CS

FF

 

 

 

 

Returns sensitivity during Multi BLC to factory defaults (Initial value: 7)

 

 

Multi BLC Weight Direct

A0

06

06

0p

CS

FF

 

 

 

p: Direct sensitivity settings 0-15 during Multi BLC (Initial value: 7)

 

 

Multi BLC Bright -

A0

06

07

00

CS

FF

 

 

 

Brightness settings during Multi BLC

 

 

 

Multi BLC Bright +

A0

06

07

01

CS

FF

 

 

 

Larger value increases brightness when determining BLC (Initial value: 7)

 

 

Multi BLC Bright Preset

A0

06

08

CS

FF

 

 

 

 

Returns brightness settings during Multi BLC to factory defaults (Initial value: 7)

 

 

Multi BLC Bright Direct

A0

06

09

0p

CS

FF

 

 

 

p: Direct brightness settings 0-15 during Multi BLC (Initial value: 7)

 

 

Center BLC ON

 

A0

06

0B

CS

FF

 

 

 

 

BLC center-weighted metering mode (Backlight compensates after measuring the light mainly in the

 

 

 

 

 

 

 

 

 

 

 

 

 

center.)

 

 

 

Center BLC Weight Preset

A0

06

0F

CS

FF

 

 

 

 

Returns sensitivity settings during Center BLC to factory defaults (Each initial value: 0)

 

 

Center BLC Weight Direct

A0

06

10

0p

0q

0r

0s

CS

FF

Sensitivity settings during Center BLC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

p: Top(0-7) q: Bottom(0-7) r: Left(0-7) s: Right(0-7) (Each initial value: 0)

 

 

Center BLC Area Preset

A0

06

12

CS

FF

 

 

 

 

Returns center area settings during Center BLC to factory defaults (Each initial value: 0)

 

 

Center BLC Area Direct

A0

06

13

0p

0q

0r

0s

CS

FF

Center area settings during Center BLC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

p: x-position(0-7) q: y-position(0-5) r: x-size(0-7)

s: y-size(0-5)

 

 

 

 

 

 

 

 

 

 

 

 

 

(Initial value: x-position: 2 y-position: 1 x-size: 3 y-size: 3)

 

 

 

 

 

 

 

 

 

 

 

 

 

*When x-size:0 y-size:0, it becomes 1 area.

 

 

 

Mask BLC ON

 

A0

06

15

CS

FF

 

 

 

 

BLC mask mode

 

 

 

Mask BLC Area Preset

A0

06

19

CS

FF

 

 

 

 

Return mask area settings during Mask BLC to factory defaults

 

 

Mask BLC Area Direct

A0

06

1D

0p

0q

0r

0s

0t

0u

Mask area settings during Mask BLC

(Note 1)

 

 

 

 

0v

0w

0x

0y

0z

0n

CS

FF

 

 

 

 

BLC ON

 

A0

06

33

CS

FF

 

 

 

 

Returns to the mode before BLC OFF only when BLC OFF

Shutter

 

Shutter Speed +

 

A0

07

0B

CS

FF

 

 

 

 

Increases shutter speed by one notch

 

Speed

 

Shutter Speed -

 

A0

07

0C

CS

FF

 

 

 

 

Decreases shutter speed by one notch

 

 

 

Shutter Speed Set long

A0

07

0E

0p

CS

FF

 

 

 

Shutter Speed Mode Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0: Prolonged exposure shutter mode, 1: Normal mode, 3: High speed shutter mode

 

 

Shutter Speed OFF

A0

07

0F

CS

FF

 

 

 

 

Same as Shutter Speed Set OFF

 

 

 

Shutter Long Direct

A0

07

11

0p

CS

FF

 

 

 

Shutter speed settings during prolonged exposure shutter mode

 

 

 

 

 

 

 

 

 

 

 

 

 

(0: x1, 1: x2, 2: x4, 3: x8, 4: x16, 5: x32)

 

 

 

Shutter Short Direct

A0

07

12

0p

CS

FF

 

 

 

Shutter speed settings during high speed shutter mode

 

 

 

 

 

 

 

 

 

 

 

 

 

(0: 1/60 (50), 1:1/100 (120), 2: 1/250, 3: 1/500, 4: 1/1000, 5: 1/2000, 6: 1/4000, 7: 1/10000)

 

 

Sense Up +

 

A0

07

1A

CS

FF

 

 

 

 

Increase electronic sensitivity settings

 

 

 

Sense Up -

 

A0

07

1B

CS

FF

 

 

 

 

 

 

 

 

Sense Up Direct

 

A0

07

1D

0p

CS

FF

 

 

 

p: Direct increased electronic sensitivity settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0: OFF, 1: x2, 2: x4, 3: x8, 4: x16, 5: x32)

 

 

 

ELS OFF

 

A0

07

28

CS

FF

 

 

 

 

Sets shutter speed to 1x (1/60) after saving

 

 

 

ELS ON

 

A0

07

29

CS

FF

 

 

 

 

Returns to electronic shutter speed saved by ELS OFF

Motion

 

Motion Detector OFF

A0

08

00

CS

FF

 

 

 

 

Motion sensor ON/OFF

 

Detector

 

Motion Detector ON

A0

08

01

CS

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motion Size Preset

A0

08

05

CS

FF

 

 

 

 

Returns detected motion size settings to factory defaults (Initial value: V-Size: 1, H-Size: 1)

 

 

Motion Size Direct

A0

08

06

0p

0q

CS

FF

 

 

Detected motion size settings p: V-Size (1-6) q: H-Size (1-8) (Initial value: V-Size: 1, H-Size: 1)

 

 

Alarm Sign OFF

 

A0

08

08

CS

FF

 

 

 

 

Display ON/OFF during alarm input

 

 

 

Alarm Sign ON

 

A0

08

09

CS

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Masking OFF

 

A0

08

0A

CS

FF

 

 

 

 

Mask area settings for motion detection ON/OFF

 

 

 

Masking ON

 

A0

08

0B

CS

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mask Area Preset

A0

08

0F

CS

FF

 

 

 

 

Returns mask area for motion detection to factory defaults

 

 

Mask Area Direct

A0

08

13

0p

0q

0r

0s

0t

0u

Mask area settings for motion detection

(Note 1)

 

 

 

 

0v

0w

0x

0y

0z

0n

CS

FF

 

 

 

 

Sensitivity Move +

A0

08

15

CS

FF

 

 

 

 

Motion detection sensitivity settings (Initial value: 5)

 

 

Sensitivity Move -

A0

08

16

CS

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensitivity Move Preset

A0

08

19

CS

FF

 

 

 

 

Returns motion detection sensitivity settings to factory defaults (Initial value: 5)

 

 

Sensitivity Move Direct

A0

08

1D

0p

CS

FF

 

 

 

p: Direct motion detection sensitivity settings 1-10 (Initial value: 5)

 

 

Sensitivity Y-Level +

A0

08

1F

CS

FF

 

 

 

 

Minimum brightness settings for motion detection (Initial value: 5)

 

 

Sensitivity Y-Level -

A0

08

20

CS

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensitivity Y-Level Peset

A0

08

23

CS

FF

 

 

 

 

Returns minimum brightness settings for motion detection to factory default (Initial value: 5)

 

 

Sensitivity Y-Level Direct

A0

08

27

0p

CS

FF

 

 

 

p: Direct minimum brightness settings for motion detection 1-10 (Initial value: 5)

 

 

Sensitivity Y-Differ +

A0

08

29

CS

FF

 

 

 

 

Brightness variation settings for undetected motion (Initial value: 5)

 

 

Sensitivity Y-Differ -

A0

08

2A

CS

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensitivity Y-Differ Preset

A0

08

2D

CS

FF

 

 

 

 

Returns brightness variation settings for undetected motion to factory defaults (Initial value: 5)

 

 

Sensitivity Y-Differ Direct

A0

08

31

0p

CS

FF

 

 

 

p: Direct brightness variation settings for undetected motion 1-10 (Initial value: 5)

 

 

Sensitivity Duration +

A0

08

33

CS

FF

 

 

 

 

Continuous movement time for motion detection (Initial value: 1)

 

 

Sensitivity Duration -

A0

08

34

CS

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensitivity Duration Preset

A0

08

37

CS

FF

 

 

 

 

Returns continuous movement time for motion detection to factory defaults (Initial value: 1)

 

 

Sensitivity Duration Direct

A0

08

3B

0p

CS

FF

 

 

 

p: Direct continuous movement time for motion detection 1-60 (Initial value: 1)

 

 

Motion Zoom

 

A0

08

3D

0p

CS

FF

 

 

 

p: Zoom magnification during motion detection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0: OFF, 1: x1.4, 2: x2, 3: x2.8, 4: x4, 5: x6)

 

 

 

Motion Interval

 

A0

08

42

0p

CS

FF

 

 

 

p: Interval time until the start of next detection during motion detection

 

 

 

 

 

 

 

 

 

 

 

 

 

(0: 5s, 1: 10s, 2: 15s, 3: 20s, 4: 30s, 5: 1m, 6: 2m, 7: 3m, 8: 4m, 9: 5m)

Sync

 

Sync INT

 

A0

09

00

CS

FF

 

 

 

 

Internal synchronization mode

 

 

 

Sync L-L

 

A0

09

01

CS

FF

 

 

 

 

Power supply synchronization mode

 

 

 

L-L Phase +

 

A0

09

0B

CS

FF

 

 

 

 

Synchronous phase settings for power source synchronization

 

 

L-L Phase -

 

A0

09

0C

CS

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L-L Phase Preset

A0

09

0F

CS

FF

 

 

 

 

Returns synchronous phase settings for power source synchronization to factory defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

(Initial value: 0)

 

 

 

L-L Phase Direct

A0

09

13

0p

0q

0r

CS

FF

 

pqr: Synchronous phase settings for power source synchronization

 

 

 

 

 

 

 

 

 

 

 

 

 

Direct 0-524 (NTSC) / 0-624 (PAL) (Each initial value: 0)

 

*1: Only MD400 

CS: Checksum

 

 

 

 

 

 

 

 

 

 

 

 

*2: Only MD300 

FF: Terminator

 

 

 

 

 

 

 

 

 

 

 

− 16 −

Image 17
Contents Technical Manual VVer Contents VCC-MD800/700/600/500 Series Parts Names and DimensionsDimensions VCC-MD400/MD300 Series Parts Names and DimensionsConnection of the Interface Board and Camera Unit Interface Board SpecificationsConnection External Synchronous Signals Input-Output Terminal Layout and SpecificationsInput-Output Terminal Descriptions FFC ComplianceCommunications Format Communications ProtocolDuring Settings Command During Query Command ACKDuring Query Command Other than ACK Communications FlowMWB Command List for MD800-500ATW BLC on BLC OFFELS OFF ELS onAGC ON/OFF AGCOFF SMART1Alarm OUT on Line OUT OFF Alarm Alarm OUT OFFOSD EepromCS FF Command List Query for MD800-500− 13 − − 14 − Command List for MD400 − 16 − − 17 − Burst on Level DAY ColorADJ Direct B Command List Query for MD400Model VCC-MD800/700/600/500/400/300 Example Motion Mask Area Settings Figure⁃⁃ Status Command 3 Only MD400 ⁃⁃ Status Command 2 Except for MD300⁃ ⁃ Status Command 6 Only MD800/700/600/500 ⁃⁃ Status Command 4 Only MD800/700/600/500⁃⁃ Status Command 5 Only MD800/700/600/500 ⁃⁃ When setting Sense UP Auto switch setting⁃⁃ When setting the motion setting to on When unable to set ⁃⁃ When setting V-RESO UP to on When unable to setModel Code Communications Protocol Zoom Control Function DescriptionsZoom Position Control ⁃⁃ Direct ⁃⁃ Tele/WideWhite Balance Control Focus ControlAGC Control Iris ControlShutter Speed Control Backlight Compensation Motion Detection 10 Day/Night Switch ControlAperture Setting the Mask Angle Area Mask Degree Set Privacy Mask Settings Display Area Ntsc PALDetails of the Mask Angle and Position Area Mask Degree SetSetting the Mask Position Area Mask Position Set Frequency that can be stabilized To clarify the image when using the stabilizerStabilizer Auto Pursuit Function Moving Distance Query CommandCommunications Error Camera Control Command TransmissionApplication Software RS-232C PortSpectral Sensitivity Characteristics Ntsc system SpecificationsPAL system Change history Change history