Function Descriptions
Optical Zoom Limit Settings
The optical zoom magnification can be limited using the Optical Zoom Tele Limiter command. The digital zoom cannot be used if the limit is set to the Tele side.
Digital Zoom
A maximum of 16x digital zoom can be set with the Digital Zoom Tele Limiter command. Together with the optical zoom, a maximum of 480x is possible, however, the resolution decreases.
Although the vertical resolution can be increased by enabling the
[2] Focus Control
Manual Focus
The manual focus can be operated using Far/Near or directly moving the focus to a specific position.
⁃⁃ Far /Near
Transmit the Far or Near command to execute the Far/Near operation at the speed configured by the Far/Near Speed command. The Stop command stops the operation. (The operation does not stop without transmitting the Stop command.)
The speed targets are as follows.
| Required Time (s) from Near End → Far End | ||||||
Settings |
| at the Near Limit 1m and Tele End | |||||
x36 | MD700 | x30 | MD500 | x22 | MD300 | ||
| |||||||
| MD800 | MD600 | MD400 | ||||
|
|
|
| ||||
1 |
| 19.7 |
| 16.0 |
| 19.0 | |
2 |
| 10.3 |
| 8.3 |
| 9.7 | |
3 |
| 4.4 |
| 3.6 |
| 6.6 | |
4 |
| 2.4 |
| 2.1 |
| 5.2 | |
⁃⁃ Direct
The Direct command can move the zoom lens to the specified focus lens position.
⁃⁃ Auto Focus
The Auto Focus ON command sets the mode to auto focus and automatically focuses on the subject if the subject moves. This mode is cancelled when the Manual Focus ON, Near, or Far command is used. Although the minimum focus distance is set to 1m by default, this can be changed by using the Near Limiter command. In addition, the sensitivity of the AF to the change in subject can be changed using the Auto Focus Sensitivity command and the focusing area can be changed using the Focus Area command.
One-Push Auto Focus
The auto focus can be moved only once using the One Push Trigger command. The mode prior to starting the auto focus is retained after focusing.
Focus Lens Offset
When covering a camera, such as the dome camera with a cover or similar, the refraction of the light due to the cover changes the OPL. This may result in close subjects being out of focus when using a powerful zoom.
In that case, it is necessary to move the range of motion of the focus lens depending on the change in OPL.
Validate the Offset using the Cover Offset ON command and transmit a Cover Offset Level command so that subjects that are at approximately 1m TELE edge (When the Near Limit is 1m) are in focus.
In the same way that 0 sets the level to OFF, the larger the number, the greater the offset.
[3] White Balance Control
⁃⁃ ATW
Auto Trace White Balance.
・SMART ATW
This mode controls retracing of ATW according
to the size of
In case the
Also, the retracing speed is slower than that of normal ATW mode.
*This mode is valid when WB mode is set to ATW.
⁃⁃ AWC
The
In addition, after executing the One Push Trigger command, the mode returns to the previous mode by executing the AWC Reset command.
⁃⁃ 3200K
Color temperature 3200K fixed mode.
⁃⁃ 5600K
Color temperature 5600K fixed mode.
⁃⁃ FLUO
Color temperature 4200K fixed mode.
⁃⁃ MWB
Manual White Balance. The R and B gains can each be configured to a range of 0 to 255.